Skip to content

Console Output

+ make -C testsuite/special/FmuExportCrossCompile/ test
make: Entering directory '/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile'
rm -rf *.json *.xml *.html *.fmu* *.c *.makefile *.log *.o *.libs *.h *.mat *.csv Test_FMUs
../../../build/bin/omc fmuExportCrossCompile.mos

""

""

""

""
{"x86_64-apple-darwin15 docker run docker.openmodelica.org/osxcross-omsimulator:v2.0","arm-linux-gnueabihf docker run docker.openmodelica.org/armcross-omsimulator:v2.0","x86_64-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13","i686-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13-i386","x86_64-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0","i686-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0"}
FmuExportCrossCompile
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record SimulationResult
    resultFile = "/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 0.45, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'FmuExportCrossCompile', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.401564069,
    timeBackend = 0.002827427,
    timeSimCode = 0.0008235460000000001,
    timeTemplates = 0.010901252,
    timeCompile = 0.471457071,
    timeSimulation = 0.019565065,
    timeTotal = 0.907284244
end SimulationResult;
""

"/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile.fmu"


RoomHeating_OM_RH
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: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'RoomHeating_OM_RH', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "assert            | warning | The following assertion has been violated during initialization at time 0.000000
|                 | |       | fanspeed >= 0.01
assert            | warning | UTRC-FCU-002: FCU air damper should be opened at least 0.10.
LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.5245545580000001,
    timeBackend = 0.007875503000000001,
    timeSimCode = 0.001692276,
    timeTemplates = 0.008913010000000001,
    timeCompile = 0.548419204,
    timeSimulation = 0.039153313,
    timeTotal = 1.130724533
end SimulationResult;
"Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").
"

"/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH.fmu"


WaterTank_Control
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record SimulationResult
    resultFile = "/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/WaterTank_Control_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'WaterTank_Control', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.442728055,
    timeBackend = 0.002672677,
    timeSimCode = 0.000567215,
    timeTemplates = 0.005658983,
    timeCompile = 0.488966738,
    timeSimulation = 0.022944018,
    timeTotal = 0.963664633
end SimulationResult;
""

"/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/WaterTank_Control.fmu"


WaterTank_TestSingleWaterTank
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[/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
[/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'WaterTank_TestSingleWaterTank', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.258389532,
    timeBackend = 0.005710719,
    timeSimCode = 0.001405117,
    timeTemplates = 0.00500807,
    timeCompile = 0.49513163,
    timeSimulation = 0.034211487,
    timeTotal = 0.79999728
end SimulationResult;
"[/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
[/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").
"

"/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank.fmu"



unzip -q FmuExportCrossCompile.fmu -d FmuExportCrossCompile.fmutmp
make check-files
make[1]: Entering directory '/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile'
FmuExportCrossCompile.fmutmp/binaries/win32/FmuExportCrossCompile.dll: PE32 executable (DLL) (console) Intel 80386, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/win64/FmuExportCrossCompile.dll: PE32+ executable (DLL) (console) x86-64, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/darwin64/FmuExportCrossCompile.dylib: Mach-O 64-bit x86_64 dynamically linked shared library, flags:<NOUNDEFS|DYLDLINK|TWOLEVEL|NO_REEXPORTED_DYLIBS>
FmuExportCrossCompile.fmutmp/binaries/linux32/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, Intel 80386, version 1 (SYSV), dynamically linked, BuildID[sha1]=0296174eec0a7e83969f02449acdfd1b1575a1e0, not stripped
FmuExportCrossCompile.fmutmp/binaries/linux64/FmuExportCrossCompile.so: ELF 64-bit LSB shared object, x86-64, version 1 (SYSV), dynamically linked, BuildID[sha1]=eea82c8b3508812dd3b656c63d06c06507c714ff, not stripped
FmuExportCrossCompile.fmutmp/binaries/arm-linux-gnueabihf/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, ARM, EABI5 version 1 (SYSV), dynamically linked, BuildID[sha1]=5825da3840f09f7dafbbb100ce6855908c0c6fb8, not stripped
make[1]: Leaving directory '/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile'
make: Leaving directory '/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile'