Skip to content

Console Output

+ make -C testsuite/special/FmuExportCrossCompile/ test
make: Entering directory '/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile'
rm -rf *.json *.xml *.html *.fmu* *.c *.makefile *.log *.o *.libs *.h *.mat *.csv Test_FMUs
HOME=/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/../../libraries-for-testing/ ../../../build/bin/omc fmuExportCrossCompile.mos

""

""

""

""

""
{"x86_64-apple-darwin15 docker run docker.openmodelica.org/osxcross-omsimulator:v2.0","arm-linux-gnueabihf docker run docker.openmodelica.org/armcross-omsimulator:v2.0","x86_64-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13","i686-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13-i386","x86_64-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0","i686-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0"}
FmuExportCrossCompile

c269dd9b9735dffd7d4932a90769913c24f682959093887166857239e3c090d9
cbdeb750c8d2b2a199066ff784ed9ce71b1965a472780f2222262a7e485ed02d
780bc7cf8d2258bacd76aab207196eccc13343287aced29382b990013b609bd4
fa37a3059cb31a65b03c0fd753fb482bac9a3c658fbdb5150d39c97c0a0ed5d9
116311d594a101cfd4caa425a4771a4b760d92358286a5122daef4615dc11367
3c15503f571b113dee123a862d8997649cec0b4e8e5ab448c62f5e6a4bdea383
62cae40a2d49febece4ce3e2e54a6a91872a6dba6ca658a4be0d6f4ca3d89a66
f0e5f44cbe252788c956cf078ef7041389b9687ea70eddc3a7c128396e3ea86e
e7a9bb4b55a712051ddec07898ad99fd17fe9c5dbf09cf20859aeb1faac715da
c0e2477c05c34eaf10aba18efbe09210364fea94864e59eae101ca8daac75ab8
8e5b33171282015fb0aa94713e0aa4b2c27e29a746330def6a2eb1070a00fad8
436024920adbe81b499725c1028ccc348e125d13ef569193e5b9dc584cce53de


record SimulationResult
    resultFile = "/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 0.45, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'FmuExportCrossCompile', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.07417059000000001,
    timeBackend = 0.002326274,
    timeSimCode = 0.000636505,
    timeTemplates = 0.003291622,
    timeCompile = 0.418362587,
    timeSimulation = 0.02784918399999992,
    timeTotal = 0.526774023
end SimulationResult;
""

"/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile.fmu"


RoomHeating_OM_RH
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: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'RoomHeating_OM_RH', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "assert            | warning | The following assertion has been violated during initialization at time 0.000000
|                 | |       | fanspeed >= 0.01
assert            | warning | UTRC-FCU-002: FCU air damper should be opened at least 0.10.
LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.21973822,
    timeBackend = 0.006232229000000001,
    timeSimCode = 0.001348313,
    timeTemplates = 0.004198619000000001,
    timeCompile = 0.412245927,
    timeSimulation = 0.041103157,
    timeTotal = 0.684958098
end SimulationResult;
"Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions(\"-d=initialization\").
"

"/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH.fmu"


WaterTank_Control
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: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/WaterTank_Control_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'WaterTank_Control', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.072814163,
    timeBackend = 0.001466095,
    timeSimCode = 0.000446976,
    timeTemplates = 0.003130116,
    timeCompile = 0.385923673,
    timeSimulation = 0.022218334,
    timeTotal = 0.486085291
end SimulationResult;
"Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions(\"-d=initialization\").
"

"/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/WaterTank_Control.fmu"


WaterTank_TestSingleWaterTank
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[/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation tank.valvecontrol <> 0.0, <> on Real numbers is only allowed inside functions.
[/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation tank.valvecontrol <> 0.0, <> on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'WaterTank_TestSingleWaterTank', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.073638303,
    timeBackend = 0.004027134,
    timeSimCode = 0.001035881,
    timeTemplates = 0.00376597,
    timeCompile = 0.4409701779999999,
    timeSimulation = 0.032248734,
    timeTotal = 0.5557782339999999
end SimulationResult;
"[/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation tank.valvecontrol <> 0.0, <> on Real numbers is only allowed inside functions.
[/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation tank.valvecontrol <> 0.0, <> on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions(\"-d=initialization\").
"

"/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank.fmu"


BouncingBall

ab88e48c769650f075b982c09d3adf7b92c78d409fa1e5092a73acf0d3115d7a
3e6ab65ca13f5a64b83fd06c9c9322007d9617ea9903c6c515885bd274433aab
9dd01ea46021b92f5244cfdb42ff029a3a92ad654caa80359f0c488f9e64d1f9
ca383b0ef0c80036539f3a93371a334934caf112cff8875977b9cf8053cdc544
0b1489fafeb5037c11e5c6363adf696236b7011cd60d09296d65483fdafb3216
4a0252cc977824d3212b5d8f6164c15ee398c0e30055fbfd8e0ebd15fef91178
25a75c052d1d5ad02c9baed1b4907b495cd069eb472457c9783984542fa73ebb
d543668401179df3779df38133a0fb0b1f69065561b50e75a76af0ee65d9722b
28852562e7383756a2dec51137f978770387e0bf8d156de4db1d94971a012aec
8901d7f131701e1c218ec698cede197e6478bd850494918d52fed6e9e5466275
a155e50e127baefb3387561985d31a01b35dd1faae4b6667fce2d81ce52373f5
fb22abdd0bfd704d2e60528809e50a0cf82025368fec9faad67a1c5cd72350a0


record SimulationResult
    resultFile = "/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/BouncingBall_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'BouncingBall', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.07813153999999989,
    timeBackend = 0.002677289,
    timeSimCode = 0.0007955060000000001,
    timeTemplates = 0.003340775,
    timeCompile = 0.44199083,
    timeSimulation = 0.026233816,
    timeTotal = 0.553266949
end SimulationResult;
""

"/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/BouncingBall.fmu"



unzip -q FmuExportCrossCompile.fmu -d FmuExportCrossCompile.fmutmp
make check-files
make[1]: Entering directory '/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile'
FmuExportCrossCompile.fmutmp/binaries/win32/FmuExportCrossCompile.dll: PE32 executable (DLL) (console) Intel 80386, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/win64/FmuExportCrossCompile.dll: PE32+ executable (DLL) (console) x86-64, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/darwin64/FmuExportCrossCompile.dylib: Mach-O 64-bit x86_64 dynamically linked shared library, flags:<NOUNDEFS|DYLDLINK|TWOLEVEL|NO_REEXPORTED_DYLIBS>
FmuExportCrossCompile.fmutmp/binaries/linux32/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, Intel 80386, version 1 (SYSV), dynamically linked, BuildID[sha1]=4a55fdd8eb8836f706efad0eae13f596200f6b81, not stripped
FmuExportCrossCompile.fmutmp/binaries/linux64/FmuExportCrossCompile.so: ELF 64-bit LSB shared object, x86-64, version 1 (SYSV), dynamically linked, BuildID[sha1]=0549d456b042d4a9de2594a3944327451b2b7361, not stripped
FmuExportCrossCompile.fmutmp/binaries/arm-linux-gnueabihf/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, ARM, EABI5 version 1 (SYSV), dynamically linked, BuildID[sha1]=bea82a35049a8a427a9875a0539d9bf91d2d9827, not stripped
make[1]: Leaving directory '/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile'
make: Leaving directory '/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile'