Skip to content

Console Output

+ make -C testsuite/special/FmuExportCrossCompile/ test
make: Entering directory '/var/lib/jenkins/ws/OpenModelica_maintenance_v1.16/testsuite/special/FmuExportCrossCompile'
rm -rf *.json *.xml *.html *.fmu* *.c *.makefile *.log *.o *.libs *.h *.mat *.csv Test_FMUs
HOME=/var/lib/jenkins/ws/OpenModelica_maintenance_v1.16/testsuite/special/FmuExportCrossCompile/../../libraries-for-testing/ ../../../build/bin/omc fmuExportCrossCompile.mos

""

""

""

""

""
{"x86_64-apple-darwin15 docker run docker.openmodelica.org/osxcross-omsimulator:v2.0","arm-linux-gnueabihf docker run docker.openmodelica.org/armcross-omsimulator:v2.0","x86_64-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13","i686-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13-i386","x86_64-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0","i686-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0"}
FmuExportCrossCompile
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record SimulationResult
    resultFile = "/var/lib/jenkins/ws/OpenModelica_maintenance_v1.16/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 0.45, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'FmuExportCrossCompile', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.185073395,
    timeBackend = 0.003019029,
    timeSimCode = 0.09586575200000001,
    timeTemplates = 0.002510305,
    timeCompile = 0.5867752460000001,
    timeSimulation = 0.034536724,
    timeTotal = 0.907995074
end SimulationResult;
""

"/var/lib/jenkins/ws/OpenModelica_maintenance_v1.16/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile.fmu"


RoomHeating_OM_RH

1ce8c4e9ebee3dd51daecc0625de7324911f05dcfcef8f148628ecc2e7b14539
7c8b078d583926bb1bede0e49808d5937078d0704bce3ec609b7b33e48e45467
8ce9dea9878b9efb2036748c5aabf352ae17d7e39bc7c9d62b8dd81d3a793484
31e8356b57db4c83582481000c07b46ddb77d6f248fe4a7d994decf89459b902
6b8d22c2fa3da69eff6b4a045b2f30855a784a9c8018fd75a3f94500a429d794
769ed41707e02461798bb7cb6e4f207d243661dc9c91b0156759eda54276d188
aca72422d5fe893ee79ab75314a4c002ffff15df2f2fa9459e05960fbf464ac6
9e6e1fbd3c3ca4ae301c124e241ee1fe993ac5885cea88a1dc4fb3d65640f64c
f7e370825b071b03c7e9d59448a131d134748fa83f4ab2d3d65751de29301c8d
00d19eff45e5cd0298d34ee8e30a7a949e43840a6828ea24e53e04709e3bfff1
e017537ca192ec04dea5105bf8ca1c90bd7c2ff9fb03646b1f3d2d0b61d05da9
1ee715a8802fa1b2d06ce49c2ee997f0dacc786545daaf9e728f6b14e10b298d
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins/ws/OpenModelica_maintenance_v1.16/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'RoomHeating_OM_RH', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "assert            | warning | The following assertion has been violated during initialization at time 0.000000
|                 | |       | fanspeed >= 0.01
assert            | warning | UTRC-FCU-002: FCU air damper should be opened at least 0.10.
LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.30193246,
    timeBackend = 0.009965304000000001,
    timeSimCode = 0.002091397,
    timeTemplates = 0.003228343,
    timeCompile = 0.567629864,
    timeSimulation = 0.060862348,
    timeTotal = 0.9458666489999999
end SimulationResult;
"Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions(\"-d=initialization\").
"

"/var/lib/jenkins/ws/OpenModelica_maintenance_v1.16/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH.fmu"


WaterTank_Control
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record SimulationResult
    resultFile = "/var/lib/jenkins/ws/OpenModelica_maintenance_v1.16/testsuite/special/FmuExportCrossCompile/WaterTank_Control_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'WaterTank_Control', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.21048822,
    timeBackend = 0.006895709000000001,
    timeSimCode = 0.001301702,
    timeTemplates = 0.002620445,
    timeCompile = 0.572440392,
    timeSimulation = 0.032198648,
    timeTotal = 0.826109172
end SimulationResult;
""

"/var/lib/jenkins/ws/OpenModelica_maintenance_v1.16/testsuite/special/FmuExportCrossCompile/WaterTank_Control.fmu"


WaterTank_TestSingleWaterTank
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[/var/lib/jenkins/ws/OpenModelica_maintenance_v1.16/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
[/var/lib/jenkins/ws/OpenModelica_maintenance_v1.16/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins/ws/OpenModelica_maintenance_v1.16/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'WaterTank_TestSingleWaterTank', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.296781805,
    timeBackend = 0.011466822,
    timeSimCode = 0.002639861,
    timeTemplates = 0.002453874,
    timeCompile = 0.6000587079999999,
    timeSimulation = 0.045433362,
    timeTotal = 0.958973484
end SimulationResult;
"[/var/lib/jenkins/ws/OpenModelica_maintenance_v1.16/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
[/var/lib/jenkins/ws/OpenModelica_maintenance_v1.16/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions(\"-d=initialization\").
"

"/var/lib/jenkins/ws/OpenModelica_maintenance_v1.16/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank.fmu"


BouncingBall

eaa0c235ddd143430bff08b1f8e57b4a61ca45860f7301c6d3255b67393063ab
18533254c0c058af3c32bb7015770cb7cb7c45ad32d8a25b60d606c7c1de25eb
7885fe108206968a12aee9945ce00744daf0b42d96ccf939742d619226daac6a
574300d81f66d293d77cee51a89773693ff53c2e954e2bf7dd263e2a591cc9a0
cf32294f6b2551ac8a69dab9ad4af7d0c12f6a7021d222f8ab0db3ad134ecf59
66f8d580c2cce189c3129c1712dc617d302578ec127849df3b5cee4f90b2eedc
424b51a1bd52cc6ee400674c26c2ceca027bee2ed57190e03ddfaba0b2ae0da1
798b5f88f36d66ee01aded9dcb501f6bf9f707447502a077cc37e1b4330ac28c
abeea30cfae3456b5d173cffae8ead0b3a69492bd587bc8e315a2884db79a10c
db0018b86547363879272778060c2117a6048833f0ba565d3bebbb7bc9c09e74
9fc5f2483c377ff6fe23eb32eadcdfcd1cf4ff2383b6be311e28bbf3c8a4265e
607d5e1eea27be0df2f3c1546ac1f1d663c0f0029d30e6ffa13ec42fea93c5b9


record SimulationResult
    resultFile = "/var/lib/jenkins/ws/OpenModelica_maintenance_v1.16/testsuite/special/FmuExportCrossCompile/BouncingBall_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'BouncingBall', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.299722192,
    timeBackend = 0.004254871,
    timeSimCode = 0.001232628,
    timeTemplates = 0.002118426,
    timeCompile = 0.600706696,
    timeSimulation = 0.03450795,
    timeTotal = 0.9426675
end SimulationResult;
""

"/var/lib/jenkins/ws/OpenModelica_maintenance_v1.16/testsuite/special/FmuExportCrossCompile/BouncingBall.fmu"



unzip -q FmuExportCrossCompile.fmu -d FmuExportCrossCompile.fmutmp
make check-files
make[1]: Entering directory '/var/lib/jenkins/ws/OpenModelica_maintenance_v1.16/testsuite/special/FmuExportCrossCompile'
FmuExportCrossCompile.fmutmp/binaries/win32/FmuExportCrossCompile.dll: PE32 executable (DLL) (console) Intel 80386, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/win64/FmuExportCrossCompile.dll: PE32+ executable (DLL) (console) x86-64, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/darwin64/FmuExportCrossCompile.dylib: Mach-O 64-bit x86_64 dynamically linked shared library, flags:<NOUNDEFS|DYLDLINK|TWOLEVEL|NO_REEXPORTED_DYLIBS>
FmuExportCrossCompile.fmutmp/binaries/linux32/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, Intel 80386, version 1 (SYSV), dynamically linked, BuildID[sha1]=6aa06ae459df15adb09a21d6d806e6d8625efb81, not stripped
FmuExportCrossCompile.fmutmp/binaries/linux64/FmuExportCrossCompile.so: ELF 64-bit LSB shared object, x86-64, version 1 (SYSV), dynamically linked, BuildID[sha1]=a9fccb80f95d42ebde5e0149f9d9aabf6b6c5e72, not stripped
FmuExportCrossCompile.fmutmp/binaries/arm-linux-gnueabihf/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, ARM, EABI5 version 1 (SYSV), dynamically linked, BuildID[sha1]=3fcd4350c5259c528e0c8f4bdae8be94502eabe1, not stripped
make[1]: Leaving directory '/var/lib/jenkins/ws/OpenModelica_maintenance_v1.16/testsuite/special/FmuExportCrossCompile'
make: Leaving directory '/var/lib/jenkins/ws/OpenModelica_maintenance_v1.16/testsuite/special/FmuExportCrossCompile'