Skip to content

Console Output

+ make -C testsuite/special/FmuExportCrossCompile/ test
make: Entering directory '/var/lib/jenkins2/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile'
rm -rf *.json *.xml *.html *.fmu* *.c *.makefile *.log *.o *.libs *.h *.mat *.csv Test_FMUs
HOME=/var/lib/jenkins2/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/../../libraries-for-testing/ ../../../build/bin/omc fmuExportCrossCompile.mos

""

""

""

""

""
{"x86_64-apple-darwin15 docker run docker.openmodelica.org/osxcross-omsimulator:v2.0","arm-linux-gnueabihf docker run docker.openmodelica.org/armcross-omsimulator:v2.0","x86_64-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13","i686-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13-i386","x86_64-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0","i686-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0"}
FmuExportCrossCompile
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record SimulationResult
    resultFile = "/var/lib/jenkins2/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 0.45, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'FmuExportCrossCompile', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.118835043,
    timeBackend = 0.005003716,
    timeSimCode = 0.001460214,
    timeTemplates = 0.005577608,
    timeCompile = 0.867518263,
    timeSimulation = 0.037912029,
    timeTotal = 1.082504629
end SimulationResult;
""

"/var/lib/jenkins2/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile.fmu"


RoomHeating_OM_RH
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: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins2/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'RoomHeating_OM_RH', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "assert            | warning | The following assertion has been violated during initialization at time 0.000000
|                 | |       | fanspeed >= 0.01
assert            | warning | UTRC-FCU-002: FCU air damper should be opened at least 0.10.
LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.3551903319999999,
    timeBackend = 0.012736535,
    timeSimCode = 0.002698607,
    timeTemplates = 0.004798008,
    timeCompile = 0.678373817,
    timeSimulation = 0.09690714,
    timeTotal = 1.150877018
end SimulationResult;
"Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions(\"-d=initialization\").
"

"/var/lib/jenkins2/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH.fmu"


WaterTank_Control

1f530f00b8d6e59bfbd213a02f89c4abf760108459f07c4db79312dd965c1f89
bdd33196edb345b2303deb6562ea98f7c345b01e126f60a5098e559936880867
84b05a9e21370e0da62ecd021f7a090788f88309a865ecc22cab805989b4f0db
e6ffe053605c13ee6e40531b5c6353cb1f986b921d3c7d566176b14fde3197d6
88ebc58466f5d0334fb109a7dc398bac7f1b7faee797e7d8568b36e210e3632e
cf6211f573f2e0877accee04a77586dc2b1811626420c0724968a74288ba9901
0202c44d5975ce215350f7e7df89f22e8b02f4e7497cbe97fcdedb70f0a26c45
d6a58963e87f8d38959640d8282cfd1a634ec2e399039342a9157e4d0cdfca36
123697900d06c435abdc6deebaa5535da3125dbb3df295b4a0ca06679fc75342
06dc38959022cb585f7bcd8666f94e0c07333e6e50d300e8d25eebee50f489f7
5769ec72a4db2e37e1efec4f55af63b9dda543071853a4009c9d2bfd0d8917ce
d34141d9d8910520e146b1d798f51b90f0488b6339e80e68bbee07ea9f77c1c5
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins2/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/WaterTank_Control_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'WaterTank_Control', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.102148854,
    timeBackend = 0.003076581,
    timeSimCode = 0.0008801480000000001,
    timeTemplates = 0.006257972000000001,
    timeCompile = 0.605853312,
    timeSimulation = 0.042192434,
    timeTotal = 0.760536094
end SimulationResult;
"Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions(\"-d=initialization\").
"

"/var/lib/jenkins2/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/WaterTank_Control.fmu"


WaterTank_TestSingleWaterTank

80d5fa7c3a8783eddd35f420e29b77b53b4d4839dd80ca2cd00939664233c44b
4d73386e60e3f4bbdd737f5b3549fdda94757bed3424e3f0fe6615edb5f1a83b
34891297ee37b55081b73db51eb88b9a5e0d3b9ae517625f1afb792918617748
fc0346f3de19fdb0be3a4eb72d825931a477d7c2a31c0322b193b85f56bcec88
e60d17f4743e69d47f87bdb5da5ef4ea3e4f4a0c49ab46c98c1c5addcc53d541
7f1e6c5ec0ed30815820a087e5289b48191242428cf642f7d04548f66de808a6
77ef3ae04ae5888ed65c3f37ea42be75e2748e0f7886d4a2de85f24ce820b70b
9dbb67a72ceedcbaeae6670b49419e609f4236b5954e3516a019816dd1c31d7b
0eae3b6829459af9e60da6f2bbd2e157dadfa74d3c7f9e842e0c6e0e8c76b48a
f76f6b7ebcfa38e224e81fd12b8fa16e5d0b5570d4dd00a0c1b1a2ab79aea398
2c5ae1b9b3c5bd5c58875c08e7c35060326a3789f8b42b7887c2b73974069510
7657b7cc4c30f254d3229ba88ce1e54347da2d870b08a92861078f700e0a188b
[/var/lib/jenkins2/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation tank.valvecontrol <> 0.0, <> on Real numbers is only allowed inside functions.
[/var/lib/jenkins2/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation tank.valvecontrol <> 0.0, <> on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins2/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'WaterTank_TestSingleWaterTank', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.099657201,
    timeBackend = 0.008026792000000001,
    timeSimCode = 0.002019883,
    timeTemplates = 0.003611012,
    timeCompile = 0.6402811939999999,
    timeSimulation = 0.042718838,
    timeTotal = 0.7964571
end SimulationResult;
"[/var/lib/jenkins2/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation tank.valvecontrol <> 0.0, <> on Real numbers is only allowed inside functions.
[/var/lib/jenkins2/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation tank.valvecontrol <> 0.0, <> on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions(\"-d=initialization\").
"

"/var/lib/jenkins2/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank.fmu"


BouncingBall
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record SimulationResult
    resultFile = "/var/lib/jenkins2/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/BouncingBall_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'BouncingBall', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.116132787,
    timeBackend = 0.005814522000000001,
    timeSimCode = 0.00177363,
    timeTemplates = 0.006654427,
    timeCompile = 0.680465361,
    timeSimulation = 0.047297742,
    timeTotal = 0.858284493
end SimulationResult;
""

"/var/lib/jenkins2/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/BouncingBall.fmu"



unzip -q FmuExportCrossCompile.fmu -d FmuExportCrossCompile.fmutmp
make check-files
make[1]: Entering directory '/var/lib/jenkins2/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile'
FmuExportCrossCompile.fmutmp/binaries/win32/FmuExportCrossCompile.dll: PE32 executable (DLL) (console) Intel 80386, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/win64/FmuExportCrossCompile.dll: PE32+ executable (DLL) (console) x86-64, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/darwin64/FmuExportCrossCompile.dylib: Mach-O 64-bit x86_64 dynamically linked shared library, flags:<NOUNDEFS|DYLDLINK|TWOLEVEL|NO_REEXPORTED_DYLIBS>
FmuExportCrossCompile.fmutmp/binaries/linux32/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, Intel 80386, version 1 (SYSV), dynamically linked, BuildID[sha1]=5bb19b17046f2958dddab6baf2799824e55fc3c5, not stripped
FmuExportCrossCompile.fmutmp/binaries/linux64/FmuExportCrossCompile.so: ELF 64-bit LSB shared object, x86-64, version 1 (SYSV), dynamically linked, BuildID[sha1]=c49c0fd9e34e01cd6f3a66cb61345681c1ff26b7, not stripped
FmuExportCrossCompile.fmutmp/binaries/arm-linux-gnueabihf/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, ARM, EABI5 version 1 (SYSV), dynamically linked, BuildID[sha1]=f4d685177a028120ae66280b71c9b613c2cccc0d, not stripped
make[1]: Leaving directory '/var/lib/jenkins2/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile'
make: Leaving directory '/var/lib/jenkins2/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile'