Failed
tests / 01 testsuite-gcc 1/3 / omsimulator.testDirectionalDerivatives.mos (from (result.xml))
Stacktrace
Output mismatch (see stdout for details)
Standard Output
+ testDirectionalDerivatives ... equation mismatch [time: 12] ==== Log /tmp/omc-rtest-unknown/omsimulator/testDirectionalDerivatives.mos_temp6020/log-testDirectionalDerivatives.mos true "" true "" "Modelica.Electrical.Analog.Examples.CauerLowPassAnalog.fmu" "" true "" 0 "LOG_STDOUT | info | Using sparse solver for linear system 0, | | | | because density of 0.188 remains under threshold of 0.200. LOG_STDOUT | info | The simulation runtime does not have access to sparse solvers. Defaulting to a dense linear system solver instead. LOG_STDOUT | info | The maximum density for using sparse solvers can be specified | | | | using the runtime flag '<-lssMaxDensity=value>'. info: maximum step size for 'test.root': 0.001000 info: Result file: directionalDerivatives.csv (bufferSize=1) info: Initialization info: system1.C1.v: 0.0 info: Simulation info: system1.C1.v: 0.0 info: Final Statistics for 'test.root': NumSteps = 1001 NumRhsEvals = 1002 NumLinSolvSetups = 51 NumNonlinSolvIters = 1001 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 " Equation mismatch: diff says: --- /tmp/omc-rtest-unknown/omsimulator/testDirectionalDerivatives.mos_temp6020/equations-expected2024-01-13 02:52:54.692711194 +0000 +++ /tmp/omc-rtest-unknown/omsimulator/testDirectionalDerivatives.mos_temp6020/equations-got2024-01-13 02:53:06.048802841 +0000 @@ -5,11 +5,16 @@ "Modelica.Electrical.Analog.Examples.CauerLowPassAnalog.fmu" "" true "" 0 -"info: maximum step size for 'test.root': 0.001000 +"LOG_STDOUT | info | Using sparse solver for linear system 0, +| | | | because density of 0.188 remains under threshold of 0.200. +LOG_STDOUT | info | The simulation runtime does not have access to sparse solvers. Defaulting to a dense linear system solver instead. +LOG_STDOUT | info | The maximum density for using sparse solvers can be specified +| | | | using the runtime flag '<-lssMaxDensity=value>'. +info: maximum step size for 'test.root': 0.001000 info: Result file: directionalDerivatives.csv (bufferSize=1) info: Initialization info: system1.C1.v: 0.0 info: Simulation info: system1.C1.v: 0.0 Equation mismatch: omc-diff says: Failed 'i' 'L' Line 10: Text differs: expected: "info: maximum step size for 'test.root': got: "LOG_STDOUT | info | Using sparse solver for linear system == 1 out of 1 tests failed [omsimulator/testDirectionalDerivatives.mos_temp6020, time: 12]