Skip to content

Failed

tests / 03 testsuite-gcc 3/3 / simulation_libraries_msl32.Modelica.Fluid.Examples.ControlledTankSystem.ControlledTanks.mos (from (result.xml))

Failing for the past 86 builds (Since #1 )
Took 22 sec.

Stacktrace

Output mismatch (see stdout for details)

Standard Output

 + Modelica.Fluid.Examples.ControlledTankSystem.ControlledTanks                      ... equation mismatch [time: 21]

==== Log /tmp/omc-rtest-unknown/simulation/libraries/msl32/Modelica.Fluid.Examples.ControlledTankSystem.ControlledTanks.mos_temp4392/log-Modelica.Fluid.Examples.ControlledTankSystem.ControlledTanks.mos
"true
"
""
OpenModelicaModelTesting.Kind.VerifiedSimulation
Modelica.Fluid.Examples.ControlledTankSystem.ControlledTanks
{"tank1.level","tank1.medium.T","tank2.level","tank2.medium.T"}
Simulation options: startTime = 0.0, stopTime = 900.0, numberOfIntervals = 500, tolerance = 1e-6, method = 'dassl', fileNamePrefix = 'Modelica.Fluid.Examples.ControlledTankSystem.ControlledTanks', options = '', outputFormat = 'mat', variableFilter = 'time|tank1.level|tank1.medium.T|tank2.level|tank2.medium.T', cflags = '', simflags = ' -abortSlowSimulation -alarm=360 -emit_protected'
Result file: Modelica.Fluid.Examples.ControlledTankSystem.ControlledTanks_res.mat
Messages: LOG_SUCCESS       | info    | The initialization finished successfully with 3 homotopy steps.
LOG_SUCCESS       | info    | The simulation finished successfully.

Files Equal!
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->Show additional information from the initialization process, in OMNotebook call setCommandLineOptions("-d=initialization").
Error: Jacobian A contains non-linear components. This indicates a singular system or internal generation errors.

"true
"
""

Equation mismatch: diff says:
--- /tmp/omc-rtest-unknown/simulation/libraries/msl32/Modelica.Fluid.Examples.ControlledTankSystem.ControlledTanks.mos_temp4392/equations-expected2024-01-20 04:05:38.277818194 +0000
+++ /tmp/omc-rtest-unknown/simulation/libraries/msl32/Modelica.Fluid.Examples.ControlledTankSystem.ControlledTanks.mos_temp4392/equations-got2024-01-20 04:05:59.912773085 +0000
@@ -2,16 +2,17 @@
 "
 ""
 OpenModelicaModelTesting.Kind.VerifiedSimulation
 Modelica.Fluid.Examples.ControlledTankSystem.ControlledTanks
 {"tank1.level","tank1.medium.T","tank2.level","tank2.medium.T"}
-Simulation options: startTime = 0.0, stopTime = 900.0, numberOfIntervals = 500, tolerance = 1e-06, method = 'dassl', fileNamePrefix = 'Modelica.Fluid.Examples.ControlledTankSystem.ControlledTanks', options = '', outputFormat = 'mat', variableFilter = 'time|tank1.level|tank1.medium.T|tank2.level|tank2.medium.T', cflags = '', simflags = ' -abortSlowSimulation -alarm=360 -emit_protected'
+Simulation options: startTime = 0.0, stopTime = 900.0, numberOfIntervals = 500, tolerance = 1e-6, method = 'dassl', fileNamePrefix = 'Modelica.Fluid.Examples.ControlledTankSystem.ControlledTanks', options = '', outputFormat = 'mat', variableFilter = 'time|tank1.level|tank1.medium.T|tank2.level|tank2.medium.T', cflags = '', simflags = ' -abortSlowSimulation -alarm=360 -emit_protected'
 Result file: Modelica.Fluid.Examples.ControlledTankSystem.ControlledTanks_res.mat
 Messages: LOG_SUCCESS       | info    | The initialization finished successfully with 3 homotopy steps.
 LOG_SUCCESS       | info    | The simulation finished successfully.
 
 Files Equal!
 Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->Show additional information from the initialization process, in OMNotebook call setCommandLineOptions("-d=initialization").
+Error: Jacobian A contains non-linear components. This indicates a singular system or internal generation errors.
 
 "true
 "
 ""

Equation mismatch: omc-diff says:
Line 14: Lexical token differs:
expected: 

got:      Error: Jacobian A contains non

== 1 out of 1 tests failed [simulation/libraries/msl32/Modelica.Fluid.Examples.ControlledTankSystem.ControlledTanks.mos_temp4392, time: 22]