Skip to content

Console Output

+ make -C testsuite/special/FmuExportCrossCompile/ test
make: Entering directory '/var/lib/jenkins1/ws/OpenModelica_PR-11632/testsuite/special/FmuExportCrossCompile'
rm -rf *.json *.xml *.html *.fmu* *.c *.makefile *.log *.o *.opt *.libs *.h *.mat *.csv
rm -f BouncingBall FmuExportCrossCompile RoomHeating_OM_RH WaterTank_Control WaterTank_TestSingleWaterTank
rm -rf CMakeCrossCompile/ Test_FMUs/
make fmuExportCrossCompile
make[1]: Entering directory '/var/lib/jenkins1/ws/OpenModelica_PR-11632/testsuite/special/FmuExportCrossCompile'
HOME=/var/lib/jenkins1/ws/OpenModelica_PR-11632/testsuite/special/FmuExportCrossCompile/../../../libraries/ ../../../build/bin/omc fmuExportCrossCompile.mos

"Warning: Requested package Modelica of version 4.0.0, but this package was already loaded with version 3.2.3. There are no conversion annotations for this version but 4.0.0 is newer than 3.2.3. There is a possibility that 3.2.3 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
"

""

""

""

""
{"x86_64-apple-darwin15 docker run docker.openmodelica.org/osxcross-omsimulator:v2.0","arm-linux-gnueabihf docker run docker.openmodelica.org/armcross-omsimulator:v2.0","x86_64-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13","i686-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13-i386","x86_64-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0","i686-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0"}
FmuExportCrossCompile
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: Requested package Complex of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package ModelicaServices of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package Modelica of version 4.0.0, but this package was already loaded with version 3.2.3. There are no conversion annotations for this version but 4.0.0 is newer than 3.2.3. There is a possibility that 3.2.3 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
Notification: The Makefile build for FMUs is deprecated and will be removed in a future version of OpenModelica. Use "--fmuCMakeBuild=true".


record SimulationResult
    resultFile = "/var/lib/jenkins1/ws/OpenModelica_PR-11632/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 0.45, numberOfIntervals = 2000, tolerance = 1e-6, method = 'euler', fileNamePrefix = 'FmuExportCrossCompile', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.10498774200000001,
    timeBackend = 0.004831969,
    timeSimCode = 0.001441868,
    timeTemplates = 0.08153141200000001,
    timeCompile = 0.558665329,
    timeSimulation = 0.0236242,
    timeTotal = 0.775248199
end SimulationResult;
"Warning: Requested package Complex of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package ModelicaServices of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package Modelica of version 4.0.0, but this package was already loaded with version 3.2.3. There are no conversion annotations for this version but 4.0.0 is newer than 3.2.3. There is a possibility that 3.2.3 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
"

true
""
"/var/lib/jenkins1/ws/OpenModelica_PR-11632/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile.fmu"


RoomHeating_OM_RH

88ac55238bb2d74a7b1384f496e4eec67e50e4bae16f9e21ffce372459c3b6bd
db3dca611631850861275f285bdacf6334b5cade748cbe816932a87d1073fe9d
2d8ac5935eafd131fa80bfe03f960fe93a70b8b2f595fe359f6d9eeb2a4377e7
baf2d9a81dad3fb40db0de5e436684d0055e4c386ee6f8ad19243ab5e0276e5c
30363fd43e95beca35e8e63126bb6296171b47cc85d29ee4c7dae7c3cc46c50e
6ae08b097e808aea25c5ffc9b91b04ae1e36dafbb5aa5b8afcfae844744a58a7
f5f5194403637927e3100fbffab031341719680319653de61b5fb5b2bc3a4f6b
589b82e7684a7b413b80e29dbce7fc94ba48f4bbe7763b6259a6bf18c89a5155
c7314ee1da4d1a65f1b418b75daee4c40eb16094ae3bd176dc773aa7169c4384
cfc75c95d5f8a4eb1c2bcfff93491daaafde840406e0bd781f44105ede4dfa46
dc1f45654b3d0115167e575dc052449d3d4d931b0ed707ae6c363247bd338bf3
dadf42ad4503ea3012df7761d911106e837d2cc5b4ec4af38372b358544435c5
Warning: Requested package Complex of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package ModelicaServices of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package Modelica of version 4.0.0, but this package was already loaded with version 3.2.3. There are no conversion annotations for this version but 4.0.0 is newer than 3.2.3. There is a possibility that 3.2.3 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->Show additional information from the initialization process, in OMNotebook call setCommandLineOptions("-d=initialization").
Notification: The Makefile build for FMUs is deprecated and will be removed in a future version of OpenModelica. Use "--fmuCMakeBuild=true".


record SimulationResult
    resultFile = "/var/lib/jenkins1/ws/OpenModelica_PR-11632/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-6, method = 'euler', fileNamePrefix = 'RoomHeating_OM_RH', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_ASSERT        | warning | [/var/lib/jenkins1/ws/OpenModelica_PR-11632/testsuite/special/FmuExportCrossCompile/RoomHeating_OM.mo:69:5-69:117:writable]
|                 | |       | The following assertion has been violated during initialization at time 0.000000
|                 | |       | ((fanspeed >= 0.01)) --> \"UTRC-FCU-002: FCU air damper should be opened at least 0.10.\"
LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.389677505,
    timeBackend = 0.018152688,
    timeSimCode = 0.0027028350000000002,
    timeTemplates = 0.005136037,
    timeCompile = 0.687085944,
    timeSimulation = 0.05924877899999992,
    timeTotal = 1.162104337
end SimulationResult;
"Warning: Requested package Complex of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package ModelicaServices of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package Modelica of version 4.0.0, but this package was already loaded with version 3.2.3. There are no conversion annotations for this version but 4.0.0 is newer than 3.2.3. There is a possibility that 3.2.3 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->Show additional information from the initialization process, in OMNotebook call setCommandLineOptions(\"-d=initialization\").
"

true
""
"/var/lib/jenkins1/ws/OpenModelica_PR-11632/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH.fmu"


WaterTank_Control
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: Requested package Complex of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package ModelicaServices of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package Modelica of version 4.0.0, but this package was already loaded with version 3.2.3. There are no conversion annotations for this version but 4.0.0 is newer than 3.2.3. There is a possibility that 3.2.3 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->Show additional information from the initialization process, in OMNotebook call setCommandLineOptions("-d=initialization").
Notification: The Makefile build for FMUs is deprecated and will be removed in a future version of OpenModelica. Use "--fmuCMakeBuild=true".


record SimulationResult
    resultFile = "/var/lib/jenkins1/ws/OpenModelica_PR-11632/testsuite/special/FmuExportCrossCompile/WaterTank_Control_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-6, method = 'euler', fileNamePrefix = 'WaterTank_Control', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.11495986300000001,
    timeBackend = 0.0026182030000000004,
    timeSimCode = 8.268230000000001e-4,
    timeTemplates = 0.3591499859999999,
    timeCompile = 0.553356662,
    timeSimulation = 0.018266843,
    timeTotal = 1.04929016
end SimulationResult;
"Warning: Requested package Complex of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package ModelicaServices of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package Modelica of version 4.0.0, but this package was already loaded with version 3.2.3. There are no conversion annotations for this version but 4.0.0 is newer than 3.2.3. There is a possibility that 3.2.3 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->Show additional information from the initialization process, in OMNotebook call setCommandLineOptions(\"-d=initialization\").
"

true
""
"/var/lib/jenkins1/ws/OpenModelica_PR-11632/testsuite/special/FmuExportCrossCompile/WaterTank_Control.fmu"


WaterTank_TestSingleWaterTank
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: Requested package Complex of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package ModelicaServices of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package Modelica of version 4.0.0, but this package was already loaded with version 3.2.3. There are no conversion annotations for this version but 4.0.0 is newer than 3.2.3. There is a possibility that 3.2.3 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
[/var/lib/jenkins1/ws/OpenModelica_PR-11632/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation tank.valvecontrol <> 0.0, <> on Real numbers is only allowed inside functions.
[/var/lib/jenkins1/ws/OpenModelica_PR-11632/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation tank.valvecontrol <> 0.0, <> on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->Show additional information from the initialization process, in OMNotebook call setCommandLineOptions("-d=initialization").
Notification: The Makefile build for FMUs is deprecated and will be removed in a future version of OpenModelica. Use "--fmuCMakeBuild=true".


record SimulationResult
    resultFile = "/var/lib/jenkins1/ws/OpenModelica_PR-11632/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-6, method = 'euler', fileNamePrefix = 'WaterTank_TestSingleWaterTank', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.092289253,
    timeBackend = 0.008937021,
    timeSimCode = 0.0019643340000000003,
    timeTemplates = 0.004866365,
    timeCompile = 0.58747787,
    timeSimulation = 0.037663577000000004,
    timeTotal = 0.733300206
end SimulationResult;
"Warning: Requested package Complex of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package ModelicaServices of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package Modelica of version 4.0.0, but this package was already loaded with version 3.2.3. There are no conversion annotations for this version but 4.0.0 is newer than 3.2.3. There is a possibility that 3.2.3 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
[/var/lib/jenkins1/ws/OpenModelica_PR-11632/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation tank.valvecontrol <> 0.0, <> on Real numbers is only allowed inside functions.
[/var/lib/jenkins1/ws/OpenModelica_PR-11632/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation tank.valvecontrol <> 0.0, <> on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->Show additional information from the initialization process, in OMNotebook call setCommandLineOptions(\"-d=initialization\").
"

true
""
"/var/lib/jenkins1/ws/OpenModelica_PR-11632/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank.fmu"


BouncingBall
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: Requested package Complex of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package ModelicaServices of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package Modelica of version 4.0.0, but this package was already loaded with version 3.2.3. There are no conversion annotations for this version but 4.0.0 is newer than 3.2.3. There is a possibility that 3.2.3 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
Notification: The Makefile build for FMUs is deprecated and will be removed in a future version of OpenModelica. Use "--fmuCMakeBuild=true".


record SimulationResult
    resultFile = "/var/lib/jenkins1/ws/OpenModelica_PR-11632/testsuite/special/FmuExportCrossCompile/BouncingBall_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-6, method = 'euler', fileNamePrefix = 'BouncingBall', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.111697716,
    timeBackend = 0.005253351000000001,
    timeSimCode = 0.001585793,
    timeTemplates = 0.003195551,
    timeCompile = 0.666487242,
    timeSimulation = 0.023594740000000003,
    timeTotal = 0.811957633
end SimulationResult;
"Warning: Requested package Complex of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package ModelicaServices of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package Modelica of version 4.0.0, but this package was already loaded with version 3.2.3. There are no conversion annotations for this version but 4.0.0 is newer than 3.2.3. There is a possibility that 3.2.3 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
"

true
""
"/var/lib/jenkins1/ws/OpenModelica_PR-11632/testsuite/special/FmuExportCrossCompile/BouncingBall.fmu"



unzip -q FmuExportCrossCompile.fmu -d FmuExportCrossCompile.fmutmp
make check-FmuExportCrossCompile-files
make[2]: Entering directory '/var/lib/jenkins1/ws/OpenModelica_PR-11632/testsuite/special/FmuExportCrossCompile'
FmuExportCrossCompile.fmutmp/binaries/win32/FmuExportCrossCompile.dll: PE32 executable (DLL) (console) Intel 80386, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/win64/FmuExportCrossCompile.dll: PE32+ executable (DLL) (console) x86-64, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/darwin64/FmuExportCrossCompile.dylib: Mach-O 64-bit x86_64 dynamically linked shared library, flags:<NOUNDEFS|DYLDLINK|TWOLEVEL|NO_REEXPORTED_DYLIBS>
FmuExportCrossCompile.fmutmp/binaries/linux32/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, Intel 80386, version 1 (SYSV), dynamically linked, BuildID[sha1]=fd01d30c87312e6ea12702a6d2527a7f98bfbdde, not stripped
FmuExportCrossCompile.fmutmp/binaries/linux64/FmuExportCrossCompile.so: ELF 64-bit LSB shared object, x86-64, version 1 (SYSV), dynamically linked, BuildID[sha1]=0dd39d431dea0242a439ddf2e61bb3eb7bae7c71, not stripped
FmuExportCrossCompile.fmutmp/binaries/arm-linux-gnueabihf/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, ARM, EABI5 version 1 (SYSV), dynamically linked, BuildID[sha1]=31a2d38df3e6e45f0e438002b3a86180c72a6148, not stripped
make[2]: Leaving directory '/var/lib/jenkins1/ws/OpenModelica_PR-11632/testsuite/special/FmuExportCrossCompile'
make[1]: Leaving directory '/var/lib/jenkins1/ws/OpenModelica_PR-11632/testsuite/special/FmuExportCrossCompile'
make CMakeCrossCompile
make[1]: Entering directory '/var/lib/jenkins1/ws/OpenModelica_PR-11632/testsuite/special/FmuExportCrossCompile'
HOME=/var/lib/jenkins1/ws/OpenModelica_PR-11632/testsuite/special/FmuExportCrossCompile/../../../libraries/ ../../../build/bin/omc CMakeCrossCompile.mos

0
"/var/lib/jenkins1/ws/OpenModelica_PR-11632/testsuite/special/FmuExportCrossCompile/CMakeCrossCompile"

{"x86_64-apple-darwin docker run multiarch/crossbuild","x86_64-linux-gnu docker run multiarch/crossbuild","i686-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13-i386","x86_64-w64-mingw32 docker run multiarch/crossbuild","i686-w64-mingw32 docker run multiarch/crossbuild"}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"/var/lib/jenkins1/ws/OpenModelica_PR-11632/testsuite/special/FmuExportCrossCompile/CMakeCrossCompile/Modelica.Mechanics.MultiBody.Examples.Elementary.Pendulum.fmu"
""
unzip -qq CMakeCrossCompile/Modelica.Mechanics.MultiBody.Examples.Elementary.Pendulum.fmu -d CMakeCrossCompile/Pendulum_FMU/
make check-CMakeCrossCompile-files
make[2]: Entering directory '/var/lib/jenkins1/ws/OpenModelica_PR-11632/testsuite/special/FmuExportCrossCompile'
CMakeCrossCompile/Pendulum_FMU/binaries/win32/Modelica_Mechanics_MultiBody_Examples_Elementary_Pendulum.dll: PE32 executable (DLL) (console) Intel 80386, for MS Windows
CMakeCrossCompile/Pendulum_FMU/binaries/win64/Modelica_Mechanics_MultiBody_Examples_Elementary_Pendulum.dll: PE32+ executable (DLL) (console) x86-64, for MS Windows
CMakeCrossCompile/Pendulum_FMU/binaries/darwin64/Modelica_Mechanics_MultiBody_Examples_Elementary_Pendulum.dylib: Mach-O 64-bit x86_64 dynamically linked shared library, flags:<NOUNDEFS|DYLDLINK|TWOLEVEL|NO_REEXPORTED_DYLIBS>
CMakeCrossCompile/Pendulum_FMU/binaries/linux32/Modelica_Mechanics_MultiBody_Examples_Elementary_Pendulum.so: ELF 32-bit LSB shared object, Intel 80386, version 1 (SYSV), dynamically linked, BuildID[sha1]=9be0dc942af3084b32301fd68f6a9cb2d405243a, with debug_info, not stripped
CMakeCrossCompile/Pendulum_FMU/binaries/linux64/Modelica_Mechanics_MultiBody_Examples_Elementary_Pendulum.so: ELF 64-bit LSB shared object, x86-64, version 1 (SYSV), dynamically linked, BuildID[sha1]=7026c42c4e9367b5d9e9e5fd6cd08ccd33268f56, with debug_info, not stripped
make[2]: Leaving directory '/var/lib/jenkins1/ws/OpenModelica_PR-11632/testsuite/special/FmuExportCrossCompile'
make[1]: Leaving directory '/var/lib/jenkins1/ws/OpenModelica_PR-11632/testsuite/special/FmuExportCrossCompile'
make: Leaving directory '/var/lib/jenkins1/ws/OpenModelica_PR-11632/testsuite/special/FmuExportCrossCompile'