Skip to content

Failed

tests / 05 testsuite-clang 2/3 / simulation_libraries_msl32.Modelica.Magnetic.FundamentalWave.Examples.BasicMachines.AIMS_Start.mos (from (result.xml))

Failing for the past 44 builds (Since #1 )
Took 15 sec.

Stacktrace

Output mismatch (see stdout for details)

Standard Output

 + Modelica.Magnetic.FundamentalWave.Examples.BasicMachines.AIMS_Start               ... equation mismatch [time: 15]

==== Log /tmp/omc-rtest-unknown/simulation/libraries/msl32/Modelica.Magnetic.FundamentalWave.Examples.BasicMachines.AIMS_Start.mos_temp757/log-Modelica.Magnetic.FundamentalWave.Examples.BasicMachines.AIMS_Start.mos
"true
"
""
OpenModelicaModelTesting.Kind.VerifiedSimulation
Modelica.Magnetic.FundamentalWave.Examples.BasicMachines.AIMS_Start
{"aimsE.i_0_r","aimsE.i_0_s","aimsE.idq_rr[1]","aimsE.idq_rr[2]","aimsE.idq_sr[1]","aimsE.idq_sr[2]","aimsM.rotor.electroMagneticConverter.singlePhaseElectroMagneticConverter[1].Phi.re","aimsM.rotor.electroMagneticConverter.singlePhaseElectroMagneticConverter[2].Phi.im","aimsM.rotor.zeroInductor.i0","aimsM.stator.electroMagneticConverter.singlePhaseElectroMagneticConverter[1].Phi.re","aimsM.stator.electroMagneticConverter.singlePhaseElectroMagneticConverter[2].Phi.im","aimsM.stator.zeroInductor.i[1]","aimsM.stator.zeroInductor.i[2]","aimsM.stator.zeroInductor.i[3]","loadInertiaE.phi","loadInertiaE.w","loadInertiaM.phi","loadInertiaM.w"}
Simulation options: startTime = 0.0, stopTime = 1.5, numberOfIntervals = 1500, tolerance = 1e-5, method = 'dassl', fileNamePrefix = 'Modelica.Magnetic.FundamentalWave.Examples.BasicMachines.AIMS_Start', options = '', outputFormat = 'mat', variableFilter = 'time|aimsE.i_0_r|aimsE.i_0_s|aimsE.idq_rr.1.|aimsE.idq_rr.2.|aimsE.idq_sr.1.|aimsE.idq_sr.2.|aimsM.rotor.electroMagneticConverter.singlePhaseElectroMagneticConverter.1..Phi.re|aimsM.rotor.electroMagneticConverter.singlePhaseElectroMagneticConverter.2..Phi.im|aimsM.rotor.zeroInductor.i0|aimsM.stator.electroMagneticConverter.singlePhaseElectroMagneticConverter.1..Phi.re|aimsM.stator.electroMagneticConverter.singlePhaseElectroMagneticConverter.2..Phi.im|aimsM.stator.zeroInductor.i.1.|aimsM.stator.zeroInductor.i.2.|aimsM.stator.zeroInductor.i.3.|loadInertiaE.phi|loadInertiaE.w|loadInertiaM.phi|loadInertiaM.w', cflags = '', simflags = ' -abortSlowSimulation -alarm=360 -emit_protected'
Result file: Modelica.Magnetic.FundamentalWave.Examples.BasicMachines.AIMS_Start_res.mat
Messages: LOG_STDOUT        | info    | Using sparse solver for linear system 12,
|                 | |       | because density of 0.156 remains under threshold of 0.200.
LOG_STDOUT        | info    | Using sparse solver for linear system 14,
|                 | |       | because density of 0.173 remains under threshold of 0.200.
LOG_STDOUT        | info    | Using sparse solver for linear system 29,
|                 | |       | because density of 0.156 remains under threshold of 0.200.
LOG_STDOUT        | info    | The maximum density for using sparse solvers can be specified
|                 | |       | using the runtime flag '<-lssMaxDensity=value>'.
LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.

Files Equal!
"true
"
""

Equation mismatch: diff says:
--- /tmp/omc-rtest-unknown/simulation/libraries/msl32/Modelica.Magnetic.FundamentalWave.Examples.BasicMachines.AIMS_Start.mos_temp757/equations-expected2024-01-13 02:54:55.191171394 +0000
+++ /tmp/omc-rtest-unknown/simulation/libraries/msl32/Modelica.Magnetic.FundamentalWave.Examples.BasicMachines.AIMS_Start.mos_temp757/equations-got2024-01-13 02:55:10.519068060 +0000
@@ -2,13 +2,21 @@
 "
 ""
 OpenModelicaModelTesting.Kind.VerifiedSimulation
 Modelica.Magnetic.FundamentalWave.Examples.BasicMachines.AIMS_Start
 {"aimsE.i_0_r","aimsE.i_0_s","aimsE.idq_rr[1]","aimsE.idq_rr[2]","aimsE.idq_sr[1]","aimsE.idq_sr[2]","aimsM.rotor.electroMagneticConverter.singlePhaseElectroMagneticConverter[1].Phi.re","aimsM.rotor.electroMagneticConverter.singlePhaseElectroMagneticConverter[2].Phi.im","aimsM.rotor.zeroInductor.i0","aimsM.stator.electroMagneticConverter.singlePhaseElectroMagneticConverter[1].Phi.re","aimsM.stator.electroMagneticConverter.singlePhaseElectroMagneticConverter[2].Phi.im","aimsM.stator.zeroInductor.i[1]","aimsM.stator.zeroInductor.i[2]","aimsM.stator.zeroInductor.i[3]","loadInertiaE.phi","loadInertiaE.w","loadInertiaM.phi","loadInertiaM.w"}
-Simulation options: startTime = 0.0, stopTime = 1.5, numberOfIntervals = 1500, tolerance = 1e-05, method = 'dassl', fileNamePrefix = 'Modelica.Magnetic.FundamentalWave.Examples.BasicMachines.AIMS_Start', options = '', outputFormat = 'mat', variableFilter = 'time|aimsE.i_0_r|aimsE.i_0_s|aimsE.idq_rr.1.|aimsE.idq_rr.2.|aimsE.idq_sr.1.|aimsE.idq_sr.2.|aimsM.rotor.electroMagneticConverter.singlePhaseElectroMagneticConverter.1..Phi.re|aimsM.rotor.electroMagneticConverter.singlePhaseElectroMagneticConverter.2..Phi.im|aimsM.rotor.zeroInductor.i0|aimsM.stator.electroMagneticConverter.singlePhaseElectroMagneticConverter.1..Phi.re|aimsM.stator.electroMagneticConverter.singlePhaseElectroMagneticConverter.2..Phi.im|aimsM.stator.zeroInductor.i.1.|aimsM.stator.zeroInductor.i.2.|aimsM.stator.zeroInductor.i.3.|loadInertiaE.phi|loadInertiaE.w|loadInertiaM.phi|loadInertiaM.w', cflags = '', simflags = ' -abortSlowSimulation -alarm=360 -emit_protected'
+Simulation options: startTime = 0.0, stopTime = 1.5, numberOfIntervals = 1500, tolerance = 1e-5, method = 'dassl', fileNamePrefix = 'Modelica.Magnetic.FundamentalWave.Examples.BasicMachines.AIMS_Start', options = '', outputFormat = 'mat', variableFilter = 'time|aimsE.i_0_r|aimsE.i_0_s|aimsE.idq_rr.1.|aimsE.idq_rr.2.|aimsE.idq_sr.1.|aimsE.idq_sr.2.|aimsM.rotor.electroMagneticConverter.singlePhaseElectroMagneticConverter.1..Phi.re|aimsM.rotor.electroMagneticConverter.singlePhaseElectroMagneticConverter.2..Phi.im|aimsM.rotor.zeroInductor.i0|aimsM.stator.electroMagneticConverter.singlePhaseElectroMagneticConverter.1..Phi.re|aimsM.stator.electroMagneticConverter.singlePhaseElectroMagneticConverter.2..Phi.im|aimsM.stator.zeroInductor.i.1.|aimsM.stator.zeroInductor.i.2.|aimsM.stator.zeroInductor.i.3.|loadInertiaE.phi|loadInertiaE.w|loadInertiaM.phi|loadInertiaM.w', cflags = '', simflags = ' -abortSlowSimulation -alarm=360 -emit_protected'
 Result file: Modelica.Magnetic.FundamentalWave.Examples.BasicMachines.AIMS_Start_res.mat
-Messages: LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
+Messages: LOG_STDOUT        | info    | Using sparse solver for linear system 12,
+| | |       | because density of 0.156 remains under threshold of 0.200.
+LOG_STDOUT | info    | Using sparse solver for linear system 14,
+| | |       | because density of 0.173 remains under threshold of 0.200.
+LOG_STDOUT | info    | Using sparse solver for linear system 29,
+| | |       | because density of 0.156 remains under threshold of 0.200.
+LOG_STDOUT | info    | The maximum density for using sparse solvers can be specified
+| | |       | using the runtime flag '<-lssMaxDensity=value>'.
+LOG_SUCCESS | info    | The initialization finished successfully without homotopy method.
 LOG_SUCCESS       | info    | The simulation finished successfully.
 
 Files Equal!
 "true
 "

Equation mismatch: omc-diff says:
Failed 'U' 'T'
Line 9: Text differs:
expected: Messages: LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
got:      Messages: LOG_STDOUT        | info    | Using sparse solver for linear system 

== 1 out of 1 tests failed [simulation/libraries/msl32/Modelica.Magnetic.FundamentalWave.Examples.BasicMachines.AIMS_Start.mos_temp757, time: 15]