Skip to content

Console Output

+ make -C testsuite/special/FmuExportCrossCompile/ test
make: Entering directory '/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile'
rm -rf *.json *.xml *.html *.fmu* *.c *.makefile *.log *.o *.libs *.h *.mat *.csv Test_FMUs
HOME=/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/../../libraries-for-testing/ ../../../build/bin/omc fmuExportCrossCompile.mos

""

""

""

""

""
{"x86_64-apple-darwin15 docker run docker.openmodelica.org/osxcross-omsimulator:v2.0","arm-linux-gnueabihf docker run docker.openmodelica.org/armcross-omsimulator:v2.0","x86_64-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13","i686-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13-i386","x86_64-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0","i686-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0"}
FmuExportCrossCompile
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record SimulationResult
    resultFile = "/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 0.45, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'FmuExportCrossCompile', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.08429215300000001,
    timeBackend = 0.002714289,
    timeSimCode = 0.0007801770000000001,
    timeTemplates = 0.009409384,
    timeCompile = 0.53051237,
    timeSimulation = 0.031310798,
    timeTotal = 0.65919901
end SimulationResult;
""

"/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile.fmu"


RoomHeating_OM_RH
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: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'RoomHeating_OM_RH', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "assert            | warning | The following assertion has been violated during initialization at time 0.000000
|                 | |       | fanspeed >= 0.01
assert            | warning | UTRC-FCU-002: FCU air damper should be opened at least 0.10.
LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.303737748,
    timeBackend = 0.007506551,
    timeSimCode = 0.001629465,
    timeTemplates = 0.006670729,
    timeCompile = 0.6380624749999999,
    timeSimulation = 0.05725964400000001,
    timeTotal = 1.014979597
end SimulationResult;
"Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions(\"-d=initialization\").
"

"/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH.fmu"


WaterTank_Control
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: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/WaterTank_Control_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'WaterTank_Control', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.134094238,
    timeBackend = 0.002388251,
    timeSimCode = 0.0007961870000000001,
    timeTemplates = 0.006740090000000001,
    timeCompile = 0.5724107620000001,
    timeSimulation = 0.02878821199999992,
    timeTotal = 0.7453842980000001
end SimulationResult;
"Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions(\"-d=initialization\").
"

"/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/WaterTank_Control.fmu"


WaterTank_TestSingleWaterTank
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[/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation tank.valvecontrol <> 0.0, <> on Real numbers is only allowed inside functions.
[/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation tank.valvecontrol <> 0.0, <> on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'WaterTank_TestSingleWaterTank', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.09973792400000001,
    timeBackend = 0.004904946,
    timeSimCode = 0.001249626,
    timeTemplates = 0.018531645,
    timeCompile = 0.5630060170000001,
    timeSimulation = 0.045172632,
    timeTotal = 0.7327063150000001
end SimulationResult;
"[/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation tank.valvecontrol <> 0.0, <> on Real numbers is only allowed inside functions.
[/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation tank.valvecontrol <> 0.0, <> on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions(\"-d=initialization\").
"

"/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank.fmu"


BouncingBall
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record SimulationResult
    resultFile = "/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/BouncingBall_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'BouncingBall', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.330825682,
    timeBackend = 0.004807091,
    timeSimCode = 0.001403868,
    timeTemplates = 0.005431764,
    timeCompile = 0.555394918,
    timeSimulation = 0.035436088,
    timeTotal = 0.9334141659999999
end SimulationResult;
""

"/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/BouncingBall.fmu"



unzip -q FmuExportCrossCompile.fmu -d FmuExportCrossCompile.fmutmp
make check-files
make[1]: Entering directory '/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile'
FmuExportCrossCompile.fmutmp/binaries/win32/FmuExportCrossCompile.dll: PE32 executable (DLL) (console) Intel 80386, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/win64/FmuExportCrossCompile.dll: PE32+ executable (DLL) (console) x86-64, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/darwin64/FmuExportCrossCompile.dylib: Mach-O 64-bit x86_64 dynamically linked shared library, flags:<NOUNDEFS|DYLDLINK|TWOLEVEL|NO_REEXPORTED_DYLIBS>
FmuExportCrossCompile.fmutmp/binaries/linux32/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, Intel 80386, version 1 (SYSV), dynamically linked, BuildID[sha1]=5120d36e0b5c94fe7b6bfd8fe6f334648fd4a076, not stripped
FmuExportCrossCompile.fmutmp/binaries/linux64/FmuExportCrossCompile.so: ELF 64-bit LSB shared object, x86-64, version 1 (SYSV), dynamically linked, BuildID[sha1]=a85491a4c2e8156f087740c2ea9b8784c97a0b99, not stripped
FmuExportCrossCompile.fmutmp/binaries/arm-linux-gnueabihf/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, ARM, EABI5 version 1 (SYSV), dynamically linked, BuildID[sha1]=0e3b4577972289f2d7f9e2fd7cb93afea6eadb2c, not stripped
make[1]: Leaving directory '/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile'
make: Leaving directory '/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile'