+ make -C testsuite/special/FmuExportCrossCompile/ test
make: Entering directory '/var/lib/jenkins1/ws/OpenModelica_master_2/testsuite/special/FmuExportCrossCompile'
rm -rf *.json *.xml *.html *.fmu* *.c *.makefile *.log *.o *.opt *.libs *.h *.mat *.csv
rm -f BouncingBall FmuExportCrossCompile RoomHeating_OM_RH WaterTank_Control WaterTank_TestSingleWaterTank
rm -rf CMakeCrossCompile/ Test_FMUs/
make fmuExportCrossCompile
make[1]: Entering directory '/var/lib/jenkins1/ws/OpenModelica_master_2/testsuite/special/FmuExportCrossCompile'
HOME=/var/lib/jenkins1/ws/OpenModelica_master_2/testsuite/special/FmuExportCrossCompile/../../../libraries/ ../../../build/bin/omc fmuExportCrossCompile.mos
""
""
""
""
""
{"x86_64-apple-darwin15 docker run docker.openmodelica.org/osxcross-omsimulator:v2.0", "arm-linux-gnueabihf docker run docker.openmodelica.org/armcross-omsimulator:v2.0", "x86_64-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13", "i686-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13-i386", "x86_64-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0", "i686-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0"}
FmuExportCrossCompile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: Modelica requested package Complex of version 3.2.3. Complex 4.1.0 is used instead which states that it is fully compatible without conversion script needed.
Notification: Modelica requested package ModelicaServices of version 3.2.3. ModelicaServices 4.1.0 is used instead which states that it is fully compatible without conversion script needed.
Notification: The Makefile build for FMUs is deprecated and will be removed in a future version of OpenModelica. Use "--fmuCMakeBuild=true".
record SimulationResult
resultFile = "/var/lib/jenkins1/ws/OpenModelica_master_2/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile_res.csv",
simulationOptions = "startTime = 0.0, stopTime = 0.45, numberOfIntervals = 2000, tolerance = 1e-6, method = 'euler', fileNamePrefix = 'FmuExportCrossCompile', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
messages = "LOG_SUCCESS | info | The initialization finished successfully without homotopy method.
LOG_SUCCESS | info | The simulation finished successfully.
",
timeFrontend = 0.107645603,
timeBackend = 0.004369932,
timeSimCode = 0.0010927670000000001,
timeTemplates = 0.003910787000000001,
timeCompile = 0.672250295,
timeSimulation = 0.022975198000000002,
timeTotal = 0.812421579
end SimulationResult;
"Notification: Modelica requested package Complex of version 3.2.3. Complex 4.1.0 is used instead which states that it is fully compatible without conversion script needed.
Notification: Modelica requested package ModelicaServices of version 3.2.3. ModelicaServices 4.1.0 is used instead which states that it is fully compatible without conversion script needed.
"
true
""
"/var/lib/jenkins1/ws/OpenModelica_master_2/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile.fmu"
RoomHeating_OM_RH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: Modelica requested package Complex of version 3.2.3. Complex 4.1.0 is used instead which states that it is fully compatible without conversion script needed.
Notification: Modelica requested package ModelicaServices of version 3.2.3. ModelicaServices 4.1.0 is used instead which states that it is fully compatible without conversion script needed.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->Show additional information from the initialization process, in OMNotebook call setCommandLineOptions("-d=initialization").
Notification: The Makefile build for FMUs is deprecated and will be removed in a future version of OpenModelica. Use "--fmuCMakeBuild=true".
record SimulationResult
resultFile = "/var/lib/jenkins1/ws/OpenModelica_master_2/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH_res.csv",
simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-6, method = 'euler', fileNamePrefix = 'RoomHeating_OM_RH', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
messages = "LOG_ASSERT | warning | [/var/lib/jenkins1/ws/OpenModelica_master_2/testsuite/special/FmuExportCrossCompile/RoomHeating_OM.mo:69:5-69:117:writable]
| | | | The following assertion has been violated during initialization at time 0.000000
| | | | ((fanspeed >= 0.01)) --> \"UTRC-FCU-002: FCU air damper should be opened at least 0.10.\"
LOG_SUCCESS | info | The initialization finished successfully without homotopy method.
LOG_SUCCESS | info | The simulation finished successfully.
",
timeFrontend = 0.528025727,
timeBackend = 0.012253803,
timeSimCode = 0.0021876960000000003,
timeTemplates = 0.005576088000000001,
timeCompile = 0.765476084,
timeSimulation = 0.05606384699999989,
timeTotal = 1.369690763
end SimulationResult;
"Notification: Modelica requested package Complex of version 3.2.3. Complex 4.1.0 is used instead which states that it is fully compatible without conversion script needed.
Notification: Modelica requested package ModelicaServices of version 3.2.3. ModelicaServices 4.1.0 is used instead which states that it is fully compatible without conversion script needed.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->Show additional information from the initialization process, in OMNotebook call setCommandLineOptions(\"-d=initialization\").
"
true
""
"/var/lib/jenkins1/ws/OpenModelica_master_2/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH.fmu"
WaterTank_Control
2380a4b21371bb88f54d60c89c1b20b4423181591737710cde8e0dd82d02651b
be4e3a88769dcf4d801b6d72bb925116ba6819718e4294fec2f8292909cb33df
47787e6dea0e093d5c6ab89e73df78c3cecc16323811676253d10a33a816aa0d
b5448db00b82646ca298638bdc0b90b5343f367c60fc018d9d8fd5de7cec052a
d31e2f4a55f492e2dc2e4c5e8bc0fa6c57f8870fcb3ad41bf21561ba40985b68
2d6ed1fca4880653b7d50b6fa26f9278877cad51b7e12d71601a8a3276ac0cb9
8dde6c44147c0e8f861f358d7413b30f7529ccd75948007c9a9fe01c1d60ac34
f950a8f08e822b2d5828d727cc0b8ff734c05cbb2a4431069bed75952b4ac1dc
69973156690e50e753079f0a7129d572b61f8325c2cc068bee2c9bb448106e75
680876c44da9eacdf0dbe22392cc4eff688fbcc587acd1ba910d97849e4c15dc
bde05fbbdcaaa1bcc544f78a2edc85e94ae76af0af69b3896dce833d5502bf86
6da0954376427118569851966c9b43ac6706c2bace4ee6bf46271d89775d6d4e
Notification: Modelica requested package Complex of version 3.2.3. Complex 4.1.0 is used instead which states that it is fully compatible without conversion script needed.
Notification: Modelica requested package ModelicaServices of version 3.2.3. ModelicaServices 4.1.0 is used instead which states that it is fully compatible without conversion script needed.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->Show additional information from the initialization process, in OMNotebook call setCommandLineOptions("-d=initialization").
Notification: The Makefile build for FMUs is deprecated and will be removed in a future version of OpenModelica. Use "--fmuCMakeBuild=true".
record SimulationResult
resultFile = "/var/lib/jenkins1/ws/OpenModelica_master_2/testsuite/special/FmuExportCrossCompile/WaterTank_Control_res.csv",
simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-6, method = 'euler', fileNamePrefix = 'WaterTank_Control', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
messages = "LOG_SUCCESS | info | The initialization finished successfully without homotopy method.
LOG_SUCCESS | info | The simulation finished successfully.
",
timeFrontend = 0.11611918800000001,
timeBackend = 0.0032809180000000003,
timeSimCode = 8.28072e-4,
timeTemplates = 0.0037723490000000004,
timeCompile = 0.700323008,
timeSimulation = 0.018774041,
timeTotal = 0.843245997
end SimulationResult;
"Notification: Modelica requested package Complex of version 3.2.3. Complex 4.1.0 is used instead which states that it is fully compatible without conversion script needed.
Notification: Modelica requested package ModelicaServices of version 3.2.3. ModelicaServices 4.1.0 is used instead which states that it is fully compatible without conversion script needed.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->Show additional information from the initialization process, in OMNotebook call setCommandLineOptions(\"-d=initialization\").
"
true
""
"/var/lib/jenkins1/ws/OpenModelica_master_2/testsuite/special/FmuExportCrossCompile/WaterTank_Control.fmu"
WaterTank_TestSingleWaterTank
b81383de993b46a35c1a05f9137a3cc5bd515543bff0ca809688f485a9ba2f5f
2a4872f4b2f47f92bc0357ed931a4d0bfab8f8f8781871a87bc42080f38e4286
02a075e32ce98d8b3fd2b7b8eac15fb50e88bb6d7f18cc949075bdc4ca8ed9af
556469be9443523dca3531770ded7e32acac22c9c59c497e7941f9b71e21fb2c
c357955f93875cbc743604569be22f2a44350bbc715758c324504adaf82a7dbc
fb68fe4c7fd16fc5514b689b911e36d097d18b9583ffee9e47fc034c4fb57899
bd411bb610f9fa407a27e75c3a7d4a875898b21fc242084a8d8fbc3517c3994f
e11814669a2def8140fd2a3edf5c253863be56f69283cb96623886b0718f674f
fee51ed601910dcc3a7240dc366d0687439f5166482c876a0314e1644164294b
99b6474cc6ba3d0c84b8aa4e54adaf9817f35cd9a258732b6316592112be171c
d29b0e90daec1ef2d3afeee62c74a2d164f57c7398a38cc1294ad176075faade
d465f8cb35a147035e482259dda3442413b4c0932a3bb3c785afc3c0e935038f
Notification: Modelica requested package Complex of version 3.2.3. Complex 4.1.0 is used instead which states that it is fully compatible without conversion script needed.
Notification: Modelica requested package ModelicaServices of version 3.2.3. ModelicaServices 4.1.0 is used instead which states that it is fully compatible without conversion script needed.
[/var/lib/jenkins1/ws/OpenModelica_master_2/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation tank.valvecontrol <> 0.0, <> on Real numbers is only allowed inside functions.
[/var/lib/jenkins1/ws/OpenModelica_master_2/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation tank.valvecontrol <> 0.0, <> on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->Show additional information from the initialization process, in OMNotebook call setCommandLineOptions("-d=initialization").
Notification: The Makefile build for FMUs is deprecated and will be removed in a future version of OpenModelica. Use "--fmuCMakeBuild=true".
record SimulationResult
resultFile = "/var/lib/jenkins1/ws/OpenModelica_master_2/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank_res.csv",
simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-6, method = 'euler', fileNamePrefix = 'WaterTank_TestSingleWaterTank', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
messages = "LOG_SUCCESS | info | The initialization finished successfully without homotopy method.
LOG_SUCCESS | info | The simulation finished successfully.
",
timeFrontend = 0.110682125,
timeBackend = 0.006416691,
timeSimCode = 0.001493984,
timeTemplates = 0.004478054,
timeCompile = 0.74316905,
timeSimulation = 0.054132946,
timeTotal = 0.920505426
end SimulationResult;
"Notification: Modelica requested package Complex of version 3.2.3. Complex 4.1.0 is used instead which states that it is fully compatible without conversion script needed.
Notification: Modelica requested package ModelicaServices of version 3.2.3. ModelicaServices 4.1.0 is used instead which states that it is fully compatible without conversion script needed.
[/var/lib/jenkins1/ws/OpenModelica_master_2/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation tank.valvecontrol <> 0.0, <> on Real numbers is only allowed inside functions.
[/var/lib/jenkins1/ws/OpenModelica_master_2/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation tank.valvecontrol <> 0.0, <> on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->Show additional information from the initialization process, in OMNotebook call setCommandLineOptions(\"-d=initialization\").
"
true
""
"/var/lib/jenkins1/ws/OpenModelica_master_2/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank.fmu"
BouncingBall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: Modelica requested package Complex of version 3.2.3. Complex 4.1.0 is used instead which states that it is fully compatible without conversion script needed.
Notification: Modelica requested package ModelicaServices of version 3.2.3. ModelicaServices 4.1.0 is used instead which states that it is fully compatible without conversion script needed.
Notification: The Makefile build for FMUs is deprecated and will be removed in a future version of OpenModelica. Use "--fmuCMakeBuild=true".
record SimulationResult
resultFile = "/var/lib/jenkins1/ws/OpenModelica_master_2/testsuite/special/FmuExportCrossCompile/BouncingBall_res.csv",
simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-6, method = 'euler', fileNamePrefix = 'BouncingBall', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
messages = "LOG_SUCCESS | info | The initialization finished successfully without homotopy method.
LOG_SUCCESS | info | The simulation finished successfully.
",
timeFrontend = 0.5120452950000001,
timeBackend = 0.004523298,
timeSimCode = 0.0012811270000000002,
timeTemplates = 0.0036849990000000004,
timeCompile = 0.7136522519999999,
timeSimulation = 0.023524376000000003,
timeTotal = 1.258836488
end SimulationResult;
"Notification: Modelica requested package Complex of version 3.2.3. Complex 4.1.0 is used instead which states that it is fully compatible without conversion script needed.
Notification: Modelica requested package ModelicaServices of version 3.2.3. ModelicaServices 4.1.0 is used instead which states that it is fully compatible without conversion script needed.
"
true
""
"/var/lib/jenkins1/ws/OpenModelica_master_2/testsuite/special/FmuExportCrossCompile/BouncingBall.fmu"
unzip -q FmuExportCrossCompile.fmu -d FmuExportCrossCompile.fmutmp
make check-FmuExportCrossCompile-files
make[2]: Entering directory '/var/lib/jenkins1/ws/OpenModelica_master_2/testsuite/special/FmuExportCrossCompile'
FmuExportCrossCompile.fmutmp/binaries/win32/FmuExportCrossCompile.dll: PE32 executable (DLL) (console) Intel 80386, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/win64/FmuExportCrossCompile.dll: PE32+ executable (DLL) (console) x86-64, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/darwin64/FmuExportCrossCompile.dylib: Mach-O 64-bit x86_64 dynamically linked shared library, flags:<NOUNDEFS|DYLDLINK|TWOLEVEL|NO_REEXPORTED_DYLIBS>
FmuExportCrossCompile.fmutmp/binaries/linux32/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, Intel 80386, version 1 (SYSV), dynamically linked, BuildID[sha1]=d2f28d00daaeea7abc14dd654c7805eabf5d4931, not stripped
FmuExportCrossCompile.fmutmp/binaries/linux64/FmuExportCrossCompile.so: ELF 64-bit LSB shared object, x86-64, version 1 (SYSV), dynamically linked, BuildID[sha1]=df14419751cdf0e21b4fde0920f1f5fe42dafca6, not stripped
FmuExportCrossCompile.fmutmp/binaries/arm-linux-gnueabihf/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, ARM, EABI5 version 1 (SYSV), dynamically linked, BuildID[sha1]=24f8b7f1bccc1b3d6438b7341f62c3967b487d89, not stripped
make[2]: Leaving directory '/var/lib/jenkins1/ws/OpenModelica_master_2/testsuite/special/FmuExportCrossCompile'
make[1]: Leaving directory '/var/lib/jenkins1/ws/OpenModelica_master_2/testsuite/special/FmuExportCrossCompile'
make CMakeCrossCompile
make[1]: Entering directory '/var/lib/jenkins1/ws/OpenModelica_master_2/testsuite/special/FmuExportCrossCompile'
HOME=/var/lib/jenkins1/ws/OpenModelica_master_2/testsuite/special/FmuExportCrossCompile/../../../libraries/ ../../../build/bin/omc CMakeCrossCompile.mos
0
"/var/lib/jenkins1/ws/OpenModelica_master_2/testsuite/special/FmuExportCrossCompile/CMakeCrossCompile"
{"x86_64-apple-darwin docker run multiarch/crossbuild", "x86_64-linux-gnu docker run multiarch/crossbuild", "i686-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13-i386", "x86_64-w64-mingw32 docker run multiarch/crossbuild", "i686-w64-mingw32 docker run multiarch/crossbuild"}
397ba063b56cdb5eacaa1487d26bf6f41a62d3e1c6e30778413b98a325f9a7c8
6cbc1e89a07e83ee04bc0035fbf6e1ab685e5c0ec3f28bc1c61a73a0ab4b857d
f39b241153721949d755d091cd57aace491fe4cc30fc88a31a00bfcc4ae20ca5
48daf688a5e212c0538fb73c5c6c3d52a8bd59b1cba5e8cc228304e16b616ad5
f0ba4f65752bed3ae29b4344438940a0ceda8df8fd632be2c3136a06c51b6c2e
2859d26b6647d9228cd93ac6eb1b140a0dbd20f4200e41587441a50ec5aba67c
8ee6949384143ab67e82e656ab08cbd7dfaf771f0cace141f4c9371971c83a90
2feb75c134ae9e72b63015704e90778c59d0cdbe1c75496764b79d210e5ed7d5
4fbe2fd92dbb95f8af41304e5a9586ad14d47669d01791a0bc8d0d562aab9a36
a12f167b8124dc8f8581791d580b7c87d991a199035ea86a9fadbfa244dfc036
"/var/lib/jenkins1/ws/OpenModelica_master_2/testsuite/special/FmuExportCrossCompile/CMakeCrossCompile/Modelica.Mechanics.MultiBody.Examples.Elementary.Pendulum.fmu"
""
unzip -qq CMakeCrossCompile/Modelica.Mechanics.MultiBody.Examples.Elementary.Pendulum.fmu -d CMakeCrossCompile/Pendulum_FMU/
make check-CMakeCrossCompile-files
make[2]: Entering directory '/var/lib/jenkins1/ws/OpenModelica_master_2/testsuite/special/FmuExportCrossCompile'
CMakeCrossCompile/Pendulum_FMU/binaries/win32/Modelica_Mechanics_MultiBody_Examples_Elementary_Pendulum.dll: PE32 executable (DLL) (console) Intel 80386, for MS Windows
CMakeCrossCompile/Pendulum_FMU/binaries/win64/Modelica_Mechanics_MultiBody_Examples_Elementary_Pendulum.dll: PE32+ executable (DLL) (console) x86-64, for MS Windows
CMakeCrossCompile/Pendulum_FMU/binaries/darwin64/Modelica_Mechanics_MultiBody_Examples_Elementary_Pendulum.dylib: Mach-O 64-bit x86_64 dynamically linked shared library, flags:<NOUNDEFS|DYLDLINK|TWOLEVEL|NO_REEXPORTED_DYLIBS>
CMakeCrossCompile/Pendulum_FMU/binaries/linux32/Modelica_Mechanics_MultiBody_Examples_Elementary_Pendulum.so: ELF 32-bit LSB shared object, Intel 80386, version 1 (SYSV), dynamically linked, BuildID[sha1]=86d1a8e112a44e50b832ec1e96bffd43b34929d6, with debug_info, not stripped
CMakeCrossCompile/Pendulum_FMU/binaries/linux64/Modelica_Mechanics_MultiBody_Examples_Elementary_Pendulum.so: ELF 64-bit LSB shared object, x86-64, version 1 (SYSV), dynamically linked, BuildID[sha1]=8457f3b3f897b5c21c92ef06bbe6dd55e8b74fff, with debug_info, not stripped
make[2]: Leaving directory '/var/lib/jenkins1/ws/OpenModelica_master_2/testsuite/special/FmuExportCrossCompile'
make[1]: Leaving directory '/var/lib/jenkins1/ws/OpenModelica_master_2/testsuite/special/FmuExportCrossCompile'
make: Leaving directory '/var/lib/jenkins1/ws/OpenModelica_master_2/testsuite/special/FmuExportCrossCompile'