Skip to content

Console Output

+ make -C testsuite/special/FmuExportCrossCompile/ test
make: Entering directory '/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile'
rm -rf *.json *.xml *.html *.fmu* *.c *.makefile *.log *.o *.libs *.h *.mat *.csv Test_FMUs
HOME=/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/../../libraries-for-testing/ ../../../build/bin/omc fmuExportCrossCompile.mos

""

""

""

""

""
{"x86_64-apple-darwin15 docker run docker.openmodelica.org/osxcross-omsimulator:v2.0","arm-linux-gnueabihf docker run docker.openmodelica.org/armcross-omsimulator:v2.0","x86_64-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13","i686-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13-i386","x86_64-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0","i686-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0"}
FmuExportCrossCompile

3880d23a4fbc8a738507a99b74a7b21989b99479a0dd130e06d291321d17c137
a9d716ff8962fb29f3c6ead86ecc1729d7480d9291c2c2ce014afae97f632a02
3f64b64b7fd55021fcc2b373e7c3dc9274887197c48efec086745cbf76bf0b66
bb913a58fe950fc4b3c8f8b61e99a8bd8745ef989e1a34207ac86a5e1de5b34c
a24500a42c6fc40ab53ce580b2041ce298254b72bf6c283dbdb419688b2d3a19
f8943082d51c5ae6e57617fd26bad8881bedc2f2450608f4eeeca751b84c1003
4d39b1336e729c9c3a40f52b93a3dacca8595826e2d8580b31024833f52a241f
d1cfe7d17a12d6d6fc712b9e3a03241573a8341d57564975288c1cd8a259c2ce
25b4cfe4a3015b4c5141d1a03330dc056237bd614a1d5e7add25c702cb96c7a2
aa8bcafd40a96d532a7d4309772b6006b2ae447023df3941cb5d2af4656109dc
e8e6b162ce09f9d3aa73a2fc8097eca083249295b4db030658df8b417beb8136
ebc9d50cd8c3a31968404e15baa197e172fbb61d16f9d18a93d8d52ed550e528


record SimulationResult
    resultFile = "/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 0.45, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'FmuExportCrossCompile', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.094923701,
    timeBackend = 0.002660517,
    timeSimCode = 0.0007369960000000001,
    timeTemplates = 0.007673577000000001,
    timeCompile = 0.5353805770000001,
    timeSimulation = 0.030563693,
    timeTotal = 0.672106266
end SimulationResult;
""

"/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile.fmu"


RoomHeating_OM_RH
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: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'RoomHeating_OM_RH', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "assert            | warning | The following assertion has been violated during initialization at time 0.000000
|                 | |       | fanspeed >= 0.01
assert            | warning | UTRC-FCU-002: FCU air damper should be opened at least 0.10.
LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.25626337,
    timeBackend = 0.007485351,
    timeSimCode = 0.001687294,
    timeTemplates = 0.004947707,
    timeCompile = 0.5651465,
    timeSimulation = 0.06886887300000001,
    timeTotal = 0.904506528
end SimulationResult;
"Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions(\"-d=initialization\").
"

"/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH.fmu"


WaterTank_Control

c4322491400de400a4b8f53f00f0fd4353910255c5a3107b6fab5038afa9c1fa
b2043bd7dd504da3e17d3bacde98f06894b867f92a5099ab5188ac62c04bf356
cd278c887c09874d53b3b421faa28d6cf7f4eb4eda87c9f1c4f6dc62cadeeee4
6fca389089d8ddf56fcfea59f70ab1beadb24b23ee1ea1e86a865321735ad941
90662830285e41d7bf32114a44190e67b6e38724fcea8af676aed7aa83d48ace
e91c2d14b7c19ea8b32d78f4ec7b5d2aa34565813fb783fd64fe0ddda7bd762f
c864d8a9211147214f082a280a0154d60142cfd6ac45430b3041fb465787fc3e
e1669c6c1dbe2499c0c0213b543a3b68cd0c0fcfb996146026b36ff409dd82eb
c6589bab594875f3993c6625e49e170bd04968e91b56a253a31d0ccaa163687a
354706c2efbad9aac2502dfe573e20e6041fe26472475eb7f20ddfd07cc7b38a
fa5ed8455c94787c7a00c1b16855481ae67c6ec79abe65b91c25e77e8af8495c
385dd843867ea33e47d58b050f31e33aa617463dd529c6fa116ef05313429124
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/WaterTank_Control_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'WaterTank_Control', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.136824717,
    timeBackend = 0.002628607,
    timeSimCode = 0.0007920500000000001,
    timeTemplates = 0.007578758000000001,
    timeCompile = 0.583241137,
    timeSimulation = 0.021946158,
    timeTotal = 0.75313445
end SimulationResult;
"Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions(\"-d=initialization\").
"

"/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/WaterTank_Control.fmu"


WaterTank_TestSingleWaterTank
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[/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation tank.valvecontrol <> 0.0, <> on Real numbers is only allowed inside functions.
[/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation tank.valvecontrol <> 0.0, <> on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'WaterTank_TestSingleWaterTank', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.107778186,
    timeBackend = 0.004937488,
    timeSimCode = 0.001287097,
    timeTemplates = 0.00441604,
    timeCompile = 0.5244955689999999,
    timeSimulation = 0.04823594,
    timeTotal = 0.691270439
end SimulationResult;
"[/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation tank.valvecontrol <> 0.0, <> on Real numbers is only allowed inside functions.
[/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation tank.valvecontrol <> 0.0, <> on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions(\"-d=initialization\").
"

"/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank.fmu"


BouncingBall
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record SimulationResult
    resultFile = "/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/BouncingBall_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'BouncingBall', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.112657373,
    timeBackend = 0.003276273,
    timeSimCode = 0.001031012,
    timeTemplates = 0.007414006000000001,
    timeCompile = 0.6970361940000001,
    timeSimulation = 0.036041244,
    timeTotal = 0.857595125
end SimulationResult;
""

"/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/BouncingBall.fmu"



unzip -q FmuExportCrossCompile.fmu -d FmuExportCrossCompile.fmutmp
make check-files
make[1]: Entering directory '/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile'
FmuExportCrossCompile.fmutmp/binaries/win32/FmuExportCrossCompile.dll: PE32 executable (DLL) (console) Intel 80386, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/win64/FmuExportCrossCompile.dll: PE32+ executable (DLL) (console) x86-64, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/darwin64/FmuExportCrossCompile.dylib: Mach-O 64-bit x86_64 dynamically linked shared library, flags:<NOUNDEFS|DYLDLINK|TWOLEVEL|NO_REEXPORTED_DYLIBS>
FmuExportCrossCompile.fmutmp/binaries/linux32/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, Intel 80386, version 1 (SYSV), dynamically linked, BuildID[sha1]=252ea088a545d963e1745047b96627ecb1a7223d, not stripped
FmuExportCrossCompile.fmutmp/binaries/linux64/FmuExportCrossCompile.so: ELF 64-bit LSB shared object, x86-64, version 1 (SYSV), dynamically linked, BuildID[sha1]=cbbc648037d2fe74fa53a356f0aeae9adbaa68c9, not stripped
FmuExportCrossCompile.fmutmp/binaries/arm-linux-gnueabihf/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, ARM, EABI5 version 1 (SYSV), dynamically linked, BuildID[sha1]=c07a95b5d7a83327b5aa344bb0b9be24d8d120d4, not stripped
make[1]: Leaving directory '/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile'
make: Leaving directory '/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile'