Failed
tests / testsuite-clang / simulation_modelica_inheritances.Ticket4258a.mos (from (result.xml))
Stacktrace
Output mismatch (see stdout for details)
Standard Output
+ Ticket4258a.mos [BUG: #4258] ... equation mismatch [time: 0] ==== Log /tmp/omc-rtest-unknown/simulation/modelica/inheritances/Ticket4258a.mos_temp188/log-Ticket4258a.mos false "Error: Failed to load package Modelica (default) using MODELICAPATH /var/lib/jenkins/ws/OpenModelica_maintenance_v1.14_2/build/bin/../lib/omlibrary. " true "" record SimulationResult resultFile = "", simulationOptions = "startTime = 0.0, stopTime = 200.0, numberOfIntervals = 1000, tolerance = 1e-05, method = 'dassl', fileNamePrefix = 'simple_BasicHX_water_gas', options = '', outputFormat = 'mat', variableFilter = '.*', cflags = '', simflags = ''", messages = "Failed to build model: simple_BasicHX_water_gas" end SimulationResult; "[simulation/modelica/inheritances/Ticket4258a.mo:3:3-3:77:writable] Error: Class SI.AbsolutePressure not found in scope simple_BasicHX_water_gas. Error: Error occurred while flattening model simple_BasicHX_water_gas " Equation mismatch: diff says: --- /tmp/omc-rtest-unknown/simulation/modelica/inheritances/Ticket4258a.mos_temp188/equations-expected2019-10-27 11:26:05.781670216 +0000 +++ /tmp/omc-rtest-unknown/simulation/modelica/inheritances/Ticket4258a.mos_temp188/equations-got2019-10-27 11:26:05.917670693 +0000 @@ -1,26 +1,13 @@ -true -"" +false +"Error: Failed to load package Modelica (default) using MODELICAPATH /var/lib/jenkins/ws/OpenModelica_maintenance_v1.14_2/build/bin/../lib/omlibrary. +" true "" record SimulationResult -resultFile = "simple_BasicHX_water_gas_res.mat", +resultFile = "", simulationOptions = "startTime = 0.0, stopTime = 200.0, numberOfIntervals = 1000, tolerance = 1e-05, method = 'dassl', fileNamePrefix = 'simple_BasicHX_water_gas', options = '', outputFormat = 'mat', variableFilter = '.*', cflags = '', simflags = ''", -messages = "LOG_SUCCESS | info | The initialization finished successfully without homotopy method. -LOG_SUCCESS | info | The simulation finished successfully. -" +messages = "Failed to build model: simple_BasicHX_water_gas" end SimulationResult; -"Warning: The model contains alias variables with conflicting start and/or nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. -Warning: Some equations could not be differentiated for following variables having attribute stateSelect=StateSelect.prefer. They will be treated as if they had stateSelect=StateSelect.default -======================================== -1: WT_Nachreformer.pipe_1.mediums[5].T -2: WT_Nachreformer.pipe_1.mediums[1].T -3: WT_Nachreformer.pipe_1.mediums[2].T -4: WT_Nachreformer.pipe_1.mediums[3].T -5: WT_Nachreformer.pipe_1.mediums[4].T -Please use -d=bltdump for more information. -Warning: Some equations could not be differentiated for following variables having attribute stateSelect=StateSelect.prefer. They will be treated as if they had stateSelect=StateSelect.default -======================================== -1: WT_Nachreformer.pipe_2.flowModel.m_flows[5] -Please use -d=bltdump for more information. -Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization"). +"[simulation/modelica/inheritances/Ticket4258a.mo:3:3-3:77:writable] Error: Class SI.AbsolutePressure not found in scope simple_BasicHX_water_gas. +Error: Error occurred while flattening model simple_BasicHX_water_gas " Equation mismatch: omc-diff says: Failed 't' 'f' Line 1: Text differs: expected: true got: false == 1 out of 1 tests failed [simulation/modelica/inheritances/Ticket4258a.mos_temp188, time: 0]