Skip to content

Failed

tests / 04 testsuite-clang 1/3 / simulation_libraries_msl32.Modelica.Fluid.Examples.Explanatory.MomentumBalanceFittings.mos (from (result.xml))

Failing for the past 11 builds (Since #2 )
Took 10 sec.

Stacktrace

Output mismatch (see stdout for details)

Standard Output

 + Modelica.Fluid.Examples.Explanatory.MomentumBalanceFittings                       ... execution failed

==== Log /tmp/omc-rtest-unknown/simulation/libraries/msl32/Modelica.Fluid.Examples.Explanatory.MomentumBalanceFittings.mos_temp7529/log-Modelica.Fluid.Examples.Explanatory.MomentumBalanceFittings.mos
"true
"
""
OpenModelicaModelTesting.Kind.SimpleSimulation
Modelica.Fluid.Examples.Explanatory.MomentumBalanceFittings
{"leftBoundary1.ports[1].m_flow","leftBoundary1.ports[1].p","leftBoundary1.ports[1].h_outflow","rightBoundary1.ports[1].m_flow","rightBoundary1.ports[1].p","rightBoundary1.ports[1].h_outflow","leftBoundary2.ports[1].m_flow","leftBoundary2.ports[1].p","leftBoundary2.ports[1].h_outflow","rightBoundary2.ports[1].m_flow","rightBoundary2.ports[1].p","rightBoundary2.ports[1].h_outflow"}
Simulation options: startTime = 0.0, stopTime = 1.1, numberOfIntervals = 500, tolerance = 1e-6, method = 'dassl', fileNamePrefix = 'Modelica.Fluid.Examples.Explanatory.MomentumBalanceFittings', options = '', outputFormat = 'mat', variableFilter = 'time|leftBoundary1.ports.1..m_flow|leftBoundary1.ports.1..p|leftBoundary1.ports.1..h_outflow|rightBoundary1.ports.1..m_flow|rightBoundary1.ports.1..p|rightBoundary1.ports.1..h_outflow|leftBoundary2.ports.1..m_flow|leftBoundary2.ports.1..p|leftBoundary2.ports.1..h_outflow|rightBoundary2.ports.1..m_flow|rightBoundary2.ports.1..p|rightBoundary2.ports.1..h_outflow', cflags = '', simflags = ' -abortSlowSimulation -alarm=360 -emit_protected'
Error: Simulation did not produce a result-file
Errors: Failed to build model: Modelica.Fluid.Examples.Explanatory.MomentumBalanceFittings[Modelica 3.2.1+maint.om/Fluid/Interfaces.mo:734:9-739:39:writable] Notification: From here:
[Modelica 3.2.1+maint.om/Fluid/Interfaces.mo:327:3-329:69:writable] Warning: Inherited elements are not identical: bug: https://trac.modelica.org/Modelica/ticket/627
first:  Medium.MassFlowRate m_flow(min = if allowFlowReversal then -Modelica.Constants.inf else 0, start = m_flow_start, stateSelect = if momentumDynamics == Modelica.Fluid.Types.Dynamics.SteadyState then StateSelect.default else StateSelect.prefer) "mass flow rates between states"
second: Medium.MassFlowRate m_flow(min = if allowFlowReversal then -Modelica.Constants.inf else 0, start = m_flow_start) "Mass flow rate in design flow direction"
Continue ....
[Modelica 3.2.1+maint.om/Fluid/Interfaces.mo:734:9-739:39:writable] Notification: From here:
[Modelica 3.2.1+maint.om/Fluid/Interfaces.mo:327:3-329:69:writable] Warning: Inherited elements are not identical: bug: https://trac.modelica.org/Modelica/ticket/627
first:  Medium.MassFlowRate m_flow(min = if allowFlowReversal then -Modelica.Constants.inf else 0, start = m_flow_start, stateSelect = if momentumDynamics == Modelica.Fluid.Types.Dynamics.SteadyState then StateSelect.default else StateSelect.prefer) "mass flow rates between states"
second: Medium.MassFlowRate m_flow(min = if allowFlowReversal then -Modelica.Constants.inf else 0, start = m_flow_start) "Mass flow rate in design flow direction"
Continue ....
[Modelica 3.2.1+maint.om/Fluid/Interfaces.mo:734:9-739:39:writable] Notification: From here:
[Modelica 3.2.1+maint.om/Fluid/Interfaces.mo:327:3-329:69:writable] Warning: Inherited elements are not identical: bug: https://trac.modelica.org/Modelica/ticket/627
first:  Medium.MassFlowRate m_flow(min = if allowFlowReversal then -Modelica.Constants.inf else 0, start = m_flow_start, stateSelect = if momentumDynamics == Modelica.Fluid.Types.Dynamics.SteadyState then StateSelect.default else StateSelect.prefer) "mass flow rates between states"
second: Medium.MassFlowRate m_flow(min = if allowFlowReversal then -Modelica.Constants.inf else 0, start = m_flow_start) "Mass flow rate in design flow direction"
Continue ....
[Modelica 3.2.1+maint.om/Fluid/Interfaces.mo:734:9-739:39:writable] Notification: From here:
[Modelica 3.2.1+maint.om/Fluid/Interfaces.mo:327:3-329:69:writable] Warning: Inherited elements are not identical: bug: https://trac.modelica.org/Modelica/ticket/627
first:  Medium.MassFlowRate m_flow(min = if allowFlowReversal then -Modelica.Constants.inf else 0, start = m_flow_start, stateSelect = if momentumDynamics == Modelica.Fluid.Types.Dynamics.SteadyState then StateSelect.default else StateSelect.prefer) "mass flow rates between states"
second: Medium.MassFlowRate m_flow(min = if allowFlowReversal then -Modelica.Constants.inf else 0, start = m_flow_start) "Mass flow rate in design flow direction"
Continue ....
Error: Template error: A template call failed (/var/lib/jenkins2/ws/OpenModelica_PR-11485/build/bin/../lib/x86_64-linux-gnu/omc/libOpenModelicaCompiler.so: (null)). One possible reason could be that a template imported function call failed (which should not happen for functions called from within template code; templates assert pure 'match'/non-failing semantics).
[SimCode/SimCodeMain.mo:0:0-0:0:writable] Error: Internal error /var/lib/jenkins2/ws/OpenModelica_PR-11485/build/bin/../lib/x86_64-linux-gnu/omc/libOpenModelicaCompiler.so: (null) failed
Error: Template error: A template call failed (/var/lib/jenkins2/ws/OpenModelica_PR-11485/build/bin/../lib/x86_64-linux-gnu/omc/libOpenModelicaCompiler.so: (null)). One possible reason could be that a template imported function call failed (which should not happen for functions called from within template code; templates assert pure 'match'/non-failing semantics).
[SimCode/SimCodeMain.mo:0:0-0:0:writable] Error: Internal error /var/lib/jenkins2/ws/OpenModelica_PR-11485/build/bin/../lib/x86_64-linux-gnu/omc/libOpenModelicaCompiler.so: (null) failed


== 1 out of 1 tests failed [simulation/libraries/msl32/Modelica.Fluid.Examples.Explanatory.MomentumBalanceFittings.mos_temp7529, time: 10]