Skip to content

Console Output

+ make -C testsuite/special/FmuExportCrossCompile/ test
make: Entering directory '/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile'
rm -rf *.json *.xml *.html *.fmu* *.c *.makefile *.log *.o *.libs *.h *.mat *.csv Test_FMUs
../../../build/bin/omc fmuExportCrossCompile.mos

""

""

""

""
{"x86_64-apple-darwin15 docker run docker.openmodelica.org/osxcross-omsimulator:v2.0","arm-linux-gnueabihf docker run docker.openmodelica.org/armcross-omsimulator:v2.0","x86_64-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13","i686-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13-i386","x86_64-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0","i686-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0"}
FmuExportCrossCompile

f5aa8810017ed624bc77bd6476aa7f5f1a92d607f1537705d4447fa3282b0215
24b10f3391aac3291f5eee52304e7fe05b38f64f18e839adedde4e41d7817501
a67d72f0dbdeafb0ae78968dd78b049bdf41c9b27002e659dd9e703f7092fe0c
1b3230542bc7bedcc7969082b82f1889373f2b936a7b4a0aab020fd5710a534c
89752109f2ec3b58999c7b02238fb2694cb74161002109d97e78cc72d4c5367e
b477f88dbd673fb75d2a968eb611e526070c0c227f349eca417a9b9991fa4b35
4f2bc5a52db63e97e5fb3150d242ee718e573f514e50974db034fcebacdcf862
a44c9095658062386700ce5c7b5d554ca0f363fea9aa52468d28c8399183cd7f
32f07fe782e87bd74a4198e7a51e00af53eae369fba60de2073611265aa5239a
6ffb7280d450a344a6f7a5d0b76a861ee914cfda46e3d85370521fa6d0b8c0ff
6544114329efd98b6b2b15ae6c1fbb749557f1bb96771f9f2a8b582ad885e5f7
f5d35b0b70afe2c217419cbe7dd2772e1db82f391d45fede2ffeebe5141252cc


record SimulationResult
    resultFile = "/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 0.45, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'FmuExportCrossCompile', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.554246931,
    timeBackend = 0.004510824,
    timeSimCode = 0.001268189,
    timeTemplates = 0.003787257,
    timeCompile = 0.6381997269999999,
    timeSimulation = 0.023255613,
    timeTotal = 1.225472057
end SimulationResult;
""

"/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile.fmu"


RoomHeating_OM_RH

ec44b1423d17adf07a7fd0b031f2695f751921823d1eb739438f2a740669977a
4640c9375e170e319d16a7ce59fe46a04e79f3585f9a154c69f6ecbf13c053cc
0b171e355268e13545bff76267f04b1dc86517b96ec33fc1201c10f57dc2651f
f1b6dfc1aab4256c7dbd924d0d86e2a1414c20a81fd4e983ca498d5b4cb6f6fd
09a24ef104f594ef1d73f70d80f803c4f48eb258e1ad922fc6ec587f27113d55
9412930175c2224fe2fe7d5c8b587986bfc3984ff66beff73a9702591222a987
30264c60936de8baf4be0ff910e9311e857848fc1b330496861c023904b00e79
6491453fee23f6764c52d4adb1a9c155bc75f78f1fba57392409e06dba67863c
1dd934bc83634ad0a5515476ef56c46aeb5d320cdcd02e7f62e26c083044e17d
282bd31a55fae2fc2722b348d3dc5b3410e6cecf15b28bcf77994ed962541680
674d1d1625387f7f08bbe8d5e59de4b68be27dc840a39a5afd9cf0bacf68d4df
705d6b77da214465b0e4c1bdf7ad8f6eb4651a131546e1bbe6c1aefafda5c35b
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'RoomHeating_OM_RH', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "assert            | warning | The following assertion has been violated during initialization at time 0.000000
|                 | |       | fanspeed >= 0.01
assert            | warning | UTRC-FCU-002: FCU air damper should be opened at least 0.10.
LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.67891469,
    timeBackend = 0.02256346,
    timeSimCode = 0.004490405,
    timeTemplates = 0.060152467,
    timeCompile = 0.806576433,
    timeSimulation = 0.078915068,
    timeTotal = 1.651746652
end SimulationResult;
"Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").
"

"/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH.fmu"


WaterTank_Control
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record SimulationResult
    resultFile = "/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/WaterTank_Control_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'WaterTank_Control', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.666698838,
    timeBackend = 0.005406541,
    timeSimCode = 0.0008589170000000001,
    timeTemplates = 0.006386494,
    timeCompile = 0.6246948699999999,
    timeSimulation = 0.018789328,
    timeTotal = 1.322964237
end SimulationResult;
""

"/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/WaterTank_Control.fmu"


WaterTank_TestSingleWaterTank
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[/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
[/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'WaterTank_TestSingleWaterTank', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.5739344980000001,
    timeBackend = 0.009525525,
    timeSimCode = 0.002402079,
    timeTemplates = 0.004974640999999891,
    timeCompile = 0.599666252,
    timeSimulation = 0.052795066,
    timeTotal = 1.243454035
end SimulationResult;
"[/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
[/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").
"

"/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank.fmu"



unzip -q FmuExportCrossCompile.fmu -d FmuExportCrossCompile.fmutmp
make check-files
make[1]: Entering directory '/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile'
FmuExportCrossCompile.fmutmp/binaries/win32/FmuExportCrossCompile.dll: PE32 executable (DLL) (console) Intel 80386, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/win64/FmuExportCrossCompile.dll: PE32+ executable (DLL) (console) x86-64, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/darwin64/FmuExportCrossCompile.dylib: Mach-O 64-bit x86_64 dynamically linked shared library, flags:<NOUNDEFS|DYLDLINK|TWOLEVEL|NO_REEXPORTED_DYLIBS>
FmuExportCrossCompile.fmutmp/binaries/linux32/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, Intel 80386, version 1 (SYSV), dynamically linked, BuildID[sha1]=f32b7bf3cbb3715b722eec60b0f45c0a35bf4db8, not stripped
FmuExportCrossCompile.fmutmp/binaries/linux64/FmuExportCrossCompile.so: ELF 64-bit LSB shared object, x86-64, version 1 (SYSV), dynamically linked, BuildID[sha1]=2640d15945c9a0312ed73fb4e4aba31e1bee3a0f, not stripped
FmuExportCrossCompile.fmutmp/binaries/arm-linux-gnueabihf/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, ARM, EABI5 version 1 (SYSV), dynamically linked, BuildID[sha1]=46799417ba2784e8137e8a6d630958f9088973cb, not stripped
make[1]: Leaving directory '/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile'
make: Leaving directory '/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile'