Skip to content

Failed

tests / 02 testsuite-gcc 2/3 / simulation_libraries_msl32.Modelica.Electrical.Machines.Examples.Transformers.AIMC_Transformer.mos (from (result.xml))

Failing for the past 44 builds (Since #1 )
Took 27 sec.

Stacktrace

Output mismatch (see stdout for details)

Standard Output

 + Modelica.Electrical.Machines.Examples.Transformers.AIMC_Transformer               ... equation mismatch [time: 27]

==== Log /tmp/omc-rtest-unknown/simulation/libraries/msl32/Modelica.Electrical.Machines.Examples.Transformers.AIMC_Transformer.mos_temp5518/log-Modelica.Electrical.Machines.Examples.Transformers.AIMC_Transformer.mos
"true
"
""
0.015
OpenModelicaModelTesting.Kind.SimpleSimulation
Modelica.Electrical.Machines.Examples.Transformers.AIMC_Transformer
{"aimc.idq_rr[1]","aimc.idq_rr[2]","aimc.lssigma.i_[1]","aimc.lssigma.i_[2]","aimc.lszero.i","loadInertia.phi","loadInertia.w","transformer.l1sigma.inductor[2].i","transformer.l1sigma.inductor[3].i"}
Simulation options: startTime = 0.0, stopTime = 2.5, numberOfIntervals = 2500, tolerance = 1e-6, method = 'dassl', fileNamePrefix = 'Modelica.Electrical.Machines.Examples.Transformers.AIMC_Transformer', options = '', outputFormat = 'mat', variableFilter = 'time|aimc.idq_rr.1.|aimc.idq_rr.2.|aimc.lssigma.i_.1.|aimc.lssigma.i_.2.|aimc.lszero.i|loadInertia.phi|loadInertia.w|transformer.l1sigma.inductor.2..i|transformer.l1sigma.inductor.3..i', cflags = '', simflags = ' -abortSlowSimulation -alarm=360 -emit_protected'
Result file: Modelica.Electrical.Machines.Examples.Transformers.AIMC_Transformer_res.mat
Messages: LOG_STDOUT        | info    | Using sparse solver for linear system 0,
|                 | |       | because density of 0.080 remains under threshold of 0.200.
LOG_STDOUT        | info    | Using sparse solver for linear system 3,
|                 | |       | because density of 0.184 remains under threshold of 0.200.
LOG_STDOUT        | info    | Using sparse solver for linear system 6,
|                 | |       | because density of 0.080 remains under threshold of 0.200.
LOG_STDOUT        | info    | Using sparse solver for linear system 8,
|                 | |       | because density of 0.184 remains under threshold of 0.200.
LOG_STDOUT        | info    | The maximum density for using sparse solvers can be specified
|                 | |       | using the runtime flag '<-lssMaxDensity=value>'.
LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.

"true
"
""

Equation mismatch: diff says:
--- /tmp/omc-rtest-unknown/simulation/libraries/msl32/Modelica.Electrical.Machines.Examples.Transformers.AIMC_Transformer.mos_temp5518/equations-expected2024-01-13 02:58:53.458336715 +0000
+++ /tmp/omc-rtest-unknown/simulation/libraries/msl32/Modelica.Electrical.Machines.Examples.Transformers.AIMC_Transformer.mos_temp5518/equations-got2024-01-13 02:59:20.182537727 +0000
@@ -3,13 +3,23 @@
 ""
 0.015
 OpenModelicaModelTesting.Kind.SimpleSimulation
 Modelica.Electrical.Machines.Examples.Transformers.AIMC_Transformer
 {"aimc.idq_rr[1]","aimc.idq_rr[2]","aimc.lssigma.i_[1]","aimc.lssigma.i_[2]","aimc.lszero.i","loadInertia.phi","loadInertia.w","transformer.l1sigma.inductor[2].i","transformer.l1sigma.inductor[3].i"}
-Simulation options: startTime = 0.0, stopTime = 2.5, numberOfIntervals = 2500, tolerance = 1e-06, method = 'dassl', fileNamePrefix = 'Modelica.Electrical.Machines.Examples.Transformers.AIMC_Transformer', options = '', outputFormat = 'mat', variableFilter = 'time|aimc.idq_rr.1.|aimc.idq_rr.2.|aimc.lssigma.i_.1.|aimc.lssigma.i_.2.|aimc.lszero.i|loadInertia.phi|loadInertia.w|transformer.l1sigma.inductor.2..i|transformer.l1sigma.inductor.3..i', cflags = '', simflags = ' -abortSlowSimulation -alarm=360 -emit_protected'
+Simulation options: startTime = 0.0, stopTime = 2.5, numberOfIntervals = 2500, tolerance = 1e-6, method = 'dassl', fileNamePrefix = 'Modelica.Electrical.Machines.Examples.Transformers.AIMC_Transformer', options = '', outputFormat = 'mat', variableFilter = 'time|aimc.idq_rr.1.|aimc.idq_rr.2.|aimc.lssigma.i_.1.|aimc.lssigma.i_.2.|aimc.lszero.i|loadInertia.phi|loadInertia.w|transformer.l1sigma.inductor.2..i|transformer.l1sigma.inductor.3..i', cflags = '', simflags = ' -abortSlowSimulation -alarm=360 -emit_protected'
 Result file: Modelica.Electrical.Machines.Examples.Transformers.AIMC_Transformer_res.mat
-Messages: LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
+Messages: LOG_STDOUT        | info    | Using sparse solver for linear system 0,
+| | |       | because density of 0.080 remains under threshold of 0.200.
+LOG_STDOUT | info    | Using sparse solver for linear system 3,
+| | |       | because density of 0.184 remains under threshold of 0.200.
+LOG_STDOUT | info    | Using sparse solver for linear system 6,
+| | |       | because density of 0.080 remains under threshold of 0.200.
+LOG_STDOUT | info    | Using sparse solver for linear system 8,
+| | |       | because density of 0.184 remains under threshold of 0.200.
+LOG_STDOUT | info    | The maximum density for using sparse solvers can be specified
+| | |       | using the runtime flag '<-lssMaxDensity=value>'.
+LOG_SUCCESS | info    | The initialization finished successfully without homotopy method.
 LOG_SUCCESS       | info    | The simulation finished successfully.
 
 "true
 "
 ""

Equation mismatch: omc-diff says:
Failed 'U' 'T'
Line 10: Text differs:
expected: Messages: LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
got:      Messages: LOG_STDOUT        | info    | Using sparse solver for linear system 

== 1 out of 1 tests failed [simulation/libraries/msl32/Modelica.Electrical.Machines.Examples.Transformers.AIMC_Transformer.mos_temp5518, time: 27]