Skip to content

Console Output

+ make -C testsuite/special/FmuExportCrossCompile/ test
make: Entering directory '/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile'
rm -rf *.json *.xml *.html *.fmu* *.c *.makefile *.log *.o *.libs *.h *.mat *.csv Test_FMUs
../../../build/bin/omc fmuExportCrossCompile.mos

""

""

""

""
{"x86_64-apple-darwin15 docker run docker.openmodelica.org/osxcross-omsimulator:v2.0","arm-linux-gnueabihf docker run docker.openmodelica.org/armcross-omsimulator:v2.0","x86_64-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13","i686-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13-i386","x86_64-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0","i686-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0"}
FmuExportCrossCompile

bf718ef8a77e8b7957852de522644e8f21fadd5e9846f5e73e43c45aa16cfebc
b187193ced159acb2b871780bcb1fc6ff7b1518fd6422ce49bcc62db160ea416
41b7088e6f9edbdbb638fc62c89aabd7c1a6710699ccfd2140d9457548cd760f
343f0084bcb58e019b0a6e9d739c3a0396ec32cb20cf05f83e53b39ee74b0881
0fa62388f1734a54593bbd6304b0874f62105e6af10f51101ec8717c1b6fd948
dc46c51060830743857fe10818ad79b9fa01297acfeacedfbbe08586266710a9
f1532a2118ede1e675afb3b78f70b85b585ab5c56e8f64bcd6b206a345346816
5f6d93517e220d29d68ed90956b732a2c5e7198c8a39d1fe635d566e25b0b950
81c433b27aadc03572108dfdbdfa831f067dfcbfcb01cfe9b82d0f09ab355e20
8230f54ac5f6bf796e358e6775d3edcf1eea48c79637f0bd4600728ff0ef94dd
f4af2e9d48d9f1d180caac230e8a31204570a872b94d42e28c3d8afe4552796d
432611a7685773fdef73c9acf1e7399069ce1f40bc8143f28d79fca176a08268


record SimulationResult
    resultFile = "/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 0.45, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'FmuExportCrossCompile', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.5801834259999999,
    timeBackend = 0.004200038000000001,
    timeSimCode = 0.001147513,
    timeTemplates = 0.030231964,
    timeCompile = 0.624557777,
    timeSimulation = 0.027432504,
    timeTotal = 1.267929383
end SimulationResult;
""

"/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile.fmu"


RoomHeating_OM_RH
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: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'RoomHeating_OM_RH', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "assert            | warning | The following assertion has been violated during initialization at time 0.000000
|                 | |       | fanspeed >= 0.01
assert            | warning | UTRC-FCU-002: FCU air damper should be opened at least 0.10.
LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.6544340449999999,
    timeBackend = 0.014039503,
    timeSimCode = 0.002903556,
    timeTemplates = 0.034223541,
    timeCompile = 0.8121946369999999,
    timeSimulation = 0.058498382,
    timeTotal = 1.576440349
end SimulationResult;
"Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").
"

"/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH.fmu"


WaterTank_Control
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record SimulationResult
    resultFile = "/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/WaterTank_Control_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'WaterTank_Control', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.720971755,
    timeBackend = 0.002785074,
    timeSimCode = 0.0005897560000000001,
    timeTemplates = 0.019712494,
    timeCompile = 0.495304404,
    timeSimulation = 0.017709778,
    timeTotal = 1.25720622
end SimulationResult;
""

"/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/WaterTank_Control.fmu"


WaterTank_TestSingleWaterTank

edf21d240badd6c62933a7647467d839290b64efc852569639ecc520237f40d2
26966d13a16606c4555c092cfc81a9d119e9fa59deaabde68d9951b7a7becf66
84c575782dbb08e3e94f80edcff23a3bb0d4134c198edf4fbed6aa227ab1b13b
149f4adbb14ecdf12e26223b1f940e31243567a8abab0d71bdc25c91f847a617
db44edec1ce6070ab37a3e694ad970cae14ce388e82186a916e5cb83c47300b4
b65361a2742ad5c2815b0a4c3930375e71c035394e8c4c2f1ff30f6ade72227c
8a689ab48d88bc9b61d0e9c488cde935838f71da2136c78da76c3202451ddf18
de58f4a055b5b1cbb71f2f6e8e623bc342835041b5114142a3c09f5fe2d70dc0
2d45cd7b6601dcb33ccf9b84f73fc2387487e9dc6f91c3f0019df7b5d0cfcf9c
b4f8b976853693162dc389b19e8495c50e870d371be65503ba1b9db9e988a721
b2069bc2f237d075cf195b5683ee4393d4164c83a66f3611c406d89d42e46d88
0e613fefba0e62cdacb24e4ee9844102c0393e5ddcf4f0369e05c9e58fe7d864
[/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
[/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'WaterTank_TestSingleWaterTank', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.633113886,
    timeBackend = 0.011748265,
    timeSimCode = 0.002804,
    timeTemplates = 0.026592538,
    timeCompile = 0.852758761,
    timeSimulation = 0.03780035,
    timeTotal = 1.56495175
end SimulationResult;
"[/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
[/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").
"

"/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank.fmu"



unzip -q FmuExportCrossCompile.fmu -d FmuExportCrossCompile.fmutmp
make check-files
make[1]: Entering directory '/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile'
FmuExportCrossCompile.fmutmp/binaries/win32/FmuExportCrossCompile.dll: PE32 executable (DLL) (console) Intel 80386, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/win64/FmuExportCrossCompile.dll: PE32+ executable (DLL) (console) x86-64, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/darwin64/FmuExportCrossCompile.dylib: Mach-O 64-bit x86_64 dynamically linked shared library, flags:<NOUNDEFS|DYLDLINK|TWOLEVEL|NO_REEXPORTED_DYLIBS>
FmuExportCrossCompile.fmutmp/binaries/linux32/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, Intel 80386, version 1 (SYSV), dynamically linked, BuildID[sha1]=c0a066fe3c13f4324f9bd4e5de7b5be366adb990, not stripped
FmuExportCrossCompile.fmutmp/binaries/linux64/FmuExportCrossCompile.so: ELF 64-bit LSB shared object, x86-64, version 1 (SYSV), dynamically linked, BuildID[sha1]=44bab24e6338793dbfa3c53cb80501be262e3a69, not stripped
FmuExportCrossCompile.fmutmp/binaries/arm-linux-gnueabihf/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, ARM, EABI5 version 1 (SYSV), dynamically linked, BuildID[sha1]=5768fb3ed2631961375b5c2bf2b226e2790b0515, not stripped
make[1]: Leaving directory '/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile'
make: Leaving directory '/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile'