Skip to content

Console Output

+ make -C testsuite/special/FmuExportCrossCompile/ test
make: Entering directory '/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile'
rm -rf *.json *.xml *.html *.fmu* *.c *.makefile *.log *.o *.libs *.h *.mat *.csv Test_FMUs
../../../build/bin/omc fmuExportCrossCompile.mos

""

""

""

""
{"x86_64-apple-darwin15 docker run docker.openmodelica.org/osxcross-omsimulator:v2.0","arm-linux-gnueabihf docker run docker.openmodelica.org/armcross-omsimulator:v2.0","x86_64-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13","i686-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13-i386","x86_64-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0","i686-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0"}
FmuExportCrossCompile
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record SimulationResult
    resultFile = "/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 0.45, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'FmuExportCrossCompile', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.946339452,
    timeBackend = 0.007007790000000001,
    timeSimCode = 0.001974777,
    timeTemplates = 0.190149059,
    timeCompile = 1.025315363,
    timeSimulation = 0.07809223900000001,
    timeTotal = 2.249112906
end SimulationResult;
""

"/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile.fmu"


RoomHeating_OM_RH
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: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'RoomHeating_OM_RH', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "assert            | warning | The following assertion has been violated during initialization at time 0.000000
|                 | |       | fanspeed >= 0.01
assert            | warning | UTRC-FCU-002: FCU air damper should be opened at least 0.10.
LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 1.029767154,
    timeBackend = 0.013377045,
    timeSimCode = 0.002794541,
    timeTemplates = 0.007224940000000001,
    timeCompile = 0.7782601659999999,
    timeSimulation = 0.08205799600000001,
    timeTotal = 1.913652526
end SimulationResult;
"Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").
"

"/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH.fmu"


WaterTank_Control

141c89bb54e3439a73f2a00eb2eba24e36206a958d321d9ee6d06c98e45055a8
02f65e890eec49997b21188b334eceb57fdfd0fa2775630580d4a96bcec7bcda
d85fe7837c12ceacaeda48862374e08944710d148940622b1bd16b74a2eb7246
70c0de8cb3fe6dfd556493a1bea53abe6678e446a940924a3a71f94c6ecbecaf
e37075e69fea2e0f520ef21616473eadbec90350a5b2a9cda9d43a2e2086b159
16d04dac1d2e3ee3ff5d113c00e02d12d6c6effb4b9adba8bcf3e9872d5c13cd
2603d3c50a15d37dfc407c9eec1e6d55ace0e9496d0858ba810185b68099ae83
7e6f535211fbeb55fabee90c2271e1bcca6c36d67c400726e2b7fdd586ff6234
fa4954f3dfc9e363f0296604df086b1fd2a35915fa98d1be6ce18e6af7fc70d0
27d33039e8496df4c16abc47f11178310a3d04123e55bb171836afd47c78ba1a
19ab292bc9189272c9a557c62d6b6b9468999d3f15da724d3135e999968d7547
b49c27e353e7bd3d96e39d887798a183de5c23c16997719c06d41dbe37a578b6


record SimulationResult
    resultFile = "/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/WaterTank_Control_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'WaterTank_Control', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.62493303,
    timeBackend = 0.00458302,
    timeSimCode = 0.0009210420000000001,
    timeTemplates = 0.003843418,
    timeCompile = 0.639341643,
    timeSimulation = 0.025134195,
    timeTotal = 1.298906062
end SimulationResult;
""

"/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/WaterTank_Control.fmu"


WaterTank_TestSingleWaterTank
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[/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
[/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'WaterTank_TestSingleWaterTank', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.586103609,
    timeBackend = 0.009952074,
    timeSimCode = 0.002499796,
    timeTemplates = 0.006725447000000001,
    timeCompile = 0.632068521,
    timeSimulation = 0.034000886,
    timeTotal = 1.271495289
end SimulationResult;
"[/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
[/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").
"

"/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank.fmu"



unzip -q FmuExportCrossCompile.fmu -d FmuExportCrossCompile.fmutmp
make check-files
make[1]: Entering directory '/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile'
FmuExportCrossCompile.fmutmp/binaries/win32/FmuExportCrossCompile.dll: PE32 executable (DLL) (console) Intel 80386, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/win64/FmuExportCrossCompile.dll: PE32+ executable (DLL) (console) x86-64, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/darwin64/FmuExportCrossCompile.dylib: Mach-O 64-bit x86_64 dynamically linked shared library, flags:<NOUNDEFS|DYLDLINK|TWOLEVEL|NO_REEXPORTED_DYLIBS>
FmuExportCrossCompile.fmutmp/binaries/linux32/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, Intel 80386, version 1 (SYSV), dynamically linked, BuildID[sha1]=ee957159bf0da8ff294dde594411218f201495ed, not stripped
FmuExportCrossCompile.fmutmp/binaries/linux64/FmuExportCrossCompile.so: ELF 64-bit LSB shared object, x86-64, version 1 (SYSV), dynamically linked, BuildID[sha1]=69d1a8376b94c5d39ac791bbb21d04abacfdafc4, not stripped
FmuExportCrossCompile.fmutmp/binaries/arm-linux-gnueabihf/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, ARM, EABI5 version 1 (SYSV), dynamically linked, BuildID[sha1]=2b372e4d952a0886462a19fada04c2517b8b817a, not stripped
make[1]: Leaving directory '/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile'
make: Leaving directory '/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile'