Skip to content

Console Output

+ make -C testsuite/special/FmuExportCrossCompile/ test
make: Entering directory '/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.22/testsuite/special/FmuExportCrossCompile'
rm -rf *.json *.xml *.html *.fmu* *.c *.makefile *.log *.o *.opt *.libs *.h *.mat *.csv
rm -f BouncingBall FmuExportCrossCompile RoomHeating_OM_RH WaterTank_Control WaterTank_TestSingleWaterTank
rm -rf CMakeCrossCompile/ Test_FMUs/
make fmuExportCrossCompile
make[1]: Entering directory '/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.22/testsuite/special/FmuExportCrossCompile'
HOME=/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.22/testsuite/special/FmuExportCrossCompile/../../../libraries/ ../../../build/bin/omc fmuExportCrossCompile.mos

"Warning: Requested package Modelica of version 4.0.0, but this package was already loaded with version 3.2.3. There are no conversion annotations for this version but 4.0.0 is newer than 3.2.3. There is a possibility that 3.2.3 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
"

""

""

""

""
{"x86_64-apple-darwin15 docker run docker.openmodelica.org/osxcross-omsimulator:v2.0","arm-linux-gnueabihf docker run docker.openmodelica.org/armcross-omsimulator:v2.0","x86_64-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13","i686-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13-i386","x86_64-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0","i686-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0"}
FmuExportCrossCompile

55cd84eaec0e69dc1eab7c484c651b44e578079dd331c20cd4edcbacaf84f82e
83dc32554dd3983f5fbdc2ca3526cfd523e0331f2bcd49aabc5ccd349cfeb20e
302151d92fa85cdc9e81c67f7a4cbc05f1fcb65417c2cf5f87f1179b076609e1
16f81bec384bdd0f55d490c5db5b097033f00210df63a46ff02562e7fb604156
47c4fac31c19192ee3729acb2684327902e57300968c771058091efeef09e8c1
3efd5b1cd40aff01b0bce32202e392988295d6e8ef9df83de2ab7511d53c4c57
5fe1c9e34c26785ab61aabc33a64e790d07c674b1a4f665473bb0a9cf3a3a8da
d055929c6dc4af86cee7244682f81a826e85092a17facc22bb062b8a64b8e221
ad90a82cda1c13bc259b392bb8c6edda4596d07b7b22830868e7e7563011cef2
6468dffa8de3cb9b46a669c5c4b523323638eb6bd568598d25205586ce843e3a
302e2c2536b7496ec05d7a004a6bb4c003ffaa787a2f2c86649d56fde9e2530e
db99f03ff5181da8c3200b151d5e913cbee480a6e88151219a07df51437e2d3d
Warning: Requested package Complex of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package ModelicaServices of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package Modelica of version 4.0.0, but this package was already loaded with version 3.2.3. There are no conversion annotations for this version but 4.0.0 is newer than 3.2.3. There is a possibility that 3.2.3 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
Notification: The Makefile build for FMUs is deprecated and will be removed in a future version of OpenModelica. Use "--fmuCMakeBuild=true".


record SimulationResult
    resultFile = "/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.22/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 0.45, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'FmuExportCrossCompile', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.160661334,
    timeBackend = 0.006527514000000001,
    timeSimCode = 0.001972874,
    timeTemplates = 0.004179787,
    timeCompile = 0.6871977460000001,
    timeSimulation = 0.028464385,
    timeTotal = 0.8891977209999999
end SimulationResult;
"Warning: Requested package Complex of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package ModelicaServices of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package Modelica of version 4.0.0, but this package was already loaded with version 3.2.3. There are no conversion annotations for this version but 4.0.0 is newer than 3.2.3. There is a possibility that 3.2.3 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
"

true
""
"/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.22/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile.fmu"


RoomHeating_OM_RH
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: Requested package Complex of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package ModelicaServices of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package Modelica of version 4.0.0, but this package was already loaded with version 3.2.3. There are no conversion annotations for this version but 4.0.0 is newer than 3.2.3. There is a possibility that 3.2.3 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->Show additional information from the initialization process, in OMNotebook call setCommandLineOptions("-d=initialization").
Notification: The Makefile build for FMUs is deprecated and will be removed in a future version of OpenModelica. Use "--fmuCMakeBuild=true".


record SimulationResult
    resultFile = "/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.22/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'RoomHeating_OM_RH', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_ASSERT        | warning | [/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.22/testsuite/special/FmuExportCrossCompile/RoomHeating_OM.mo:69:5-69:117:writable]
|                 | |       | The following assertion has been violated during initialization at time 0.000000
|                 | |       | ((fanspeed >= 0.01)) --> \"UTRC-FCU-002: FCU air damper should be opened at least 0.10.\"
LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.269998177,
    timeBackend = 0.020053635,
    timeSimCode = 0.003235657,
    timeTemplates = 0.005230781,
    timeCompile = 0.7628914370000001,
    timeSimulation = 0.061683725,
    timeTotal = 1.123233534
end SimulationResult;
"Warning: Requested package Complex of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package ModelicaServices of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package Modelica of version 4.0.0, but this package was already loaded with version 3.2.3. There are no conversion annotations for this version but 4.0.0 is newer than 3.2.3. There is a possibility that 3.2.3 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->Show additional information from the initialization process, in OMNotebook call setCommandLineOptions(\"-d=initialization\").
"

true
""
"/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.22/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH.fmu"


WaterTank_Control
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: Requested package Complex of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package ModelicaServices of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package Modelica of version 4.0.0, but this package was already loaded with version 3.2.3. There are no conversion annotations for this version but 4.0.0 is newer than 3.2.3. There is a possibility that 3.2.3 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->Show additional information from the initialization process, in OMNotebook call setCommandLineOptions("-d=initialization").
Notification: The Makefile build for FMUs is deprecated and will be removed in a future version of OpenModelica. Use "--fmuCMakeBuild=true".


record SimulationResult
    resultFile = "/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.22/testsuite/special/FmuExportCrossCompile/WaterTank_Control_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'WaterTank_Control', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.170454367,
    timeBackend = 0.003710864,
    timeSimCode = 0.00121548,
    timeTemplates = 0.135240687,
    timeCompile = 0.650607275,
    timeSimulation = 0.024627949,
    timeTotal = 0.986117003
end SimulationResult;
"Warning: Requested package Complex of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package ModelicaServices of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package Modelica of version 4.0.0, but this package was already loaded with version 3.2.3. There are no conversion annotations for this version but 4.0.0 is newer than 3.2.3. There is a possibility that 3.2.3 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->Show additional information from the initialization process, in OMNotebook call setCommandLineOptions(\"-d=initialization\").
"

true
""
"/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.22/testsuite/special/FmuExportCrossCompile/WaterTank_Control.fmu"


WaterTank_TestSingleWaterTank

937fca230c516db1fb8f2d6df61b2f22e2f269d44840531836645bf720c5de5f
79d0e237555585e4472b91efce74119e376de2c0ce920c6e62e9df89aad9c03a
2b3aa322198117c806023a865f43a7b69feecb3f038b9dfcde9b6f11f35f8658
c232a4ed4616e0b4046cf2d861e1bee6cd03543a89213f7c7539d86561452d08
6ba737b1ba289b3db62208bbfd06fb788c92bec3e2e4276be7e260bfce769927
16d1577b3014bb9200f86ba1c302e770831152f3b1c63b99ea297b1264450aa4
b2d6e00df570cdb82bf271b0d4f13f7aa9b21422bff7d1641476bef222bbb98d
a6ba3ee91a18bfd88c596b416245e1dbf408817754471d160d460360dd9e66fe
c79ae3c01b2873ea1d8268d93425df09e79be1a0f8b336e2719d293a0c3ab045
92959d88c1a80f5122a53f82b82f31569450d42ccde9f8d3a84aa2d5ae8c4821
da399d20db8c6f3ed6cf8be6ce509a4fa0ee16d980a6184be0d5ea369cc0d3e6
2d35290ab986ae37e0bf8adb76a9dadb8c425ff4809e2a151964e15ae16e5c28
Warning: Requested package Complex of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package ModelicaServices of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package Modelica of version 4.0.0, but this package was already loaded with version 3.2.3. There are no conversion annotations for this version but 4.0.0 is newer than 3.2.3. There is a possibility that 3.2.3 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
[/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.22/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation tank.valvecontrol <> 0.0, <> on Real numbers is only allowed inside functions.
[/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.22/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation tank.valvecontrol <> 0.0, <> on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->Show additional information from the initialization process, in OMNotebook call setCommandLineOptions("-d=initialization").
Notification: The Makefile build for FMUs is deprecated and will be removed in a future version of OpenModelica. Use "--fmuCMakeBuild=true".


record SimulationResult
    resultFile = "/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.22/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'WaterTank_TestSingleWaterTank', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.145912097,
    timeBackend = 0.010895161,
    timeSimCode = 0.002553766,
    timeTemplates = 0.004465645,
    timeCompile = 0.685930378,
    timeSimulation = 0.040121016,
    timeTotal = 0.890063899
end SimulationResult;
"Warning: Requested package Complex of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package ModelicaServices of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package Modelica of version 4.0.0, but this package was already loaded with version 3.2.3. There are no conversion annotations for this version but 4.0.0 is newer than 3.2.3. There is a possibility that 3.2.3 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
[/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.22/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation tank.valvecontrol <> 0.0, <> on Real numbers is only allowed inside functions.
[/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.22/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation tank.valvecontrol <> 0.0, <> on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->Show additional information from the initialization process, in OMNotebook call setCommandLineOptions(\"-d=initialization\").
"

true
""
"/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.22/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank.fmu"


BouncingBall

a2ca7d4b7385b693c9b1193ce5c828c111dd73e1bd3a259b848807f9001d2388
e20ea3b4089f189c7e59e7cca5a57e51d3dfd58feaac4fa1a7399edcd0d69779
e390435d88845569b199af7775b47d8517f08521ea75837e8b3fb8be5b2a9f7c
d7c1628bbe241d61c27a8d6c747dd7b2bbb6b900df951b1570d526d369b6b942
c132f79cce417375ebd2749b4cbceaeb6fc80bfbb6c0fa9ebd945e665beb7e0b
bcad26a19d1d5eaab74bd16e854c21bf2f6b5546e6dd53cd50ead2d72e18fc1c
9f4527723fee5a5c9dbc3e1f066d56817f13095a695c9761c893a9e6c4f79077
ce18cb75e36111d7c8e358a0b71429ca1ca0303c2af443e8bb69a1cda841e3a4
da7ff98bce670484fe068e39c0116e7522588154514c47065be861b04da087b8
823744881ab66672d9be9406f4c99b00789822cd67bae0886d25456dd4d1d72f
ea307986651ddcd51b1ab81bd2ff0c3e846a89e34822d783aac745193cc44f74
5022e0ebdbdfd0f3906b9f694098a208c29102c6cab871cd08712a3f9827d19d
Warning: Requested package Complex of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package ModelicaServices of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package Modelica of version 4.0.0, but this package was already loaded with version 3.2.3. There are no conversion annotations for this version but 4.0.0 is newer than 3.2.3. There is a possibility that 3.2.3 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
Notification: The Makefile build for FMUs is deprecated and will be removed in a future version of OpenModelica. Use "--fmuCMakeBuild=true".


record SimulationResult
    resultFile = "/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.22/testsuite/special/FmuExportCrossCompile/BouncingBall_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'BouncingBall', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.161054849,
    timeBackend = 0.007029088,
    timeSimCode = 0.002067549,
    timeTemplates = 0.003981153,
    timeCompile = 0.7080642829999999,
    timeSimulation = 0.029983628,
    timeTotal = 0.912343655
end SimulationResult;
"Warning: Requested package Complex of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package ModelicaServices of version 3.2.3, but this package was already loaded with version 4.0.0. There are no conversion annotations and 3.2.3 is older than 4.0.0, so the libraries are probably incompatible.
Warning: Requested package Modelica of version 4.0.0, but this package was already loaded with version 3.2.3. There are no conversion annotations for this version but 4.0.0 is newer than 3.2.3. There is a possibility that 3.2.3 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
"

true
""
"/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.22/testsuite/special/FmuExportCrossCompile/BouncingBall.fmu"



unzip -q FmuExportCrossCompile.fmu -d FmuExportCrossCompile.fmutmp
make check-FmuExportCrossCompile-files
make[2]: Entering directory '/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.22/testsuite/special/FmuExportCrossCompile'
FmuExportCrossCompile.fmutmp/binaries/win32/FmuExportCrossCompile.dll: PE32 executable (DLL) (console) Intel 80386, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/win64/FmuExportCrossCompile.dll: PE32+ executable (DLL) (console) x86-64, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/darwin64/FmuExportCrossCompile.dylib: Mach-O 64-bit x86_64 dynamically linked shared library, flags:<NOUNDEFS|DYLDLINK|TWOLEVEL|NO_REEXPORTED_DYLIBS>
FmuExportCrossCompile.fmutmp/binaries/linux32/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, Intel 80386, version 1 (SYSV), dynamically linked, BuildID[sha1]=72b96274eac27844ac59eb76dc911c63ffc01dfb, not stripped
FmuExportCrossCompile.fmutmp/binaries/linux64/FmuExportCrossCompile.so: ELF 64-bit LSB shared object, x86-64, version 1 (SYSV), dynamically linked, BuildID[sha1]=b85630bace0903fca870d84f25b468d63c49856c, not stripped
FmuExportCrossCompile.fmutmp/binaries/arm-linux-gnueabihf/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, ARM, EABI5 version 1 (SYSV), dynamically linked, BuildID[sha1]=e4733777ffed40769c8c026b17161bed34653393, not stripped
make[2]: Leaving directory '/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.22/testsuite/special/FmuExportCrossCompile'
make[1]: Leaving directory '/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.22/testsuite/special/FmuExportCrossCompile'
make CMakeCrossCompile
make[1]: Entering directory '/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.22/testsuite/special/FmuExportCrossCompile'
HOME=/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.22/testsuite/special/FmuExportCrossCompile/../../../libraries/ ../../../build/bin/omc CMakeCrossCompile.mos

0
"/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.22/testsuite/special/FmuExportCrossCompile/CMakeCrossCompile"

{"x86_64-apple-darwin docker run multiarch/crossbuild","x86_64-linux-gnu docker run multiarch/crossbuild","i686-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13-i386","x86_64-w64-mingw32 docker run multiarch/crossbuild","i686-w64-mingw32 docker run multiarch/crossbuild"}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"/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.22/testsuite/special/FmuExportCrossCompile/CMakeCrossCompile/Modelica.Mechanics.MultiBody.Examples.Elementary.Pendulum.fmu"
""
unzip -qq CMakeCrossCompile/Modelica.Mechanics.MultiBody.Examples.Elementary.Pendulum.fmu -d CMakeCrossCompile/Pendulum_FMU/
make check-CMakeCrossCompile-files
make[2]: Entering directory '/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.22/testsuite/special/FmuExportCrossCompile'
CMakeCrossCompile/Pendulum_FMU/binaries/win32/Modelica_Mechanics_MultiBody_Examples_Elementary_Pendulum.dll: PE32 executable (DLL) (console) Intel 80386, for MS Windows
CMakeCrossCompile/Pendulum_FMU/binaries/win64/Modelica_Mechanics_MultiBody_Examples_Elementary_Pendulum.dll: PE32+ executable (DLL) (console) x86-64, for MS Windows
CMakeCrossCompile/Pendulum_FMU/binaries/darwin64/Modelica_Mechanics_MultiBody_Examples_Elementary_Pendulum.dylib: Mach-O 64-bit x86_64 dynamically linked shared library, flags:<NOUNDEFS|DYLDLINK|TWOLEVEL|NO_REEXPORTED_DYLIBS>
CMakeCrossCompile/Pendulum_FMU/binaries/linux32/Modelica_Mechanics_MultiBody_Examples_Elementary_Pendulum.so: ELF 32-bit LSB shared object, Intel 80386, version 1 (SYSV), dynamically linked, BuildID[sha1]=4a1ca2012a5df9307eef1e88515b0dbc9cdc7087, with debug_info, not stripped
CMakeCrossCompile/Pendulum_FMU/binaries/linux64/Modelica_Mechanics_MultiBody_Examples_Elementary_Pendulum.so: ELF 64-bit LSB shared object, x86-64, version 1 (SYSV), dynamically linked, BuildID[sha1]=e43904b3309949fdb0a21db2cf93171fe545e492, with debug_info, not stripped
make[2]: Leaving directory '/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.22/testsuite/special/FmuExportCrossCompile'
make[1]: Leaving directory '/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.22/testsuite/special/FmuExportCrossCompile'
make: Leaving directory '/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.22/testsuite/special/FmuExportCrossCompile'