Skip to content

Failed

tests / 03 testsuite-gcc 3/3 / simulation_modelica_daemode.testDAEModeFileSplit_Issue4851.mos (from (result.xml))

Failing for the past 11 builds (Since #10 )
Took 6 sec.

Stacktrace

Output mismatch (see stdout for details)

Standard Output

 + testDAEModeFileSplit_Issue4851.mos                                                ... equation mismatch [time: 6]

==== Log /tmp/omc-rtest-omtmpuser/simulation/modelica/daemode/testDAEModeFileSplit_Issue4851.mos_temp8905/log-testDAEModeFileSplit_Issue4851.mos
true
""
true
{"",""}
"Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts.
[BackEnd/Initialization.mo:0:0-0:0:writable] Error: Internal error DAEUtil.getStartAttr failed because type Real has no default start value.
Error: No system for the symbolic initialization was generated
Error: Internal error SimCode DAEmode: The model PowerGrids.Examples.IEEE14bus.IEEE14busGen2Disconnection could not be translated
"
ls: cannot access '*16dae_part*.c': No such file or directory
2
""

Equation mismatch: diff says:
--- /tmp/omc-rtest-omtmpuser/simulation/modelica/daemode/testDAEModeFileSplit_Issue4851.mos_temp8905/equations-expected2024-04-20 01:47:03.064035180 +0000
+++ /tmp/omc-rtest-omtmpuser/simulation/modelica/daemode/testDAEModeFileSplit_Issue4851.mos_temp8905/equations-got2024-04-20 01:47:09.024035464 +0000
@@ -1,12 +1,12 @@
 true
 ""
 true
-{"PowerGrids.Examples.IEEE14bus.IEEE14busGen2Disconnection","PowerGrids.Examples.IEEE14bus.IEEE14busGen2Disconnection_init.xml"}
+{"",""}
 "Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts.
+[BackEnd/Initialization.mo:0:0-0:0:writable] Error: Internal error DAEUtil.getStartAttr failed because type Real has no default start value.
+Error: No system for the symbolic initialization was generated
+Error: Internal error SimCode DAEmode: The model PowerGrids.Examples.IEEE14bus.IEEE14busGen2Disconnection could not be translated
 "
-PowerGrids.Examples.IEEE14bus.IEEE14busGen2Disconnection_16dae_part0.c
-PowerGrids.Examples.IEEE14bus.IEEE14busGen2Disconnection_16dae_part1.c
-PowerGrids.Examples.IEEE14bus.IEEE14busGen2Disconnection_16dae_part2.c
-PowerGrids.Examples.IEEE14bus.IEEE14busGen2Disconnection_16dae_part3.c
-0
+ls: cannot access '*16dae_part*.c': No such file or directory
+2
 ""

Equation mismatch: omc-diff says:
Failed 'P' '"'
Line 4: Text differs:
expected: {"PowerGrids.Examples.IEEE
got:      {"",""}

== 1 out of 1 tests failed [simulation/modelica/daemode/testDAEModeFileSplit_Issue4851.mos_temp8905, time: 6]