Skip to content

Console Output

+ make -C testsuite/special/FmuExportCrossCompile/ test
make: Entering directory '/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile'
rm -rf *.json *.xml *.html *.fmu* *.c *.makefile *.log *.o *.libs *.h *.mat *.csv Test_FMUs
HOME=/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/../../libraries-for-testing/ ../../../build/bin/omc fmuExportCrossCompile.mos

""

""

""

""

""
{"x86_64-apple-darwin15 docker run docker.openmodelica.org/osxcross-omsimulator:v2.0","arm-linux-gnueabihf docker run docker.openmodelica.org/armcross-omsimulator:v2.0","x86_64-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13","i686-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13-i386","x86_64-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0","i686-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0"}
FmuExportCrossCompile
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record SimulationResult
    resultFile = "/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 0.45, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'FmuExportCrossCompile', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.195700859,
    timeBackend = 0.007185659,
    timeSimCode = 0.002328358,
    timeTemplates = 0.015561048,
    timeCompile = 0.691666895,
    timeSimulation = 0.031217037,
    timeTotal = 0.943848677
end SimulationResult;
""

"/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile.fmu"


RoomHeating_OM_RH
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: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'RoomHeating_OM_RH', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "assert            | warning | The following assertion has been violated during initialization at time 0.000000
|                 | |       | fanspeed >= 0.01
assert            | warning | UTRC-FCU-002: FCU air damper should be opened at least 0.10.
LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.373141132,
    timeBackend = 0.01311629,
    timeSimCode = 0.00278466,
    timeTemplates = 0.006034152,
    timeCompile = 0.727407566,
    timeSimulation = 0.07729369300000001,
    timeTotal = 1.19990127
end SimulationResult;
"Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions(\"-d=initialization\").
"

"/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH.fmu"


WaterTank_Control
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: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/WaterTank_Control_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'WaterTank_Control', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.110235931,
    timeBackend = 0.002992975,
    timeSimCode = 0.000948426,
    timeTemplates = 0.003111416,
    timeCompile = 0.6603449180000001,
    timeSimulation = 0.0281219,
    timeTotal = 0.805872653
end SimulationResult;
"Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions(\"-d=initialization\").
"

"/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/WaterTank_Control.fmu"


WaterTank_TestSingleWaterTank
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[/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation tank.valvecontrol <> 0.0, <> on Real numbers is only allowed inside functions.
[/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation tank.valvecontrol <> 0.0, <> on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'WaterTank_TestSingleWaterTank', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.09990927300000001,
    timeBackend = 0.008417324,
    timeSimCode = 0.00216984,
    timeTemplates = 0.005418665,
    timeCompile = 0.689660431,
    timeSimulation = 0.042010267,
    timeTotal = 0.847721627
end SimulationResult;
"[/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation tank.valvecontrol <> 0.0, <> on Real numbers is only allowed inside functions.
[/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation tank.valvecontrol <> 0.0, <> on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions(\"-d=initialization\").
"

"/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank.fmu"


BouncingBall
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record SimulationResult
    resultFile = "/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/BouncingBall_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'BouncingBall', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.131064837,
    timeBackend = 0.005521773000000001,
    timeSimCode = 0.001723018,
    timeTemplates = 0.003755886,
    timeCompile = 0.68249636,
    timeSimulation = 0.03261838800000001,
    timeTotal = 0.85731179
end SimulationResult;
""

"/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile/BouncingBall.fmu"



unzip -q FmuExportCrossCompile.fmu -d FmuExportCrossCompile.fmutmp
make check-files
make[1]: Entering directory '/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile'
FmuExportCrossCompile.fmutmp/binaries/win32/FmuExportCrossCompile.dll: PE32 executable (DLL) (console) Intel 80386, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/win64/FmuExportCrossCompile.dll: PE32+ executable (DLL) (console) x86-64, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/darwin64/FmuExportCrossCompile.dylib: Mach-O 64-bit x86_64 dynamically linked shared library, flags:<NOUNDEFS|DYLDLINK|TWOLEVEL|NO_REEXPORTED_DYLIBS>
FmuExportCrossCompile.fmutmp/binaries/linux32/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, Intel 80386, version 1 (SYSV), dynamically linked, BuildID[sha1]=4f90895ccc9f69fdcc681d63fb4c4de2569e6b79, not stripped
FmuExportCrossCompile.fmutmp/binaries/linux64/FmuExportCrossCompile.so: ELF 64-bit LSB shared object, x86-64, version 1 (SYSV), dynamically linked, BuildID[sha1]=4286109bd94ee615fdf2f40321eb2ac45fee0961, not stripped
FmuExportCrossCompile.fmutmp/binaries/arm-linux-gnueabihf/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, ARM, EABI5 version 1 (SYSV), dynamically linked, BuildID[sha1]=6c21c8bfa79d0c02d594c7963503e654bab61e1b, not stripped
make[1]: Leaving directory '/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile'
make: Leaving directory '/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.17/testsuite/special/FmuExportCrossCompile'