Skip to content

Console Output

+ make -C testsuite/special/FmuExportCrossCompile/ test
make: Entering directory '/var/lib/jenkins2/ws/OpenModelica_maintenance_v1.18/testsuite/special/FmuExportCrossCompile'
rm -rf *.json *.xml *.html *.fmu* *.c *.makefile *.log *.o *.libs *.h *.mat *.csv Test_FMUs
HOME=/var/lib/jenkins2/ws/OpenModelica_maintenance_v1.18/testsuite/special/FmuExportCrossCompile/../../libraries-for-testing/ ../../../build/bin/omc fmuExportCrossCompile.mos

""

""

""

""

""
{"x86_64-apple-darwin15 docker run docker.openmodelica.org/osxcross-omsimulator:v2.0","arm-linux-gnueabihf docker run docker.openmodelica.org/armcross-omsimulator:v2.0","x86_64-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13","i686-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13-i386","x86_64-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0","i686-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0"}
FmuExportCrossCompile
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record SimulationResult
    resultFile = "/var/lib/jenkins2/ws/OpenModelica_maintenance_v1.18/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 0.45, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'FmuExportCrossCompile', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.121545841,
    timeBackend = 0.005259781000000001,
    timeSimCode = 0.001626167,
    timeTemplates = 0.010657477,
    timeCompile = 0.68662069,
    timeSimulation = 0.025917003,
    timeTotal = 0.851841958
end SimulationResult;
""

"/var/lib/jenkins2/ws/OpenModelica_maintenance_v1.18/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile.fmu"


RoomHeating_OM_RH
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: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->Show additional information from the initialization process, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins2/ws/OpenModelica_maintenance_v1.18/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'RoomHeating_OM_RH', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "assert            | warning | The following assertion has been violated during initialization at time 0.000000
|                 | |       | fanspeed >= 0.01
assert            | warning | UTRC-FCU-002: FCU air damper should be opened at least 0.10.
LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.342026738,
    timeBackend = 0.014175315,
    timeSimCode = 0.003145009,
    timeTemplates = 0.007271944000000001,
    timeCompile = 0.710906128,
    timeSimulation = 0.08055008500000001,
    timeTotal = 1.158243517
end SimulationResult;
"Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->Show additional information from the initialization process, in OMNotebook call setCommandLineOptions(\"-d=initialization\").
"

"/var/lib/jenkins2/ws/OpenModelica_maintenance_v1.18/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH.fmu"


WaterTank_Control

4e4e3a1e1b93f67fae632f335016021dc5dc9cefcb1eec4a7f3fc3e90c5d7a31
4af66727bba992ad7f997c4c39b124dde352a7ff58ea7277840c4e145e11fb4b
ce2a77f29e339ab43c050efc4288f6cc5636984cdac725fa75bbed9b2e2ab56b
940cf762b403693a2b770ea6da8bfb406a158f0a86e71ef37794d1b191d45144
3c66f5f446bf200972a64e0bee96419d10d95ffc9b6b240bd83fe724fd017809
354af98652043c4585d714b5265e6b30334476f2d616562b3a81e878838a96f5
d476469903a1ea8e941143c07239b7dd0e43984484a7f3c053d76b662a6d5043
7ad0ff8f991ba0afa8612b8a0c940c6bb09bc9db60c604d2b67ead074a939d0f
86290460f2b6aa6e3ead110231f1feb7fe0d5bd875f13e33305576429193c87d
54eba30a3a525fa0b9257fd60cbd4df05fa256db7bc55ae86dbf5cfd59770601
c6b9381c750d7766581c1b4319f9649e4ff6f3442462cea5ee5848ebdb4efa21
ffe75d94a0739558d576e1d4e0604b0b9f72e510a2fcff2b5296c5b8c00a42a1
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->Show additional information from the initialization process, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins2/ws/OpenModelica_maintenance_v1.18/testsuite/special/FmuExportCrossCompile/WaterTank_Control_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'WaterTank_Control', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.121327439,
    timeBackend = 0.003669441,
    timeSimCode = 0.001254741,
    timeTemplates = 0.008797085000000001,
    timeCompile = 0.6570901880000001,
    timeSimulation = 0.029641511,
    timeTotal = 0.8219485740000001
end SimulationResult;
"Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->Show additional information from the initialization process, in OMNotebook call setCommandLineOptions(\"-d=initialization\").
"

"/var/lib/jenkins2/ws/OpenModelica_maintenance_v1.18/testsuite/special/FmuExportCrossCompile/WaterTank_Control.fmu"


WaterTank_TestSingleWaterTank
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[/var/lib/jenkins2/ws/OpenModelica_maintenance_v1.18/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation tank.valvecontrol <> 0.0, <> on Real numbers is only allowed inside functions.
[/var/lib/jenkins2/ws/OpenModelica_maintenance_v1.18/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation tank.valvecontrol <> 0.0, <> on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->Show additional information from the initialization process, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins2/ws/OpenModelica_maintenance_v1.18/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'WaterTank_TestSingleWaterTank', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.120869608,
    timeBackend = 0.010012367,
    timeSimCode = 0.002639856,
    timeTemplates = 0.007130819,
    timeCompile = 0.7618085480000001,
    timeSimulation = 0.06179171499999991,
    timeTotal = 0.964374558
end SimulationResult;
"[/var/lib/jenkins2/ws/OpenModelica_maintenance_v1.18/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation tank.valvecontrol <> 0.0, <> on Real numbers is only allowed inside functions.
[/var/lib/jenkins2/ws/OpenModelica_maintenance_v1.18/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation tank.valvecontrol <> 0.0, <> on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->Show additional information from the initialization process, in OMNotebook call setCommandLineOptions(\"-d=initialization\").
"

"/var/lib/jenkins2/ws/OpenModelica_maintenance_v1.18/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank.fmu"


BouncingBall

1b81bc10599e93716138793cc261ae4538d7f40ca578c6642ccc195ef4b02fa3
e240f0cae57e5d2f392d08115525bc601eff80a0c8bed5f35091f68b91e2f277
63ae0121b3bb42b0f5e6ecd8c6ce09ff57502dc04a6b080210433808ce2c5a5f
02c29115a46053cea4d250d428ad7346e1d8c1d8d71a5cd3eb811fd24aed47ea
697b6572565c6d2579db07cb201b21acf0f37e01b77245e9e69543ea68f25308
64ea954c9dff10b01231d6f0d5c243a2661714971d84207a948672b4f37a5c3a
cac2db7e3d26ee0c749cf52a7f326697b9f7ce7796de31528c52436046c6a616
00f3cc80fa87c1477528c8d06af01188a302a224f7f10a11bd32e8bfe58bb636
2c1231c6aacb2404b18730ab63c6dd9705f1bcd83481e19ab4edadc14b6b867c
8df332ca7bc360978ad9ab3fbc7944bd3e9004075a0efd00a842a7e827d7c0d6
f23b29203a9f321250f3cf87a9ad27d0233d62a81efe6e425e2cbfee31ff238d
020225f106e2a7c4e7b01c45d921a408e0786d0fa4a851b26b5be2da4593cdbd


record SimulationResult
    resultFile = "/var/lib/jenkins2/ws/OpenModelica_maintenance_v1.18/testsuite/special/FmuExportCrossCompile/BouncingBall_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'BouncingBall', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.315053344,
    timeBackend = 0.005603478,
    timeSimCode = 0.00209096,
    timeTemplates = 0.008588885000000001,
    timeCompile = 0.704534058,
    timeSimulation = 0.03469448,
    timeTotal = 1.070721244
end SimulationResult;
""

"/var/lib/jenkins2/ws/OpenModelica_maintenance_v1.18/testsuite/special/FmuExportCrossCompile/BouncingBall.fmu"



unzip -q FmuExportCrossCompile.fmu -d FmuExportCrossCompile.fmutmp
make check-files
make[1]: Entering directory '/var/lib/jenkins2/ws/OpenModelica_maintenance_v1.18/testsuite/special/FmuExportCrossCompile'
FmuExportCrossCompile.fmutmp/binaries/win32/FmuExportCrossCompile.dll: PE32 executable (DLL) (console) Intel 80386, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/win64/FmuExportCrossCompile.dll: PE32+ executable (DLL) (console) x86-64, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/darwin64/FmuExportCrossCompile.dylib: Mach-O 64-bit x86_64 dynamically linked shared library, flags:<NOUNDEFS|DYLDLINK|TWOLEVEL|NO_REEXPORTED_DYLIBS>
FmuExportCrossCompile.fmutmp/binaries/linux32/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, Intel 80386, version 1 (SYSV), dynamically linked, BuildID[sha1]=cab979361e908eeaf8c900992ef907601e538bfa, not stripped
FmuExportCrossCompile.fmutmp/binaries/linux64/FmuExportCrossCompile.so: ELF 64-bit LSB shared object, x86-64, version 1 (SYSV), dynamically linked, BuildID[sha1]=49fae0d1db60863263e26feebac24f897a85cabc, not stripped
FmuExportCrossCompile.fmutmp/binaries/arm-linux-gnueabihf/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, ARM, EABI5 version 1 (SYSV), dynamically linked, BuildID[sha1]=7efe5f25d6ce9fd62269956faa3515d33d362cd0, not stripped
make[1]: Leaving directory '/var/lib/jenkins2/ws/OpenModelica_maintenance_v1.18/testsuite/special/FmuExportCrossCompile'
make: Leaving directory '/var/lib/jenkins2/ws/OpenModelica_maintenance_v1.18/testsuite/special/FmuExportCrossCompile'