Skip to content

Console Output

+ make -C testsuite/special/FmuExportCrossCompile/ test
make: Entering directory '/var/lib/jenkins/ws/OpenModelica_PR-10104/testsuite/special/FmuExportCrossCompile'
rm -rf *.json *.xml *.html *.fmu* *.c *.makefile *.log *.o *.libs *.h *.mat *.csv Test_FMUs
rm -rf CMakeCrossCompile/
make fmuExportCrossCompile
make[1]: Entering directory '/var/lib/jenkins/ws/OpenModelica_PR-10104/testsuite/special/FmuExportCrossCompile'
HOME=/var/lib/jenkins/ws/OpenModelica_PR-10104/testsuite/special/FmuExportCrossCompile/../../../libraries/ ../../../build/bin/omc fmuExportCrossCompile.mos

"Warning: Requested package Modelica of version 4.0.0, but this package was already loaded with version 3.2.3. There are no conversion annotations for this version but 4.0.0 is newer than 3.2.3. There is a possibility that 3.2.3 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
"

""

""

""

""
{"x86_64-apple-darwin15 docker run docker.openmodelica.org/osxcross-omsimulator:v2.0","arm-linux-gnueabihf docker run docker.openmodelica.org/armcross-omsimulator:v2.0","x86_64-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13","i686-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13-i386","x86_64-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0","i686-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0"}
FmuExportCrossCompile
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: Requested package Complex of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package ModelicaServices of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package Modelica of version 4.0.0, but this package was already loaded with version 3.2.3. There are no conversion annotations for this version but 4.0.0 is newer than 3.2.3. There is a possibility that 3.2.3 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.


record SimulationResult
    resultFile = "/var/lib/jenkins/ws/OpenModelica_PR-10104/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 0.45, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'FmuExportCrossCompile', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.06874195600000001,
    timeBackend = 0.084864065,
    timeSimCode = 0.000581841,
    timeTemplates = 0.001758027,
    timeCompile = 0.291950715,
    timeSimulation = 0.015307852,
    timeTotal = 0.4632976110000001
end SimulationResult;
"Warning: Requested package Complex of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package ModelicaServices of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package Modelica of version 4.0.0, but this package was already loaded with version 3.2.3. There are no conversion annotations for this version but 4.0.0 is newer than 3.2.3. There is a possibility that 3.2.3 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
"

true
""
"/var/lib/jenkins/ws/OpenModelica_PR-10104/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile.fmu"


RoomHeating_OM_RH

701f107ec8194a8137a967c81c3dbf0fe49df3ca0b5de4bce91998cfd5c8caed
cb255eee25b5893f67da80525fdeac4f16544133bdf99d3a80b22d78313706fe
c7e6a3efe484a98048efe0ef64819020c275dba687beb419a98ac3393e8612b0
d1ccf6f1d76e46a7160ea86fd0c2fe3d87916f4b552cb9905b05653381a244cc
8125b45f69a1bda2a1edd6bc31debd4a3353f77b012286aa2591f20b06a3e2de
adf0ec88073db55a7e28e11cd6dce1acb6a367f3d629286f2aa1d5e6bc0b4ce6
1877616ad31888b9fe8893455d3caf81edc8aeb6a455f051976055b9491264b0
3c89150cb15c2cccb9a9a289dde52c7ee11dbc03c511d473f8b993f7b3bc6b93
49c3aa4c8cd2d3766ad0a1039d7a9175cb8a9d39500b21787a47c5f0c551e1e0
669edd1fa414be93ede79a6c0a4bc3fddb050dfa9f60b7087a85dfcdddb43207
8a225f10186b92cd6ef84f1952f5e9ec55f913f43244bf71a9bd78dbe45fe586
04f4bd4796f001ade7744359bd465d35b063c2c76c702ff9187e1881dac695db
Warning: Requested package Complex of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package ModelicaServices of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package Modelica of version 4.0.0, but this package was already loaded with version 3.2.3. There are no conversion annotations for this version but 4.0.0 is newer than 3.2.3. There is a possibility that 3.2.3 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->Show additional information from the initialization process, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins/ws/OpenModelica_PR-10104/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'RoomHeating_OM_RH', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "assert            | warning | [/var/lib/jenkins/ws/OpenModelica_PR-10104/testsuite/special/FmuExportCrossCompile/RoomHeating_OM.mo:69:5-69:117:writable]
|                 | |       | The following assertion has been violated during initialization at time 0.000000
|                 | |       | ((fanspeed >= 0.01)) --> \"UTRC-FCU-002: FCU air damper should be opened at least 0.10.\"
LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.063006097,
    timeBackend = 0.006584691,
    timeSimCode = 0.001232442,
    timeTemplates = 0.003145039,
    timeCompile = 0.344952908,
    timeSimulation = 0.029916112,
    timeTotal = 0.448927097
end SimulationResult;
"Warning: Requested package Complex of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package ModelicaServices of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package Modelica of version 4.0.0, but this package was already loaded with version 3.2.3. There are no conversion annotations for this version but 4.0.0 is newer than 3.2.3. There is a possibility that 3.2.3 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->Show additional information from the initialization process, in OMNotebook call setCommandLineOptions(\"-d=initialization\").
"

true
""
"/var/lib/jenkins/ws/OpenModelica_PR-10104/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH.fmu"


WaterTank_Control
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: Requested package Complex of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package ModelicaServices of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package Modelica of version 4.0.0, but this package was already loaded with version 3.2.3. There are no conversion annotations for this version but 4.0.0 is newer than 3.2.3. There is a possibility that 3.2.3 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->Show additional information from the initialization process, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins/ws/OpenModelica_PR-10104/testsuite/special/FmuExportCrossCompile/WaterTank_Control_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'WaterTank_Control', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.062846918,
    timeBackend = 0.001079134,
    timeSimCode = 0.000368411,
    timeTemplates = 0.001729904,
    timeCompile = 0.263259401,
    timeSimulation = 0.016697048,
    timeTotal = 0.3460680899999999
end SimulationResult;
"Warning: Requested package Complex of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package ModelicaServices of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package Modelica of version 4.0.0, but this package was already loaded with version 3.2.3. There are no conversion annotations for this version but 4.0.0 is newer than 3.2.3. There is a possibility that 3.2.3 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->Show additional information from the initialization process, in OMNotebook call setCommandLineOptions(\"-d=initialization\").
"

true
""
"/var/lib/jenkins/ws/OpenModelica_PR-10104/testsuite/special/FmuExportCrossCompile/WaterTank_Control.fmu"


WaterTank_TestSingleWaterTank

74488b9fa783e43997aeb5fb27acde81bea477ab4ae1f83de74188df9fc1ef91
d4293cf2efd962646f81e70399dc540d20d860f397d16618ae166badab10e555
c3c413282d1e696ecf6caf4692813c69caea09e56b7e828753d1f142ea3102b2
5f044b4a3c034c18ec63bc645325fe4e07724a031d253ef672559685350e9dcb
d10899352acbfc6d54d9318f4c1dcd265b3773e9b110beab16d325d3aa7b7257
1a8f3eb65b03b1fd4c11a4a6e175672e97221e8d95a9a33e3c702123c548bd50
c81f986dc0a20ea075e4546631ab78f98ccef6057e522b629162a1cf56ea53c1
5b7ed997be1c35ececd7bc5a89e40be95753918b63bfd9dfe1c9c17b82b769b7
26681d8ee59681283f395c0dbd4c7745889a6201e369cd83174b140f61aa8f08
7edeeb41c999c9145c298772fce4eed38bdb7ef8a4734f599bea1a17fbbcf965
f20e371a70be3cd7d0cc26fbd073741ed078b794bef0c010d2b0b96558e90dd0
1a0cf04f4975d12c43b006dd8f04711085d9378208a20fb871d0ca3890870147
Warning: Requested package Complex of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package ModelicaServices of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package Modelica of version 4.0.0, but this package was already loaded with version 3.2.3. There are no conversion annotations for this version but 4.0.0 is newer than 3.2.3. There is a possibility that 3.2.3 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
[/var/lib/jenkins/ws/OpenModelica_PR-10104/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation tank.valvecontrol <> 0.0, <> on Real numbers is only allowed inside functions.
[/var/lib/jenkins/ws/OpenModelica_PR-10104/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation tank.valvecontrol <> 0.0, <> on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->Show additional information from the initialization process, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins/ws/OpenModelica_PR-10104/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'WaterTank_TestSingleWaterTank', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.062402996,
    timeBackend = 0.003051754,
    timeSimCode = 0.000754565,
    timeTemplates = 0.00226624,
    timeCompile = 0.29299796,
    timeSimulation = 0.020726255,
    timeTotal = 0.382262328
end SimulationResult;
"Warning: Requested package Complex of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package ModelicaServices of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package Modelica of version 4.0.0, but this package was already loaded with version 3.2.3. There are no conversion annotations for this version but 4.0.0 is newer than 3.2.3. There is a possibility that 3.2.3 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
[/var/lib/jenkins/ws/OpenModelica_PR-10104/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation tank.valvecontrol <> 0.0, <> on Real numbers is only allowed inside functions.
[/var/lib/jenkins/ws/OpenModelica_PR-10104/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation tank.valvecontrol <> 0.0, <> on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->Show additional information from the initialization process, in OMNotebook call setCommandLineOptions(\"-d=initialization\").
"

true
""
"/var/lib/jenkins/ws/OpenModelica_PR-10104/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank.fmu"


BouncingBall

ba3a4df6398f6d6e07a8bc7d992c23aa4bc12a855beae3be38fc4730a8914f09
2dc0ff5ebdf068eee5e519813ff6b2c0a562a22064302424c539b38e169622ec
d689350f6f91f69961d000ba14de1dba9099be3f414f2d025d642d79a726f6b6
521a4eb08b1a55c8c75f8c9ef6182869ebf71858c6f3125212dc7ceacc89de80
26ec36ebb29d2f700af651033b3cea31102f6897ec42be3ad32cfc61245d2877
a071f8e8b051025c461374e0087724ef84c316d9785a506ed19b03096de91a10
64f8d873e8e5e0e5118d0ec4dcf6380f2242c574e0d082634fd9629f745746b0
34971a9e0621fee127024d89c03ffbfdc032d447b44a76ee70d89da12b1d476e
a04dc0cc92b8fc4863ce4f1dafcf23df61663960b7cff843c8ff8ba33eaf6877
5f4781ed9efb0b2792cfe287a273fd49024e2c117ae6072a00108b9a70bf0bce
9e9d04741fba11bab36cdac59f9c4b27b7e16e00e53c3c478233a80531633046
b5d898480d3fe5b6737f56657d7428b77ba38bd265ec59582b7dc9473a163709
Warning: Requested package Complex of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package ModelicaServices of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package Modelica of version 4.0.0, but this package was already loaded with version 3.2.3. There are no conversion annotations for this version but 4.0.0 is newer than 3.2.3. There is a possibility that 3.2.3 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.


record SimulationResult
    resultFile = "/var/lib/jenkins/ws/OpenModelica_PR-10104/testsuite/special/FmuExportCrossCompile/BouncingBall_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'BouncingBall', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.067790842,
    timeBackend = 0.002090692,
    timeSimCode = 0.000685927,
    timeTemplates = 0.002014379,
    timeCompile = 0.310637104,
    timeSimulation = 0.014471403,
    timeTotal = 0.397765526
end SimulationResult;
"Warning: Requested package Complex of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package ModelicaServices of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package Modelica of version 4.0.0, but this package was already loaded with version 3.2.3. There are no conversion annotations for this version but 4.0.0 is newer than 3.2.3. There is a possibility that 3.2.3 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
"

true
""
"/var/lib/jenkins/ws/OpenModelica_PR-10104/testsuite/special/FmuExportCrossCompile/BouncingBall.fmu"



unzip -q FmuExportCrossCompile.fmu -d FmuExportCrossCompile.fmutmp
make check-FmuExportCrossCompile-files
make[2]: Entering directory '/var/lib/jenkins/ws/OpenModelica_PR-10104/testsuite/special/FmuExportCrossCompile'
FmuExportCrossCompile.fmutmp/binaries/win32/FmuExportCrossCompile.dll: PE32 executable (DLL) (console) Intel 80386, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/win64/FmuExportCrossCompile.dll: PE32+ executable (DLL) (console) x86-64, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/darwin64/FmuExportCrossCompile.dylib: Mach-O 64-bit x86_64 dynamically linked shared library, flags:<NOUNDEFS|DYLDLINK|TWOLEVEL|NO_REEXPORTED_DYLIBS>
FmuExportCrossCompile.fmutmp/binaries/linux32/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, Intel 80386, version 1 (SYSV), dynamically linked, BuildID[sha1]=4cc767a7022a85556b0f961ccb9b753d085c87e1, not stripped
FmuExportCrossCompile.fmutmp/binaries/linux64/FmuExportCrossCompile.so: ELF 64-bit LSB shared object, x86-64, version 1 (SYSV), dynamically linked, BuildID[sha1]=f878e427a6eb755cf1e14961f53ffda96eed539f, not stripped
FmuExportCrossCompile.fmutmp/binaries/arm-linux-gnueabihf/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, ARM, EABI5 version 1 (SYSV), dynamically linked, BuildID[sha1]=46079bf8297ed4393f7b993a40deddb6a2bbedec, not stripped
make[2]: Leaving directory '/var/lib/jenkins/ws/OpenModelica_PR-10104/testsuite/special/FmuExportCrossCompile'
make[1]: Leaving directory '/var/lib/jenkins/ws/OpenModelica_PR-10104/testsuite/special/FmuExportCrossCompile'
make CMakeCrossCompile
make[1]: Entering directory '/var/lib/jenkins/ws/OpenModelica_PR-10104/testsuite/special/FmuExportCrossCompile'
HOME=/var/lib/jenkins/ws/OpenModelica_PR-10104/testsuite/special/FmuExportCrossCompile/../../../libraries/ ../../../build/bin/omc CMakeCrossCompile.mos

0
"/var/lib/jenkins/ws/OpenModelica_PR-10104/testsuite/special/FmuExportCrossCompile/CMakeCrossCompile"

{"x86_64-apple-darwin docker run multiarch/crossbuild","x86_64-linux-gnu docker run multiarch/crossbuild","i686-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13-i386","x86_64-w64-mingw32 docker run multiarch/crossbuild","i686-w64-mingw32 docker run multiarch/crossbuild"}
830d8a1b5b4c1275de8de3c4e88459627793c348a6abba24be9dc648768954be
78b0e83441e6bbbec55a60c8a2df8a4603e3673190e71e71441e4488903812e3
7fb7fa54ae189b9fec98764ed2746e9606957c1f28ad8756b1a84367dd636514
e3d6ca0fad8d4498f086c63c6d66cff75162d2ad33319cde359f3e95434d4ceb
33b826d4861db1f0e50c4b04c5afe0548f2e03b31d426086a8b5fbda5e8b2617
a11ec0586e4b0136a56aacd75591ee4efb816a977cf79127079d5ac0b062fb93
01f33355cb882d443741a53829069a9e181686db407642dab0ad2049cd61aef4
24791f44f989910ea0645540fe2203be6cecaf8e15f84b1b45a69ef92a6244c5
5597f4c91abc64bc7c5816872272ba1d6efec6a223009ced813e20c78e86a18c
8cf8ba1624bd98303da9b81caec5e552ebbaa0dd4a1b2ea7d0f369c2c971502d
"/var/lib/jenkins/ws/OpenModelica_PR-10104/testsuite/special/FmuExportCrossCompile/CMakeCrossCompile/Modelica.Mechanics.MultiBody.Examples.Elementary.Pendulum.fmu"
""
unzip -qq CMakeCrossCompile/Modelica.Mechanics.MultiBody.Examples.Elementary.Pendulum.fmu -d CMakeCrossCompile/Pendulum_FMU/
make check-CMakeCrossCompile-files
make[2]: Entering directory '/var/lib/jenkins/ws/OpenModelica_PR-10104/testsuite/special/FmuExportCrossCompile'
CMakeCrossCompile/Pendulum_FMU/binaries/win32/Modelica_Mechanics_MultiBody_Examples_Elementary_Pendulum.dll: PE32 executable (DLL) (console) Intel 80386, for MS Windows
CMakeCrossCompile/Pendulum_FMU/binaries/win64/Modelica_Mechanics_MultiBody_Examples_Elementary_Pendulum.dll: PE32+ executable (DLL) (console) x86-64, for MS Windows
CMakeCrossCompile/Pendulum_FMU/binaries/darwin64/Modelica_Mechanics_MultiBody_Examples_Elementary_Pendulum.dylib: Mach-O 64-bit x86_64 dynamically linked shared library, flags:<NOUNDEFS|DYLDLINK|TWOLEVEL|NO_REEXPORTED_DYLIBS>
CMakeCrossCompile/Pendulum_FMU/binaries/linux32/Modelica_Mechanics_MultiBody_Examples_Elementary_Pendulum.so: ELF 32-bit LSB shared object, Intel 80386, version 1 (SYSV), dynamically linked, BuildID[sha1]=1098c7789a17f75abb89c030b79334c93f27fba1, with debug_info, not stripped
CMakeCrossCompile/Pendulum_FMU/binaries/linux64/Modelica_Mechanics_MultiBody_Examples_Elementary_Pendulum.so: ELF 64-bit LSB shared object, x86-64, version 1 (SYSV), dynamically linked, BuildID[sha1]=c44b42c580610bb51a115282b60de7f7c47bd66d, with debug_info, not stripped
make[2]: Leaving directory '/var/lib/jenkins/ws/OpenModelica_PR-10104/testsuite/special/FmuExportCrossCompile'
make[1]: Leaving directory '/var/lib/jenkins/ws/OpenModelica_PR-10104/testsuite/special/FmuExportCrossCompile'
make: Leaving directory '/var/lib/jenkins/ws/OpenModelica_PR-10104/testsuite/special/FmuExportCrossCompile'