+ make -C testsuite/special/FmuExportCrossCompile/ test
make: Entering directory '/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile'
rm -rf *.json *.xml *.html *.fmu* *.c *.makefile *.log *.o *.libs *.h *.mat *.csv Test_FMUs
../../../build/bin/omc fmuExportCrossCompile.mos

""

""

""

""
{"x86_64-apple-darwin15 docker run docker.openmodelica.org/osxcross-omsimulator:v2.0","arm-linux-gnueabihf docker run docker.openmodelica.org/armcross-omsimulator:v2.0","x86_64-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13","i686-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13-i386","x86_64-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0","i686-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0"}
FmuExportCrossCompile

a72b73a0703096b4b33895297180532f4dab45b0b44d31c664bed9833377e76e
cc99607868072b573f4afb7e263c362ec99c7121fa65548292a50f19c0e741b7
b73fb4f99e2cde164d0b33eb00e4cb8c7a2eff948c5003340d829f03f846e1bd
6ca3b0702a7b4b0cf04c684095e71d7afcf07b889ab14260602a955baf30386f
9e14fed35ded4d3ba95d53d4745ea58ca13f8fd9554d09f439eb601f9a2da1ea
b37341c8992cc3d030fe746b02faef9486f54b55b093ebbc1247fbeaaf8efb83
8b7e8594a1444ea90c6a95d9512502c2c49b9276cfecd1dbd8dd8c391d8dc6f8
39abcaa065f48feda90c0505c211851da8ae86531be1d83b4f0870df9ba52b58
cdcaaccbd203975cef58461b4b8aaeb8a301df200db6e71940af98bbe65a56c0
83b01b5bfef2c8839151af41c4b0f65dce442412d2a6357549dc7b5feb721c1d
ca9a1560f46fbbc74238a97c565e5095c6ed79a5b8aa81616468919259241774
2696972d068b9ede9811cf2c9d6535b9e0b34b29cb767acb42fb29866365bea6


record SimulationResult
    resultFile = "/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 0.45, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'FmuExportCrossCompile', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.35384659,
    timeBackend = 0.002450015,
    timeSimCode = 0.0006935610000000001,
    timeTemplates = 0.003285412,
    timeCompile = 0.389854528,
    timeSimulation = 0.018638439,
    timeTotal = 0.7688927679999999
end SimulationResult;
""

"/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile.fmu"


RoomHeating_OM_RH

0ec654667b7e76edd475ff30adf1d44ee5a5b4e1158672ed7d96506b71d8b085
f31cec0462159ef3220ab84652b658c30d999a88dcb00bfd9e1d37a1ff9716ee
48cc10e3d7ad5aa381455c71de77fcd4e784622eba0bfb6c42a92372700b5a4a
446e812d82b288777aebbd61a54e93bfbf8db7be6baf52b690d52ab7c15a00e8
edbf61b2b80c5609cad399c2785acdf2483d0aa7be166b4bef1600ba1498463e
b1c4ae1fb554e9f3eedd5494b6e7b5c764d1179b0da38223b352f2d3d1d55da7
b5c666c57ea25cdaf2af9124af2a4b4d4a28d0a786da4073041c75340fcd1572
9e32edb118a3a91aa919d33de73210b627f062d69e7f9f2fbad798f0d9bd1803
264182017f002347a216462b4d2de00fd82430a72ccbed005ef0dc425ac22fea
400b74dbfa575eb124e6c16aef0870957d39ef0c4656f492ef7fb0f81bfbd50d
38025bebab8b57cca75d671d27fe17a6e4ed59382a333b004b595bb61938127a
cf1c134fe6c47c497dbf64401115c8b562782d9f2908508ea39ad9362555c5c2
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'RoomHeating_OM_RH', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "assert            | warning | The following assertion has been violated during initialization at time 0.000000
|                 | |       | fanspeed >= 0.01
assert            | warning | UTRC-FCU-002: FCU air damper should be opened at least 0.10.
LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.380464625,
    timeBackend = 0.006600941000000001,
    timeSimCode = 0.001389717,
    timeTemplates = 0.003505856,
    timeCompile = 0.3814213399999999,
    timeSimulation = 0.037135343,
    timeTotal = 0.810616878
end SimulationResult;
"Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").
"

"/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH.fmu"


WaterTank_Control
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record SimulationResult
    resultFile = "/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/WaterTank_Control_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'WaterTank_Control', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.343654954,
    timeBackend = 0.002332595,
    timeSimCode = 0.000470302,
    timeTemplates = 0.002890191,
    timeCompile = 0.362442303,
    timeSimulation = 0.014513492,
    timeTotal = 0.726391291
end SimulationResult;
""

"/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/WaterTank_Control.fmu"


WaterTank_TestSingleWaterTank

6ed4d2df5e1867f133d525e5d8b5a20eae5eae261200f238670cde58a3e1913b
89c4cf88db43d836000497630df5440b561d76fb4e5f61af18f82e33218d1568
4a80c974757216c952e5f41b18d7772835a3fd728fca58faafc0e00d992b01a2
ab22bf42d0d38fb16575863eef182c0f28bc1492e449fc65beaf0a303ff1fcae
3d6dfb2141789760c6db915ced6199792e18452f67004d84375229c35aaf1eb6
1d3f295ca755a851a8a6bc1a4e5315127b99ffb2fd7d7d98d12fd2b55d62817e
8ad9832268e882e18b6bf7b25a3a5563f443db67ea54bf09787ba86b0d67e579
e3948d1b6385116a952bcf87ca504c0c959dcd8e10d6f650f76f444ba9cbc27b
bdccb7e3469cccfe0e91228dd2b703b22e6842034ba25986a7b525c1c1271b5a
27d41488da6369425ec2a3761e0a65c05a730291d7593ba81ca3d47821b38ff8
c8f97d947cf57175bb017fa5a09eb440388266d3e26e8cdc2103c320c7e85824
7c9408a1dc06d1c3c4ba055794f65a5d959b1c6f346cbf84affa17a3dbc4ae39
[/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
[/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'WaterTank_TestSingleWaterTank', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.319763452,
    timeBackend = 0.00497953,
    timeSimCode = 0.001210661,
    timeTemplates = 0.003725387,
    timeCompile = 0.386211805,
    timeSimulation = 0.02526062,
    timeTotal = 0.741231225
end SimulationResult;
"[/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
[/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").
"

"/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank.fmu"



unzip -q FmuExportCrossCompile.fmu -d FmuExportCrossCompile.fmutmp
make check-files
make[1]: Entering directory '/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile'
FmuExportCrossCompile.fmutmp/binaries/win32/FmuExportCrossCompile.dll: PE32 executable (DLL) (console) Intel 80386, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/win64/FmuExportCrossCompile.dll: PE32+ executable (DLL) (console) x86-64, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/darwin64/FmuExportCrossCompile.dylib: Mach-O 64-bit x86_64 dynamically linked shared library, flags:<NOUNDEFS|DYLDLINK|TWOLEVEL|NO_REEXPORTED_DYLIBS>
FmuExportCrossCompile.fmutmp/binaries/linux32/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, Intel 80386, version 1 (SYSV), dynamically linked, BuildID[sha1]=10551434d3a51b3b5af8a8332206605996a0b6c8, not stripped
FmuExportCrossCompile.fmutmp/binaries/linux64/FmuExportCrossCompile.so: ELF 64-bit LSB shared object, x86-64, version 1 (SYSV), dynamically linked, BuildID[sha1]=340098b669a4b37e06a950d655da90947f122e71, not stripped
FmuExportCrossCompile.fmutmp/binaries/arm-linux-gnueabihf/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, ARM, EABI5 version 1 (SYSV), dynamically linked, BuildID[sha1]=9f642e54f17057d5a3a81a79aab19108109a844a, not stripped
make[1]: Leaving directory '/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile'
make: Leaving directory '/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile'