Skip to content

Failed

simulation_modelica_commonSubExp.ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1.mos (from (result.xml))

Failing for the past 152 builds (Since #3553 )
Took 25 sec.

Stacktrace

Output mismatch (see stdout for details)

Standard Output

 + ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1                         ... equation mismatch [time: 24]

==== Log C:\WINDOWS\TEMP/omc-rtest-OpenModelica/simulation/modelica/commonSubExp/ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1.mos_temp7354/log-ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1.mos
true
""
true
"Warning: Requested package Modelica of version 3.2.3, but this package was already loaded with version 3.2.1. There are no conversion annotations for this version but 3.2.3 is newer than 3.2.1. There is a possibility that 3.2.1 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
"
record SimulationResult
    resultFile = "ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1_res.mat",
    simulationOptions = "startTime = 0.0, stopTime = 1000.0, numberOfIntervals = 500, tolerance = 1e-6, method = 'dassl', fileNamePrefix = 'ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1', options = '', outputFormat = 'mat', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
"
end SimulationResult;
"Warning: Requested package Modelica of version 3.2.3, but this package was already loaded with version 3.2.1. There are no conversion annotations for this version but 3.2.3 is newer than 3.2.1. There is a possibility that 3.2.1 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
[ThermoSysPro 3.2.0/WaterSteam/Connectors.mo:3:3-43:17:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidInlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
[ThermoSysPro 3.2.0/WaterSteam/Connectors.mo:87:3-127:18:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidOutlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
[ThermoSysPro 3.2.0/ElectroMechanics/Connectors.mo:3:3-36:24:writable] Warning: Connector .ThermoSysPro.ElectroMechanics.Connectors.MechanichalTorque is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0).
[ThermoSysPro 3.2.0/Properties/WaterSteam/Common.mo:1494:3-1528:30:writable] Warning: sat.T was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/Properties/WaterSteam/Common.mo:1494:3-1528:30:writable] Warning: sat.dpT was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/Properties/WaterSteam/Common.mo:1552:3-1581:34:writable] Warning: sat.T was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/Properties/WaterSteam/Common.mo:1552:3-1581:34:writable] Warning: sat.dpT was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/Properties/WaterSteam/Common.mo:1552:3-1581:34:writable] Warning: sat.cpt was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/Properties/WaterSteam/Common.mo:1552:3-1581:34:writable] Warning: sat.vt was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/Properties/WaterSteam/Common.mo:1552:3-1581:34:writable] Warning: sat.vp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/Properties/WaterSteam/Common.mo:1552:3-1581:34:writable] Warning: sat.vtt was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/Properties/WaterSteam/Common.mo:1552:3-1581:34:writable] Warning: sat.vpp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/Properties/WaterSteam/Common.mo:1552:3-1581:34:writable] Warning: sat.vtp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/Properties/WaterSteam/IF97_packages.mo:1089:9-1089:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/Properties/WaterSteam/IF97_packages.mo:851:9-851:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/Properties/WaterSteam/IF97_packages.mo:784:9-784:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/Properties/WaterSteam/Common.mo:162:3-214:22:writable] Warning: pro.x was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/Properties/WaterSteam/Common.mo:252:3-295:26:writable] Warning: pro.duph was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/Properties/WaterSteam/Common.mo:252:3-295:26:writable] Warning: pro.duhp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/Properties/WaterSteam/Common.mo:252:3-295:26:writable] Warning: pro.x was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/Properties/WaterSteam/Common.mo:1270:3-1340:18:writable] Warning: pro.duph was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/Properties/WaterSteam/Common.mo:1270:3-1340:18:writable] Warning: pro.duhp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/Properties/C3H3F5/C3H3F5_Ph.mo:2:1-131:14:writable] Warning: pro.u was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/Properties/C3H3F5/C3H3F5_Ph.mo:2:1-131:14:writable] Warning: pro.cp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/Properties/C3H3F5/C3H3F5_Ph.mo:2:1-131:14:writable] Warning: pro.ddhp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/Properties/C3H3F5/C3H3F5_Ph.mo:2:1-131:14:writable] Warning: pro.ddph was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/Properties/C3H3F5/C3H3F5_Ph.mo:2:1-131:14:writable] Warning: pro.duph was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/Properties/C3H3F5/C3H3F5_Ph.mo:2:1-131:14:writable] Warning: pro.duhp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/Properties/WaterSteamSimple/prop4_Ph_der.mo:179:3-182:49:writable] Warning: du1satp_der was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/Properties/WaterSteamSimple/prop4_Ph_der.mo:179:3-182:49:writable] Warning: du2satp_der was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/Properties/WaterSteamSimple/prop4_Ph.mo:76:3-76:60:writable] Warning: dh1satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/Properties/WaterSteamSimple/prop4_Ph.mo:76:3-76:60:writable] Warning: dh2satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/WaterSteam/Connectors.mo:87:3-127:18:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidOutlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
[ThermoSysPro 3.2.0/WaterSteam/Connectors.mo:3:3-43:17:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidInlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
[ThermoSysPro 3.2.0/ElectroMechanics/Connectors.mo:3:3-36:24:writable] Warning: Connector .ThermoSysPro.ElectroMechanics.Connectors.MechanichalTorque is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0).
[ThermoSysPro 3.2.0/WaterSteam/Connectors.mo:87:3-127:18:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidOutlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
[ThermoSysPro 3.2.0/WaterSteam/Connectors.mo:3:3-43:17:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidInlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
[ThermoSysPro 3.2.0/WaterSteam/Connectors.mo:87:3-127:18:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidOutlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
[ThermoSysPro 3.2.0/ElectroMechanics/Connectors.mo:3:3-36:24:writable] Warning: Connector .ThermoSysPro.ElectroMechanics.Connectors.MechanichalTorque is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0).
[ThermoSysPro 3.2.0/WaterSteam/Connectors.mo:3:3-43:17:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidInlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
"
1

"Error: Failed to open simulation result ReferenceFiles/ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1.mat: No such file or directory
Error: Error opening reference file: ReferenceFiles/ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1.mat
"
Files not equal!

0
'' 
Equation mismatch: diff says: 
--- "C:\\WINDOWS\\TEMP/omc-rtest-OpenModelica/simulation/modelica/commonSubExp/ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1.mos_temp7354/equations-expected"2024-04-18 16:37:23.244504300 +0200
+++ "C:\\WINDOWS\\TEMP/omc-rtest-OpenModelica/simulation/modelica/commonSubExp/ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1.mos_temp7354/equations-got"2024-04-18 16:37:47.906504400 +0200
@@ -3,11 +3,11 @@
 true
 "Warning: Requested package Modelica of version 3.2.3, but this package was already loaded with version 3.2.1. There are no conversion annotations for this version but 3.2.3 is newer than 3.2.1. There is a possibility that 3.2.1 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
 "
 record SimulationResult
 resultFile = "ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1_res.mat",
-simulationOptions = "startTime = 0.0, stopTime = 1000.0, numberOfIntervals = 500, tolerance = 1e-06, method = 'dassl', fileNamePrefix = 'ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1', options = '', outputFormat = 'mat', variableFilter = '.*', cflags = '', simflags = ''",
+simulationOptions = "startTime = 0.0, stopTime = 1000.0, numberOfIntervals = 500, tolerance = 1e-6, method = 'dassl', fileNamePrefix = 'ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1', options = '', outputFormat = 'mat', variableFilter = '.*', cflags = '', simflags = ''",
 messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
 LOG_SUCCESS       | info    | The simulation finished successfully.
 "
 end SimulationResult;
 "Warning: Requested package Modelica of version 3.2.3, but this package was already loaded with version 3.2.1. There are no conversion annotations for this version but 3.2.3 is newer than 3.2.1. There is a possibility that 3.2.1 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
@@ -50,11 +50,13 @@
 [ThermoSysPro 3.2.0/WaterSteam/Connectors.mo:3:3-43:17:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidInlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
 [ThermoSysPro 3.2.0/WaterSteam/Connectors.mo:87:3-127:18:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidOutlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
 [ThermoSysPro 3.2.0/ElectroMechanics/Connectors.mo:3:3-36:24:writable] Warning: Connector .ThermoSysPro.ElectroMechanics.Connectors.MechanichalTorque is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0).
 [ThermoSysPro 3.2.0/WaterSteam/Connectors.mo:3:3-43:17:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidInlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
 "
-0
+1
 
-""
-Files equal!
+"Error: Failed to open simulation result ReferenceFiles/ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1.mat: No such file or directory
+Error: Error opening reference file: ReferenceFiles/ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1.mat
+"
+Files not equal!
 
 0
'' 
Equation mismatch: omc-diff says: 
Line 55: Integer 0 != 1

== 1 out of 1 tests failed [simulation/modelica/commonSubExp/ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1.mos_temp7354, time: 25]