Failed
tests / testsuite-gcc / simulation_modelica_commonSubExp.ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1.mos (from (result.xml))
Stacktrace
Output mismatch (see stdout for details)
Standard Output
+ ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1 ... equation mismatch [time: 25] ==== Log /tmp/omc-rtest-unknown/simulation/modelica/commonSubExp/ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1.mos_temp3847/log-ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1.mos true "" true "Warning: Requested package Modelica of version 3.2.3, but this package was already loaded with version 3.2.1. You might experience problems if these versions are incompatible. " record SimulationResult resultFile = "ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1_res.mat", simulationOptions = "startTime = 0.0, stopTime = 1000.0, numberOfIntervals = 500, tolerance = 1e-06, method = 'dassl', fileNamePrefix = 'ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1', options = '', outputFormat = 'mat', variableFilter = '.*', cflags = '', simflags = ''", messages = "LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_SUCCESS | info | The simulation finished successfully. " end SimulationResult; "Warning: Requested package Modelica of version 3.2.3, but this package was already loaded with version 3.2.1. You might experience problems if these versions are incompatible. [ThermoSysPro 3.2/WaterSteam/Connectors.mo:3:3-43:17:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidInlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [ThermoSysPro 3.2/WaterSteam/Connectors.mo:87:3-127:18:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidOutlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [ThermoSysPro 3.2/ElectroMechanics/Connectors.mo:3:3-36:24:writable] Warning: Connector .ThermoSysPro.ElectroMechanics.Connectors.MechanichalTorque is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [ThermoSysPro 3.2/Properties/WaterSteam/Common.mo:1494:3-1528:30:writable] Warning: sat.T was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [ThermoSysPro 3.2/Properties/WaterSteam/Common.mo:1494:3-1528:30:writable] Warning: sat.dpT was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [ThermoSysPro 3.2/Properties/WaterSteam/Common.mo:1552:3-1581:34:writable] Warning: sat.T was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [ThermoSysPro 3.2/Properties/WaterSteam/Common.mo:1552:3-1581:34:writable] Warning: sat.dpT was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [ThermoSysPro 3.2/Properties/WaterSteam/Common.mo:1552:3-1581:34:writable] Warning: sat.cpt was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [ThermoSysPro 3.2/Properties/WaterSteam/Common.mo:1552:3-1581:34:writable] Warning: sat.vt was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [ThermoSysPro 3.2/Properties/WaterSteam/Common.mo:1552:3-1581:34:writable] Warning: sat.vp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [ThermoSysPro 3.2/Properties/WaterSteam/Common.mo:1552:3-1581:34:writable] Warning: sat.vtt was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [ThermoSysPro 3.2/Properties/WaterSteam/Common.mo:1552:3-1581:34:writable] Warning: sat.vpp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [ThermoSysPro 3.2/Properties/WaterSteam/Common.mo:1552:3-1581:34:writable] Warning: sat.vtp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [ThermoSysPro 3.2/Properties/WaterSteam/IF97_packages.mo:1089:9-1089:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [ThermoSysPro 3.2/Properties/WaterSteam/IF97_packages.mo:851:9-851:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [ThermoSysPro 3.2/Properties/WaterSteam/IF97_packages.mo:784:9-784:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [ThermoSysPro 3.2/Properties/WaterSteam/Common.mo:162:3-214:22:writable] Warning: pro.x was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [ThermoSysPro 3.2/Properties/WaterSteam/Common.mo:252:3-295:26:writable] Warning: pro.duph was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [ThermoSysPro 3.2/Properties/WaterSteam/Common.mo:252:3-295:26:writable] Warning: pro.duhp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [ThermoSysPro 3.2/Properties/WaterSteam/Common.mo:252:3-295:26:writable] Warning: pro.x was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [ThermoSysPro 3.2/Properties/WaterSteam/Common.mo:1270:3-1340:18:writable] Warning: pro.duph was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [ThermoSysPro 3.2/Properties/WaterSteam/Common.mo:1270:3-1340:18:writable] Warning: pro.duhp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [ThermoSysPro 3.2/Properties/C3H3F5/C3H3F5_Ph.mo:2:1-131:14:writable] Warning: pro.u was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [ThermoSysPro 3.2/Properties/C3H3F5/C3H3F5_Ph.mo:2:1-131:14:writable] Warning: pro.cp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [ThermoSysPro 3.2/Properties/C3H3F5/C3H3F5_Ph.mo:2:1-131:14:writable] Warning: pro.ddhp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [ThermoSysPro 3.2/Properties/C3H3F5/C3H3F5_Ph.mo:2:1-131:14:writable] Warning: pro.ddph was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [ThermoSysPro 3.2/Properties/C3H3F5/C3H3F5_Ph.mo:2:1-131:14:writable] Warning: pro.duph was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [ThermoSysPro 3.2/Properties/C3H3F5/C3H3F5_Ph.mo:2:1-131:14:writable] Warning: pro.duhp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [ThermoSysPro 3.2/Properties/WaterSteamSimple/prop4_Ph_der.mo:179:3-182:49:writable] Warning: du1satp_der was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [ThermoSysPro 3.2/Properties/WaterSteamSimple/prop4_Ph_der.mo:179:3-182:49:writable] Warning: du2satp_der was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [ThermoSysPro 3.2/Properties/WaterSteamSimple/prop4_Ph.mo:76:3-76:60:writable] Warning: dh1satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [ThermoSysPro 3.2/Properties/WaterSteamSimple/prop4_Ph.mo:76:3-76:60:writable] Warning: dh2satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [ThermoSysPro 3.2/WaterSteam/Connectors.mo:87:3-127:18:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidOutlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [ThermoSysPro 3.2/WaterSteam/Connectors.mo:3:3-43:17:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidInlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [ThermoSysPro 3.2/ElectroMechanics/Connectors.mo:3:3-36:24:writable] Warning: Connector .ThermoSysPro.ElectroMechanics.Connectors.MechanichalTorque is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [ThermoSysPro 3.2/WaterSteam/Connectors.mo:87:3-127:18:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidOutlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [ThermoSysPro 3.2/WaterSteam/Connectors.mo:3:3-43:17:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidInlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [ThermoSysPro 3.2/WaterSteam/Connectors.mo:87:3-127:18:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidOutlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [ThermoSysPro 3.2/ElectroMechanics/Connectors.mo:3:3-36:24:writable] Warning: Connector .ThermoSysPro.ElectroMechanics.Connectors.MechanichalTorque is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [ThermoSysPro 3.2/WaterSteam/Connectors.mo:3:3-43:17:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidInlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). " 0 "" Files equal! 0 Equation mismatch: diff says: --- /tmp/omc-rtest-unknown/simulation/modelica/commonSubExp/ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1.mos_temp3847/equations-expected2020-01-16 10:07:25.542916482 +0000 +++ /tmp/omc-rtest-unknown/simulation/modelica/commonSubExp/ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1.mos_temp3847/equations-got2020-01-16 10:07:50.474793659 +0000 @@ -49,11 +49,10 @@ [ThermoSysPro 3.2/WaterSteam/Connectors.mo:87:3-127:18:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidOutlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [ThermoSysPro 3.2/WaterSteam/Connectors.mo:3:3-43:17:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidInlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [ThermoSysPro 3.2/WaterSteam/Connectors.mo:87:3-127:18:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidOutlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [ThermoSysPro 3.2/ElectroMechanics/Connectors.mo:3:3-36:24:writable] Warning: Connector .ThermoSysPro.ElectroMechanics.Connectors.MechanichalTorque is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [ThermoSysPro 3.2/WaterSteam/Connectors.mo:3:3-43:17:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidInlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). -[ThermoSysPro 3.2/WaterSteam/Machines/CentrifugalPump.mo:137:3-139:9:writable] Error: Missing else-clause in if-equation with non-parameter conditions. " 0 "" Files equal! Equation mismatch: omc-diff says: Failed '[' '"' Line 54: Text differs: expected: [ThermoSysPro got: " == 1 out of 1 tests failed [simulation/modelica/commonSubExp/ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1.mos_temp3847, time: 25]