Failed
tests / testsuite-gcc / simulation_modelica_initialization.OverdeterminedInitialization.Fluid.TwoVolumesEquationsFullSteadyStateMassAndEnergy.mos (from (result.xml))
Stacktrace
Output mismatch (see stdout for details)
Standard Output
+ OverdeterminedInitialization.Fluid.TwoVolumesEquationsFullSteadyStateMassAndEnergy... equation mismatch [time: 0] ==== Log /tmp/omc-rtest-unknown/simulation/modelica/initialization/OverdeterminedInitialization.Fluid.TwoVolumesEquationsFullSteadyStateMassAndEnergy.mos_temp7276/log-OverdeterminedInitialization.Fluid.TwoVolumesEquationsFullSteadyStateMassAndEnergy.mos false "Error: Failed to load package Modelica (default) using MODELICAPATH /var/lib/jenkins2/ws/OpenModelica_maintenance_v1.14_2/build/bin/../lib/omlibrary. " true "" true "" {"",""} "[simulation/modelica/initialization/OverdeterminedInitialization.mo:3:3-3:41:writable] Error: Base class Modelica.Icons.ExamplesPackage not found in scope OverdeterminedInitialization. Error: Class OverdeterminedInitialization.Fluid.TwoVolumesEquationsFullSteadyStateMassAndEnergy not found in scope . Error: Error occurred while flattening model OverdeterminedInitialization.Fluid.TwoVolumesEquationsFullSteadyStateMassAndEnergy " Equation mismatch: diff says: --- /tmp/omc-rtest-unknown/simulation/modelica/initialization/OverdeterminedInitialization.Fluid.TwoVolumesEquationsFullSteadyStateMassAndEnergy.mos_temp7276/equations-expected2019-10-27 11:24:02.356645439 +0000 +++ /tmp/omc-rtest-unknown/simulation/modelica/initialization/OverdeterminedInitialization.Fluid.TwoVolumesEquationsFullSteadyStateMassAndEnergy.mos_temp7276/equations-got2019-10-27 11:24:02.500643817 +0000 @@ -1,22 +1,12 @@ +false +"Error: Failed to load package Modelica (default) using MODELICAPATH /var/lib/jenkins2/ws/OpenModelica_maintenance_v1.14_2/build/bin/../lib/omlibrary. +" true "" true "" -true -"" - -Nonlinear iteration variables with default zero start attribute in NLSJac0. (5) -======================================== -1: $DER.T1:VARIABLE(stateSelect=StateSelect.prefer ) type: Real -2: $DER.p1:VARIABLE(stateSelect=StateSelect.prefer ) type: Real -3: $DER.T2:VARIABLE(stateSelect=StateSelect.prefer ) type: Real -4: p1:VARIABLE(stateSelect=StateSelect.prefer ) type: Real -5: T2:VARIABLE(stateSelect=StateSelect.prefer ) type: Real - -Info: Only non-linear iteration variables in non-linear eqation systems require start values. All other start values have no influence on convergence and are ignored. Use "-d=dumpLoops" to show all loops. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=dumpLoops") - -{"OverdeterminedInitialization.Fluid.TwoVolumesEquationsFullSteadyStateMassAndEnergy","OverdeterminedInitialization.Fluid.TwoVolumesEquationsFullSteadyStateMassAndEnergy_init.xml"} -"Notification: It was not possible to check the given initialization system for consistency symbolically, because the relevant equations are part of an algebraic loop. This is not supported yet. -Warning: The initial conditions are over specified. The following 1 initial equations are redundant, so they are removed from the initialization sytem: -$DER.M2 = 0.0. +{"",""} +"[simulation/modelica/initialization/OverdeterminedInitialization.mo:3:3-3:41:writable] Error: Base class Modelica.Icons.ExamplesPackage not found in scope OverdeterminedInitialization. +Error: Class OverdeterminedInitialization.Fluid.TwoVolumesEquationsFullSteadyStateMassAndEnergy not found in scope . +Error: Error occurred while flattening model OverdeterminedInitialization.Fluid.TwoVolumesEquationsFullSteadyStateMassAndEnergy " Equation mismatch: omc-diff says: Failed 't' 'f' Line 1: Text differs: expected: true got: false == 1 out of 1 tests failed [simulation/modelica/initialization/OverdeterminedInitialization.Fluid.TwoVolumesEquationsFullSteadyStateMassAndEnergy.mos_temp7276, time: 0]