Skip to content

Console Output

+ make -C testsuite/special/FmuExportCrossCompile/ test
make: Entering directory '/var/lib/jenkins2/ws/OpenModelica_maintenance_v1.18/testsuite/special/FmuExportCrossCompile'
rm -rf *.json *.xml *.html *.fmu* *.c *.makefile *.log *.o *.libs *.h *.mat *.csv Test_FMUs
HOME=/var/lib/jenkins2/ws/OpenModelica_maintenance_v1.18/testsuite/special/FmuExportCrossCompile/../../libraries-for-testing/ ../../../build/bin/omc fmuExportCrossCompile.mos

""

""

""

""

""
{"x86_64-apple-darwin15 docker run docker.openmodelica.org/osxcross-omsimulator:v2.0","arm-linux-gnueabihf docker run docker.openmodelica.org/armcross-omsimulator:v2.0","x86_64-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13","i686-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13-i386","x86_64-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0","i686-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0"}
FmuExportCrossCompile
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record SimulationResult
    resultFile = "/var/lib/jenkins2/ws/OpenModelica_maintenance_v1.18/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 0.45, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'FmuExportCrossCompile', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.133846026,
    timeBackend = 0.005520223,
    timeSimCode = 0.001732094,
    timeTemplates = 0.007428466000000001,
    timeCompile = 0.6889798199999999,
    timeSimulation = 0.034160319,
    timeTotal = 0.871864372
end SimulationResult;
""

"/var/lib/jenkins2/ws/OpenModelica_maintenance_v1.18/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile.fmu"


RoomHeating_OM_RH
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: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->Show additional information from the initialization process, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins2/ws/OpenModelica_maintenance_v1.18/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'RoomHeating_OM_RH', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "assert            | warning | The following assertion has been violated during initialization at time 0.000000
|                 | |       | fanspeed >= 0.01
assert            | warning | UTRC-FCU-002: FCU air damper should be opened at least 0.10.
LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.158967615,
    timeBackend = 0.016727077,
    timeSimCode = 0.003972101,
    timeTemplates = 0.007250469000000001,
    timeCompile = 0.80582529,
    timeSimulation = 0.088557938,
    timeTotal = 1.08146334
end SimulationResult;
"Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->Show additional information from the initialization process, in OMNotebook call setCommandLineOptions(\"-d=initialization\").
"

"/var/lib/jenkins2/ws/OpenModelica_maintenance_v1.18/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH.fmu"


WaterTank_Control

b705e6d3e9a0ec3c2fcfe40b610f5d6b7d3abeb1ed58a0b59b5aa5061fe6a287
9d66143338b9d6927c6ed467cde1065e511d2fd6598e457d9161b14f9530ad53
712d910c043d7c299cdc00fa521106e9b5edb8b708cdad4939ce05558f4480bc
acbc1991b65f6ad11ba208c5f77966d1ad15adef32d8d8f71d7d7c83fd01093a
0c7c5765d8b132df86c4bde1ec952ab0ef5b21f324072dd29de8e449796f74b6
55ba56fb288c047b630ca3433e73464f37de8753bac1b2b620ba4b190611583d
0be21e4257ec7b5876213662018691a6784fb6cc8003dadb016c65743bfa1bd6
9dd1378bfe007de25df1a44b558b8545984dd2a1443b9eef9798c33095af77bd
838e39864d2f4570994df9b17963f6ba1863664cd78aa0023e956f18eb37d76b
e71af746e98a5eeeaf66a156e917f77847c57fb95dd144678b88da83b500d5d2
a2555a75cf3216674cf4f4bc911cd2969745d2ed4f9ca324e60bd9f61eb623ec
33ec139de98bc09f007367fc8c663e68573e24f776ff5bba3875f29ef3bcdf19
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->Show additional information from the initialization process, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins2/ws/OpenModelica_maintenance_v1.18/testsuite/special/FmuExportCrossCompile/WaterTank_Control_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'WaterTank_Control', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.193920596,
    timeBackend = 0.005405346,
    timeSimCode = 0.002252858,
    timeTemplates = 0.007025595000000001,
    timeCompile = 0.6668528659999999,
    timeSimulation = 0.022633507,
    timeTotal = 0.898259485
end SimulationResult;
"Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->Show additional information from the initialization process, in OMNotebook call setCommandLineOptions(\"-d=initialization\").
"

"/var/lib/jenkins2/ws/OpenModelica_maintenance_v1.18/testsuite/special/FmuExportCrossCompile/WaterTank_Control.fmu"


WaterTank_TestSingleWaterTank

82a06584e0079fb9bbbefedf8240d375548ac168438ac304590f473f4011af5d
3e02a9d05bec11852ce0f86468ec969db5c2e8c5f0c00152a7c792a3f22a9759
1596c9adf3147fcf399a3c806b931e1487ca7f83faac565b4a2e84d56ecaf2eb
630e4b921418e2ca4a6d8ce9c50700346e1cb94c6d7690970078d32fc5dc62cc
2f13f9b23656d404970e5179e44e3814ba8d1e12f4fdc99a0bd1e9f910d52ae1
6db03c09808e1fbf72e610cc799ca5691742d5f902492383c8128d83cc28b08c
e803cb4fd54c3b379d8f9aaa56dead505be12c1f4375628d501019435859a281
4d536b48e7cd0e4a12035cbfa6f15b044109115c9564fd1346056d3c5e4290ca
5997fa1c68c87519edaf8e689c47f70bfd06aaca2f7114519ab24524bd003847
b84348678e91345f739d12bd69dbb116e8a7074a9de904058906314901352dba
5d9575ae327caa38916614f8be3967ede208488cca7da4fa521eae6da6359f3c
519e4f9c7a64773a29ed36015081eb023d3ec546bc25132c917d318e2d100704
[/var/lib/jenkins2/ws/OpenModelica_maintenance_v1.18/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation tank.valvecontrol <> 0.0, <> on Real numbers is only allowed inside functions.
[/var/lib/jenkins2/ws/OpenModelica_maintenance_v1.18/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation tank.valvecontrol <> 0.0, <> on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->Show additional information from the initialization process, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins2/ws/OpenModelica_maintenance_v1.18/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'WaterTank_TestSingleWaterTank', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.4461404920000001,
    timeBackend = 0.008910006,
    timeSimCode = 0.00228728,
    timeTemplates = 0.003457899,
    timeCompile = 0.667033189,
    timeSimulation = 0.037633446,
    timeTotal = 1.165632296
end SimulationResult;
"[/var/lib/jenkins2/ws/OpenModelica_maintenance_v1.18/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation tank.valvecontrol <> 0.0, <> on Real numbers is only allowed inside functions.
[/var/lib/jenkins2/ws/OpenModelica_maintenance_v1.18/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation tank.valvecontrol <> 0.0, <> on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->Show additional information from the initialization process, in OMNotebook call setCommandLineOptions(\"-d=initialization\").
"

"/var/lib/jenkins2/ws/OpenModelica_maintenance_v1.18/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank.fmu"


BouncingBall
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record SimulationResult
    resultFile = "/var/lib/jenkins2/ws/OpenModelica_maintenance_v1.18/testsuite/special/FmuExportCrossCompile/BouncingBall_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'BouncingBall', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.149985715,
    timeBackend = 0.008478085,
    timeSimCode = 0.002766825,
    timeTemplates = 0.010914306,
    timeCompile = 0.700309206,
    timeSimulation = 0.04087773099999992,
    timeTotal = 0.913479393
end SimulationResult;
""

"/var/lib/jenkins2/ws/OpenModelica_maintenance_v1.18/testsuite/special/FmuExportCrossCompile/BouncingBall.fmu"



unzip -q FmuExportCrossCompile.fmu -d FmuExportCrossCompile.fmutmp
make check-files
make[1]: Entering directory '/var/lib/jenkins2/ws/OpenModelica_maintenance_v1.18/testsuite/special/FmuExportCrossCompile'
FmuExportCrossCompile.fmutmp/binaries/win32/FmuExportCrossCompile.dll: PE32 executable (DLL) (console) Intel 80386, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/win64/FmuExportCrossCompile.dll: PE32+ executable (DLL) (console) x86-64, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/darwin64/FmuExportCrossCompile.dylib: Mach-O 64-bit x86_64 dynamically linked shared library, flags:<NOUNDEFS|DYLDLINK|TWOLEVEL|NO_REEXPORTED_DYLIBS>
FmuExportCrossCompile.fmutmp/binaries/linux32/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, Intel 80386, version 1 (SYSV), dynamically linked, BuildID[sha1]=382dde570f9139d546cc99e9f8d044153a447e28, not stripped
FmuExportCrossCompile.fmutmp/binaries/linux64/FmuExportCrossCompile.so: ELF 64-bit LSB shared object, x86-64, version 1 (SYSV), dynamically linked, BuildID[sha1]=0080a90e753c1e2b0940674612dd6c60fac7b8f2, not stripped
FmuExportCrossCompile.fmutmp/binaries/arm-linux-gnueabihf/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, ARM, EABI5 version 1 (SYSV), dynamically linked, BuildID[sha1]=fd3aad78921be086f276cfa6060b713bb9de18e7, not stripped
make[1]: Leaving directory '/var/lib/jenkins2/ws/OpenModelica_maintenance_v1.18/testsuite/special/FmuExportCrossCompile'
make: Leaving directory '/var/lib/jenkins2/ws/OpenModelica_maintenance_v1.18/testsuite/special/FmuExportCrossCompile'