Skip to content

Console Output

+ make -C testsuite/special/FmuExportCrossCompile/ test
make: Entering directory '/var/lib/jenkins2/ws/OpenModelica_PR-9565/testsuite/special/FmuExportCrossCompile'
rm -rf *.json *.xml *.html *.fmu* *.c *.makefile *.log *.o *.opt *.libs *.h *.mat *.csv
rm -f BouncingBall FmuExportCrossCompile RoomHeating_OM_RH WaterTank_Control WaterTank_TestSingleWaterTank
rm -rf CMakeCrossCompile/ Test_FMUs/
make fmuExportCrossCompile
make[1]: Entering directory '/var/lib/jenkins2/ws/OpenModelica_PR-9565/testsuite/special/FmuExportCrossCompile'
HOME=/var/lib/jenkins2/ws/OpenModelica_PR-9565/testsuite/special/FmuExportCrossCompile/../../../libraries/ ../../../build/bin/omc fmuExportCrossCompile.mos

"Warning: Requested package Modelica of version 4.0.0, but this package was already loaded with version 3.2.3. There are no conversion annotations for this version but 4.0.0 is newer than 3.2.3. There is a possibility that 3.2.3 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
"

""

""

""

""
{"x86_64-apple-darwin15 docker run docker.openmodelica.org/osxcross-omsimulator:v2.0","arm-linux-gnueabihf docker run docker.openmodelica.org/armcross-omsimulator:v2.0","x86_64-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13","i686-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13-i386","x86_64-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0","i686-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0"}
FmuExportCrossCompile

ba071f20bb43db031f0a772ee1f1f43557f88037070f71080b2e55070936dbe3
d03c06acfb0071a8c5f48774498974968c752ccee30d0f8467aaafb0eb948aec
255baeb1dde34bc748246bd847bd3f176fa7dff4ed2ec1c2876ef1f0a3ad5c4d
9bae363ce1877ecd2bb9b4edee3756900f37efec40a329ddd028147393e63221
596a3d08bdc28a58ed152427e144de1bf63b4816af7fb48cbc6fb6ce717a80a8
20504866ed0149b56eee8f6ee160280dc0d295c32650f419469d757d4c04cef5
1b8d5d82280c522a3ed4f6a97e23e4d33bfa7542631d295930ddcffe0372fc4a
1a01001b1885fce06f182c7ab2d4ae72e5b16e61d5a2e60703508ddfa7fa0e39
39027ca423ed7dc15dd8ced8dd06475bc8d40dead0dc3f7b6adc8e3e3ad7f32d
190190d8510b4051f335bb676f48fdb36348e264631ecd7b6ba470640c32a832
a5fd0697f409f6940014d6b8f424cbbca241ba8e2b1519570502135ab61b41f8
c606c98f38d1ca5000396d5ccbd58f52ccded725dba40a2365367ed2bbf2eb02
Warning: Requested package Complex of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package ModelicaServices of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package Modelica of version 4.0.0, but this package was already loaded with version 3.2.3. There are no conversion annotations for this version but 4.0.0 is newer than 3.2.3. There is a possibility that 3.2.3 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
Notification: The Makefile build for FMUs is deprecated and will be removed in a future version of OpenModelica. Use "--fmuCMakeBuild=true".


record SimulationResult
    resultFile = "/var/lib/jenkins2/ws/OpenModelica_PR-9565/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 0.45, numberOfIntervals = 2000, tolerance = 1e-6, method = 'euler', fileNamePrefix = 'FmuExportCrossCompile', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.0930401019999999,
    timeBackend = 0.0030637710000000003,
    timeSimCode = 9.329210000000001e-4,
    timeTemplates = 0.003592931,
    timeCompile = 0.6878759480000001,
    timeSimulation = 0.019568737000000003,
    timeTotal = 0.80824201
end SimulationResult;
"Warning: Requested package Complex of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package ModelicaServices of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package Modelica of version 4.0.0, but this package was already loaded with version 3.2.3. There are no conversion annotations for this version but 4.0.0 is newer than 3.2.3. There is a possibility that 3.2.3 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
"

true
""
"/var/lib/jenkins2/ws/OpenModelica_PR-9565/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile.fmu"


RoomHeating_OM_RH
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: Requested package Complex of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package ModelicaServices of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package Modelica of version 4.0.0, but this package was already loaded with version 3.2.3. There are no conversion annotations for this version but 4.0.0 is newer than 3.2.3. There is a possibility that 3.2.3 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->Show additional information from the initialization process, in OMNotebook call setCommandLineOptions("-d=initialization").
Notification: The Makefile build for FMUs is deprecated and will be removed in a future version of OpenModelica. Use "--fmuCMakeBuild=true".


record SimulationResult
    resultFile = "/var/lib/jenkins2/ws/OpenModelica_PR-9565/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-6, method = 'euler', fileNamePrefix = 'RoomHeating_OM_RH', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_ASSERT        | warning | [/var/lib/jenkins2/ws/OpenModelica_PR-9565/testsuite/special/FmuExportCrossCompile/RoomHeating_OM.mo:69:5-69:117:writable]
|                 | |       | The following assertion has been violated during initialization at time 0.000000
|                 | |       | ((fanspeed >= 0.01)) --> \"UTRC-FCU-002: FCU air damper should be opened at least 0.10.\"
LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.12356984300000001,
    timeBackend = 0.012361444000000001,
    timeSimCode = 0.002301341,
    timeTemplates = 0.006118902000000001,
    timeCompile = 0.8025722479999999,
    timeSimulation = 0.05778262000000001,
    timeTotal = 1.004821008
end SimulationResult;
"Warning: Requested package Complex of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package ModelicaServices of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package Modelica of version 4.0.0, but this package was already loaded with version 3.2.3. There are no conversion annotations for this version but 4.0.0 is newer than 3.2.3. There is a possibility that 3.2.3 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->Show additional information from the initialization process, in OMNotebook call setCommandLineOptions(\"-d=initialization\").
"

true
""
"/var/lib/jenkins2/ws/OpenModelica_PR-9565/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH.fmu"


WaterTank_Control
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: Requested package Complex of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package ModelicaServices of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package Modelica of version 4.0.0, but this package was already loaded with version 3.2.3. There are no conversion annotations for this version but 4.0.0 is newer than 3.2.3. There is a possibility that 3.2.3 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->Show additional information from the initialization process, in OMNotebook call setCommandLineOptions("-d=initialization").
Notification: The Makefile build for FMUs is deprecated and will be removed in a future version of OpenModelica. Use "--fmuCMakeBuild=true".


record SimulationResult
    resultFile = "/var/lib/jenkins2/ws/OpenModelica_PR-9565/testsuite/special/FmuExportCrossCompile/WaterTank_Control_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-6, method = 'euler', fileNamePrefix = 'WaterTank_Control', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.302998684,
    timeBackend = 0.0017274410000000001,
    timeSimCode = 5.7171e-4,
    timeTemplates = 0.002763591,
    timeCompile = 0.5446182380000001,
    timeSimulation = 0.015581236000000002,
    timeTotal = 0.86838875
end SimulationResult;
"Warning: Requested package Complex of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package ModelicaServices of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package Modelica of version 4.0.0, but this package was already loaded with version 3.2.3. There are no conversion annotations for this version but 4.0.0 is newer than 3.2.3. There is a possibility that 3.2.3 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->Show additional information from the initialization process, in OMNotebook call setCommandLineOptions(\"-d=initialization\").
"

true
""
"/var/lib/jenkins2/ws/OpenModelica_PR-9565/testsuite/special/FmuExportCrossCompile/WaterTank_Control.fmu"


WaterTank_TestSingleWaterTank

44739e46f3f2cfa8f0e8a0ff6f3f66ccf671ea3d85db1f0bb4ef636be5ca1242
9e1d11485676f13c1efd583c7c62b874b0e4bada34d9cad5e3600f6074b0562b
991302c114d243e8146abe4e3cc7d077eb409b17d3e6d5caf55f00fdad21c454
166798ca590e755985d18a2ff6f1b93d905c4c9a545711c4b7efb2bc9ea38f70
8a492cadc4ce301dc2aa0bed410359a3f068df27fdbae893d53e9f1ae1a2038b
8a24efb1ce5321264b9cbcaa194ccef5285a20e00fac7d46d922db99fcda88e1
b0f8a1498fd0b2ee65b698b724da3341ba78defc360a6138450cec90b4b560cf
398f252820399ecca55f72446b6e2c97db836de833536b1c61e9f688a0bad29a
84b1350fa591a2fdb574a25ce798e8a38a701876e5b904d608f622afb9cb22d4
131552d0193a810a4f0626f21c9f242bf0b9d83aa1566de0c7d0240013eaacdb
7e98e2ffc7efa9f2bf0384a6d5a18ed4c22c2272b8f3b5e4d13f290d1c89ec5c
534b05c87d8e61cd0cf89c9f7421c324892ba7605d05c5759d5853e97ceab373
Warning: Requested package Complex of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package ModelicaServices of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package Modelica of version 4.0.0, but this package was already loaded with version 3.2.3. There are no conversion annotations for this version but 4.0.0 is newer than 3.2.3. There is a possibility that 3.2.3 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
[/var/lib/jenkins2/ws/OpenModelica_PR-9565/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation tank.valvecontrol <> 0.0, <> on Real numbers is only allowed inside functions.
[/var/lib/jenkins2/ws/OpenModelica_PR-9565/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation tank.valvecontrol <> 0.0, <> on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->Show additional information from the initialization process, in OMNotebook call setCommandLineOptions("-d=initialization").
Notification: The Makefile build for FMUs is deprecated and will be removed in a future version of OpenModelica. Use "--fmuCMakeBuild=true".


record SimulationResult
    resultFile = "/var/lib/jenkins2/ws/OpenModelica_PR-9565/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-6, method = 'euler', fileNamePrefix = 'WaterTank_TestSingleWaterTank', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.078351557,
    timeBackend = 0.004841301,
    timeSimCode = 0.001135761,
    timeTemplates = 0.004648481,
    timeCompile = 0.586403423,
    timeSimulation = 0.02723916999999998,
    timeTotal = 0.702727083
end SimulationResult;
"Warning: Requested package Complex of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package ModelicaServices of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package Modelica of version 4.0.0, but this package was already loaded with version 3.2.3. There are no conversion annotations for this version but 4.0.0 is newer than 3.2.3. There is a possibility that 3.2.3 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
[/var/lib/jenkins2/ws/OpenModelica_PR-9565/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation tank.valvecontrol <> 0.0, <> on Real numbers is only allowed inside functions.
[/var/lib/jenkins2/ws/OpenModelica_PR-9565/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation tank.valvecontrol <> 0.0, <> on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->Show additional information from the initialization process, in OMNotebook call setCommandLineOptions(\"-d=initialization\").
"

true
""
"/var/lib/jenkins2/ws/OpenModelica_PR-9565/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank.fmu"


BouncingBall
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: Requested package Complex of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package ModelicaServices of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package Modelica of version 4.0.0, but this package was already loaded with version 3.2.3. There are no conversion annotations for this version but 4.0.0 is newer than 3.2.3. There is a possibility that 3.2.3 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
Notification: The Makefile build for FMUs is deprecated and will be removed in a future version of OpenModelica. Use "--fmuCMakeBuild=true".


record SimulationResult
    resultFile = "/var/lib/jenkins2/ws/OpenModelica_PR-9565/testsuite/special/FmuExportCrossCompile/BouncingBall_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-6, method = 'euler', fileNamePrefix = 'BouncingBall', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.268344003,
    timeBackend = 0.003270591,
    timeSimCode = 0.00104494,
    timeTemplates = 0.004110582000000001,
    timeCompile = 0.515488858,
    timeSimulation = 0.029263740000000003,
    timeTotal = 0.8216038440000001
end SimulationResult;
"Warning: Requested package Complex of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package ModelicaServices of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package Modelica of version 4.0.0, but this package was already loaded with version 3.2.3. There are no conversion annotations for this version but 4.0.0 is newer than 3.2.3. There is a possibility that 3.2.3 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
"

true
""
"/var/lib/jenkins2/ws/OpenModelica_PR-9565/testsuite/special/FmuExportCrossCompile/BouncingBall.fmu"



unzip -q FmuExportCrossCompile.fmu -d FmuExportCrossCompile.fmutmp
make check-FmuExportCrossCompile-files
make[2]: Entering directory '/var/lib/jenkins2/ws/OpenModelica_PR-9565/testsuite/special/FmuExportCrossCompile'
FmuExportCrossCompile.fmutmp/binaries/win32/FmuExportCrossCompile.dll: PE32 executable (DLL) (console) Intel 80386, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/win64/FmuExportCrossCompile.dll: PE32+ executable (DLL) (console) x86-64, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/darwin64/FmuExportCrossCompile.dylib: Mach-O 64-bit x86_64 dynamically linked shared library, flags:<NOUNDEFS|DYLDLINK|TWOLEVEL|NO_REEXPORTED_DYLIBS>
FmuExportCrossCompile.fmutmp/binaries/linux32/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, Intel 80386, version 1 (SYSV), dynamically linked, BuildID[sha1]=9aee6242f4f99b4216f221c38e0157a639fa0568, not stripped
FmuExportCrossCompile.fmutmp/binaries/linux64/FmuExportCrossCompile.so: ELF 64-bit LSB shared object, x86-64, version 1 (SYSV), dynamically linked, BuildID[sha1]=59e238e6edc6e0447511c79c0ce93c5fb077a59c, not stripped
FmuExportCrossCompile.fmutmp/binaries/arm-linux-gnueabihf/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, ARM, EABI5 version 1 (SYSV), dynamically linked, BuildID[sha1]=ffe10f59ab7733463b8a9b5a2b8af8fcf795d710, not stripped
make[2]: Leaving directory '/var/lib/jenkins2/ws/OpenModelica_PR-9565/testsuite/special/FmuExportCrossCompile'
make[1]: Leaving directory '/var/lib/jenkins2/ws/OpenModelica_PR-9565/testsuite/special/FmuExportCrossCompile'
make CMakeCrossCompile
make[1]: Entering directory '/var/lib/jenkins2/ws/OpenModelica_PR-9565/testsuite/special/FmuExportCrossCompile'
HOME=/var/lib/jenkins2/ws/OpenModelica_PR-9565/testsuite/special/FmuExportCrossCompile/../../../libraries/ ../../../build/bin/omc CMakeCrossCompile.mos

0
"/var/lib/jenkins2/ws/OpenModelica_PR-9565/testsuite/special/FmuExportCrossCompile/CMakeCrossCompile"

{"x86_64-apple-darwin docker run multiarch/crossbuild","x86_64-linux-gnu docker run multiarch/crossbuild","i686-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13-i386","x86_64-w64-mingw32 docker run multiarch/crossbuild","i686-w64-mingw32 docker run multiarch/crossbuild"}
f72bd04e5b6b783fcde0b319008fa7e1cd43be98b430debe62622e7741b73f75
02508d11b1196f8a8ea1d6ce7bc97a983de9349175d695be080f6d5c743a32f5
d78aa8066cae22a3a7d5c4fa747ac90f8bba82cc14d17340588260cfeb66670d
bc9d2cb554832b1de19db202bcde1623dd7eeea6b48ada154b8b53f46121907c
562ff5f063670466d4360f5262dce68aaf83c7f8960cda8b40ec38b074da8f8c
c1996368bf6fbd3f7ec44b624270f864ace9d56a223e5aead5cd207c59f8a412
ae8594a8af2cd81ed5249c61fd9885e0c441f944b120be33d2cc20df32c456a8
83fc905daf43ecaa141d33958c6c1ec011be77ff8f08478b25430581d28bc893
9a47426396433cf68ca1dfcbcf9f135b4da733ef81675f28016a18a687c7807f
c54928dc2e288a5caa67fc4ee78241dc317a4af64894afd17d5add6881f39b99
"/var/lib/jenkins2/ws/OpenModelica_PR-9565/testsuite/special/FmuExportCrossCompile/CMakeCrossCompile/Modelica.Mechanics.MultiBody.Examples.Elementary.Pendulum.fmu"
""
unzip -qq CMakeCrossCompile/Modelica.Mechanics.MultiBody.Examples.Elementary.Pendulum.fmu -d CMakeCrossCompile/Pendulum_FMU/
make check-CMakeCrossCompile-files
make[2]: Entering directory '/var/lib/jenkins2/ws/OpenModelica_PR-9565/testsuite/special/FmuExportCrossCompile'
CMakeCrossCompile/Pendulum_FMU/binaries/win32/Modelica_Mechanics_MultiBody_Examples_Elementary_Pendulum.dll: PE32 executable (DLL) (console) Intel 80386, for MS Windows
CMakeCrossCompile/Pendulum_FMU/binaries/win64/Modelica_Mechanics_MultiBody_Examples_Elementary_Pendulum.dll: PE32+ executable (DLL) (console) x86-64, for MS Windows
CMakeCrossCompile/Pendulum_FMU/binaries/darwin64/Modelica_Mechanics_MultiBody_Examples_Elementary_Pendulum.dylib: Mach-O 64-bit x86_64 dynamically linked shared library, flags:<NOUNDEFS|DYLDLINK|TWOLEVEL|NO_REEXPORTED_DYLIBS>
CMakeCrossCompile/Pendulum_FMU/binaries/linux32/Modelica_Mechanics_MultiBody_Examples_Elementary_Pendulum.so: ELF 32-bit LSB shared object, Intel 80386, version 1 (SYSV), dynamically linked, BuildID[sha1]=db4bfd54ac4839146b4538b97ff0a6df83f3cce7, with debug_info, not stripped
CMakeCrossCompile/Pendulum_FMU/binaries/linux64/Modelica_Mechanics_MultiBody_Examples_Elementary_Pendulum.so: ELF 64-bit LSB shared object, x86-64, version 1 (SYSV), dynamically linked, BuildID[sha1]=92dc3c7c03a0bac6ba8066d1c9f265401a1a372e, with debug_info, not stripped
make[2]: Leaving directory '/var/lib/jenkins2/ws/OpenModelica_PR-9565/testsuite/special/FmuExportCrossCompile'
make[1]: Leaving directory '/var/lib/jenkins2/ws/OpenModelica_PR-9565/testsuite/special/FmuExportCrossCompile'
make: Leaving directory '/var/lib/jenkins2/ws/OpenModelica_PR-9565/testsuite/special/FmuExportCrossCompile'