Skip to content

Failed

tests / 03 testsuite-gcc 3/3 / simulation_modelica_synchronous.TestClockParameterEvaluation.mos (from (result.xml))

Failing for the past 11 builds (Since #10 )
Took 7 sec.

Stacktrace

Output mismatch (see stdout for details)

Standard Output

 + TestClockParameterEvaluation.mos                                                  ... equation mismatch [time: 7]

==== Log /tmp/omc-rtest-omtmpuser/simulation/modelica/synchronous/TestClockParameterEvaluation.mos_temp5690/log-TestClockParameterEvaluation.mos
true
""
true
""
true
"Warning: Requested package Modelica of version 3.2.3, but this package was already loaded with version 3.2.2. There are no conversion annotations for this version but 3.2.3 is newer than 3.2.2. There is a possibility that 3.2.2 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
Warning: Requested package ModelicaServices of version 3.2.3, but this package was already loaded with version 3.2.2. There are no conversion annotations for this version but 3.2.3 is newer than 3.2.2. There is a possibility that 3.2.2 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
"
record SimulationResult
    resultFile = "",
    simulationOptions = "startTime = 0.0, stopTime = 300.0, numberOfIntervals = 500, tolerance = 1e-6, method = 'dassl', fileNamePrefix = 'Modelica_Synchronous.Examples.Systems.ControlledMixingUnit', options = '', outputFormat = 'mat', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "Failed to build model: Modelica_Synchronous.Examples.Systems.ControlledMixingUnit"
end SimulationResult;
"Warning: Requested package Modelica of version 3.2.3, but this package was already loaded with version 3.2.2. There are no conversion annotations for this version but 3.2.3 is newer than 3.2.2. There is a possibility that 3.2.2 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
Warning: Requested package ModelicaServices of version 3.2.3, but this package was already loaded with version 3.2.2. There are no conversion annotations for this version but 3.2.3 is newer than 3.2.2. There is a possibility that 3.2.2 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
[BackEnd/Initialization.mo:0:0-0:0:writable] Error: Internal error DAEUtil.getStartAttr failed because type Real has no default start value.
Error: No system for the symbolic initialization was generated
"
record SimulationResult
    resultFile = "",
    simulationOptions = "startTime = 0.0, stopTime = 5.0, numberOfIntervals = 500, tolerance = 1e-6, method = 'dassl', fileNamePrefix = 'Modelica_Synchronous.Examples.SimpleControlledDrive.ClockedWithDiscretizedContinuousController', options = '', outputFormat = 'mat', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "Failed to build model: Modelica_Synchronous.Examples.SimpleControlledDrive.ClockedWithDiscretizedContinuousController"
end SimulationResult;
"Warning: Requested package Modelica of version 3.2.3, but this package was already loaded with version 3.2.2. There are no conversion annotations for this version but 3.2.3 is newer than 3.2.2. There is a possibility that 3.2.2 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
Warning: Requested package ModelicaServices of version 3.2.3, but this package was already loaded with version 3.2.2. There are no conversion annotations for this version but 3.2.3 is newer than 3.2.2. There is a possibility that 3.2.2 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
[BackEnd/Initialization.mo:0:0-0:0:writable] Error: Internal error DAEUtil.getStartAttr failed because type Real has no default start value.
Error: No system for the symbolic initialization was generated
"

Equation mismatch: diff says:
--- /tmp/omc-rtest-omtmpuser/simulation/modelica/synchronous/TestClockParameterEvaluation.mos_temp5690/equations-expected2024-04-20 01:51:04.512046095 +0000
+++ /tmp/omc-rtest-omtmpuser/simulation/modelica/synchronous/TestClockParameterEvaluation.mos_temp5690/equations-got2024-04-20 01:51:11.824046410 +0000
@@ -5,26 +5,24 @@
 true
 "Warning: Requested package Modelica of version 3.2.3, but this package was already loaded with version 3.2.2. There are no conversion annotations for this version but 3.2.3 is newer than 3.2.2. There is a possibility that 3.2.2 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
 Warning: Requested package ModelicaServices of version 3.2.3, but this package was already loaded with version 3.2.2. There are no conversion annotations for this version but 3.2.3 is newer than 3.2.2. There is a possibility that 3.2.2 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
 "
 record SimulationResult
-resultFile = "Modelica_Synchronous.Examples.Systems.ControlledMixingUnit_res.mat",
-simulationOptions = "startTime = 0.0, stopTime = 300.0, numberOfIntervals = 500, tolerance = 1e-06, method = 'dassl', fileNamePrefix = 'Modelica_Synchronous.Examples.Systems.ControlledMixingUnit', options = '', outputFormat = 'mat', variableFilter = '.*', cflags = '', simflags = ''",
-messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
-LOG_SUCCESS       | info    | The simulation finished successfully.
-"
+resultFile = "",
+simulationOptions = "startTime = 0.0, stopTime = 300.0, numberOfIntervals = 500, tolerance = 1e-6, method = 'dassl', fileNamePrefix = 'Modelica_Synchronous.Examples.Systems.ControlledMixingUnit', options = '', outputFormat = 'mat', variableFilter = '.*', cflags = '', simflags = ''",
+messages = "Failed to build model: Modelica_Synchronous.Examples.Systems.ControlledMixingUnit"
 end SimulationResult;
 "Warning: Requested package Modelica of version 3.2.3, but this package was already loaded with version 3.2.2. There are no conversion annotations for this version but 3.2.3 is newer than 3.2.2. There is a possibility that 3.2.2 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
 Warning: Requested package ModelicaServices of version 3.2.3, but this package was already loaded with version 3.2.2. There are no conversion annotations for this version but 3.2.3 is newer than 3.2.2. There is a possibility that 3.2.2 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
+[BackEnd/Initialization.mo:0:0-0:0:writable] Error: Internal error DAEUtil.getStartAttr failed because type Real has no default start value.
+Error: No system for the symbolic initialization was generated
 "
 record SimulationResult
-resultFile = "Modelica_Synchronous.Examples.SimpleControlledDrive.ClockedWithDiscretizedContinuousController_res.mat",
-simulationOptions = "startTime = 0.0, stopTime = 5.0, numberOfIntervals = 500, tolerance = 1e-06, method = 'dassl', fileNamePrefix = 'Modelica_Synchronous.Examples.SimpleControlledDrive.ClockedWithDiscretizedContinuousController', options = '', outputFormat = 'mat', variableFilter = '.*', cflags = '', simflags = ''",
-messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
-LOG_SUCCESS       | info    | The simulation finished successfully.
-"
+resultFile = "",
+simulationOptions = "startTime = 0.0, stopTime = 5.0, numberOfIntervals = 500, tolerance = 1e-6, method = 'dassl', fileNamePrefix = 'Modelica_Synchronous.Examples.SimpleControlledDrive.ClockedWithDiscretizedContinuousController', options = '', outputFormat = 'mat', variableFilter = '.*', cflags = '', simflags = ''",
+messages = "Failed to build model: Modelica_Synchronous.Examples.SimpleControlledDrive.ClockedWithDiscretizedContinuousController"
 end SimulationResult;
 "Warning: Requested package Modelica of version 3.2.3, but this package was already loaded with version 3.2.2. There are no conversion annotations for this version but 3.2.3 is newer than 3.2.2. There is a possibility that 3.2.2 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
 Warning: Requested package ModelicaServices of version 3.2.3, but this package was already loaded with version 3.2.2. There are no conversion annotations for this version but 3.2.3 is newer than 3.2.2. There is a possibility that 3.2.2 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
-Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: PI.y = PI.y_start (0.0 = PI.y_start)
-Warning: The initial conditions are over specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->Show additional information from the initialization process, in OMNotebook call setCommandLineOptions(\"-d=initialization\").
+[BackEnd/Initialization.mo:0:0-0:0:writable] Error: Internal error DAEUtil.getStartAttr failed because type Real has no default start value.
+Error: No system for the symbolic initialization was generated
 "

Equation mismatch: omc-diff says:
Failed 'M' '"'
Line 10: Text differs:
expected: resultFile = "Modelica_Synchronous.Examples.Systems.ControlledMixingUnit_res.mat",
got:      resultFile = "",

== 1 out of 1 tests failed [simulation/modelica/synchronous/TestClockParameterEvaluation.mos_temp5690, time: 7]