Skip to content

Failed

tests / 04 testsuite-clang 1/3 / simulation_libraries_3rdParty_ThermoSysPro.ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum.mos (from (result.xml))

Failing for the past 46 builds (Since #8 )
Took 1 min 3 sec.

Stacktrace

Output mismatch (see stdout for details)

Standard Output

 + ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum.mos [simulation checking]    ... equation mismatch [time: 63]

==== Log /tmp/omc-rtest-omtmpuser/simulation/libraries/3rdParty/ThermoSysPro/ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum.mos_temp3497/log-ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum.mos
true
""
true
""
record SimulationResult
    resultFile = "ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum_res.mat",
    simulationOptions = "startTime = 0.0, stopTime = 1000.0, numberOfIntervals = 500, tolerance = 1e-6, method = 'dassl', fileNamePrefix = 'ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum', options = '', outputFormat = 'mat', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
"
end SimulationResult;
"[ThermoSysPro 3.2.0/WaterSteam/Connectors.mo:3:3-43:17:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidInlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
[ThermoSysPro 3.2.0/WaterSteam/Connectors.mo:87:3-127:18:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidOutlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
[ThermoSysPro 3.2.0/WaterSteam/Connectors.mo:3:3-43:17:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidInlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
[ThermoSysPro 3.2.0/WaterSteam/Connectors.mo:87:3-127:18:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidOutlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
[ThermoSysPro 3.2.0/Properties/WaterSteam/Common.mo:1494:3-1528:30:writable] Warning: sat.T was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/Properties/WaterSteam/Common.mo:1494:3-1528:30:writable] Warning: sat.dpT was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/Properties/WaterSteam/Common.mo:1552:3-1581:34:writable] Warning: sat.T was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/Properties/WaterSteam/Common.mo:1552:3-1581:34:writable] Warning: sat.dpT was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/Properties/WaterSteam/Common.mo:1552:3-1581:34:writable] Warning: sat.cpt was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/Properties/WaterSteam/Common.mo:1552:3-1581:34:writable] Warning: sat.vt was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/Properties/WaterSteam/Common.mo:1552:3-1581:34:writable] Warning: sat.vp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/Properties/WaterSteam/Common.mo:1552:3-1581:34:writable] Warning: sat.vtt was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/Properties/WaterSteam/Common.mo:1552:3-1581:34:writable] Warning: sat.vpp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/Properties/WaterSteam/Common.mo:1552:3-1581:34:writable] Warning: sat.vtp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/Properties/WaterSteam/IF97_packages.mo:1089:9-1089:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/Properties/WaterSteam/IF97_packages.mo:851:9-851:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/Properties/WaterSteam/IF97_packages.mo:784:9-784:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/Properties/WaterSteam/Common.mo:162:3-214:22:writable] Warning: pro.x was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/Properties/WaterSteam/Common.mo:252:3-295:26:writable] Warning: pro.duph was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/Properties/WaterSteam/Common.mo:252:3-295:26:writable] Warning: pro.duhp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/Properties/WaterSteam/Common.mo:252:3-295:26:writable] Warning: pro.x was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/Properties/WaterSteam/Common.mo:1270:3-1340:18:writable] Warning: pro.duph was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/Properties/WaterSteam/Common.mo:1270:3-1340:18:writable] Warning: pro.duhp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/Properties/WaterSteam/Common.mo:646:3-701:20:writable] Warning: sat.pt was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/Properties/WaterSteam/Common.mo:646:3-701:20:writable] Warning: sat.cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/WaterSteam/Connectors.mo:3:3-43:17:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidInlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
[ThermoSysPro 3.2.0/WaterSteam/Connectors.mo:87:3-127:18:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidOutlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
[ThermoSysPro 3.2.0/Properties/C3H3F5/C3H3F5_Ph.mo:2:1-131:14:writable] Warning: pro.u was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/Properties/C3H3F5/C3H3F5_Ph.mo:2:1-131:14:writable] Warning: pro.cp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/Properties/C3H3F5/C3H3F5_Ph.mo:2:1-131:14:writable] Warning: pro.ddhp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/Properties/C3H3F5/C3H3F5_Ph.mo:2:1-131:14:writable] Warning: pro.ddph was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/Properties/C3H3F5/C3H3F5_Ph.mo:2:1-131:14:writable] Warning: pro.duph was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/Properties/C3H3F5/C3H3F5_Ph.mo:2:1-131:14:writable] Warning: pro.duhp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/Properties/WaterSteamSimple/prop4_Ph_der.mo:179:3-182:49:writable] Warning: du1satp_der was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/Properties/WaterSteamSimple/prop4_Ph_der.mo:179:3-182:49:writable] Warning: du2satp_der was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/Properties/WaterSteamSimple/prop4_Ph.mo:76:3-76:60:writable] Warning: dh1satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/Properties/WaterSteamSimple/prop4_Ph.mo:76:3-76:60:writable] Warning: dh2satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2.0/WaterSteam/Connectors.mo:3:3-43:17:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidInlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
[ThermoSysPro 3.2.0/WaterSteam/Connectors.mo:87:3-127:18:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidOutlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
[ThermoSysPro 3.2.0/WaterSteam/Connectors.mo:3:3-43:17:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidInlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
[ThermoSysPro 3.2.0/WaterSteam/Connectors.mo:3:3-43:17:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidInlet$FeedwaterValve$C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
[ThermoSysPro 3.2.0/WaterSteam/Connectors.mo:87:3-127:18:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidOutlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
[ThermoSysPro 3.2.0/WaterSteam/Connectors.mo:3:3-43:17:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidInlet$lumpedStraightPipe$C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
[ThermoSysPro 3.2.0/WaterSteam/Connectors.mo:87:3-127:18:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidOutlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts.
[BackEnd/SymbolicJacobian.mo:0:0-0:0:writable] Error: Internal error function generateSparsePattern failed
"
{"Files Equal!"}

Equation mismatch: diff says:
--- /tmp/omc-rtest-omtmpuser/simulation/libraries/3rdParty/ThermoSysPro/ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum.mos_temp3497/equations-expected2024-05-04 01:55:25.440430129 +0000
+++ /tmp/omc-rtest-omtmpuser/simulation/libraries/3rdParty/ThermoSysPro/ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum.mos_temp3497/equations-got2024-05-04 01:56:28.396829149 +0000
@@ -2,11 +2,11 @@
 ""
 true
 ""
 record SimulationResult
 resultFile = "ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum_res.mat",
-simulationOptions = "startTime = 0.0, stopTime = 1000.0, numberOfIntervals = 500, tolerance = 1e-06, method = 'dassl', fileNamePrefix = 'ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum', options = '', outputFormat = 'mat', variableFilter = '.*', cflags = '', simflags = ''",
+simulationOptions = "startTime = 0.0, stopTime = 1000.0, numberOfIntervals = 500, tolerance = 1e-6, method = 'dassl', fileNamePrefix = 'ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum', options = '', outputFormat = 'mat', variableFilter = '.*', cflags = '', simflags = ''",
 messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
 LOG_SUCCESS       | info    | The simulation finished successfully.
 "
 end SimulationResult;
 "[ThermoSysPro 3.2.0/WaterSteam/Connectors.mo:3:3-43:17:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidInlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
@@ -52,7 +52,8 @@
 [ThermoSysPro 3.2.0/WaterSteam/Connectors.mo:3:3-43:17:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidInlet$FeedwaterValve$C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
 [ThermoSysPro 3.2.0/WaterSteam/Connectors.mo:87:3-127:18:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidOutlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
 [ThermoSysPro 3.2.0/WaterSteam/Connectors.mo:3:3-43:17:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidInlet$lumpedStraightPipe$C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
 [ThermoSysPro 3.2.0/WaterSteam/Connectors.mo:87:3-127:18:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidOutlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
 Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts.
+[BackEnd/SymbolicJacobian.mo:0:0-0:0:writable] Error: Internal error function generateSparsePattern failed
 "
 {"Files Equal!"}

Equation mismatch: omc-diff says:
Failed '"' '['
Line 57: Text differs:
expected: "
got:      [BackEnd/SymbolicJacobian.mo:

== 1 out of 1 tests failed [simulation/libraries/3rdParty/ThermoSysPro/ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum.mos_temp3497, time: 63]