Skip to content

Console Output

+ make -C testsuite/special/FmuExportCrossCompile/ test
make: Entering directory '/var/lib/jenkins/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile'
rm -rf *.json *.xml *.html *.fmu* *.c *.makefile *.log *.o *.libs *.h *.mat *.csv Test_FMUs
../../../build/bin/omc fmuExportCrossCompile.mos

""

""

""

""
{"x86_64-apple-darwin15 docker run docker.openmodelica.org/osxcross-omsimulator:v2.0","arm-linux-gnueabihf docker run docker.openmodelica.org/armcross-omsimulator:v2.0","x86_64-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13","i686-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13-i386","x86_64-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0","i686-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0"}
FmuExportCrossCompile
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record SimulationResult
    resultFile = "/var/lib/jenkins/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 0.45, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'FmuExportCrossCompile', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.346013316,
    timeBackend = 0.002323834,
    timeSimCode = 0.000649279,
    timeTemplates = 0.003328039,
    timeCompile = 0.363944214,
    timeSimulation = 0.018648004,
    timeTotal = 0.735022884
end SimulationResult;
""

"/var/lib/jenkins/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile.fmu"


RoomHeating_OM_RH
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: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'RoomHeating_OM_RH', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "assert            | warning | The following assertion has been violated during initialization at time 0.000000
|                 | |       | fanspeed >= 0.01
assert            | warning | UTRC-FCU-002: FCU air damper should be opened at least 0.10.
LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.190694049,
    timeBackend = 0.007058133,
    timeSimCode = 0.001561111,
    timeTemplates = 0.005549971000000001,
    timeCompile = 0.401138031,
    timeSimulation = 0.03603325800000001,
    timeTotal = 0.6421234010000001
end SimulationResult;
"Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").
"

"/var/lib/jenkins/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH.fmu"


WaterTank_Control

bf2fbc35103ea3cbb2616c30cbe316a148c61d144ece3a57b114bcf9691d797d
2c56d6e1faa034187ab076bf11a5eb14aaa656f5a0e2b15999ad13516fd123d0
ea6f5185b6cbd700a0561fcc5499b39ea7a0746d7d8748ca98a091d9df161ba8
ffe2aebd903449c6b037c34bcaec50133beea497d7aa2f158a9ee4d754850b0f
91094a1b68141a7a2d1a6dab13e2e006472cb4b8f7eea1ba9b2caf748d83c483
b5dd5d5eb4ec4c6ec36b9f40d2213e2da10719c281e6b3ddae02a0d22e1b236b
ddf960b5e920bb5ef0fa9b23ff18660ff5934f9a06b4054d5d9263fd4bc08a12
9eed643618423836148021ea10ac86d96c672562dd5a8b1dd8630f4a14c5f1e4
93f5d48a80d0ce942080c9ffe1f16e6c2a576a28e141590341fcafe2bef747c8
c5377c900ba5ba34f20f4b1ac781c9ec64761325ef426c48789dcb5bd19a0a90
5baff276705c2652924ecde4426467246db324a4e52e3c6bbc83800e2182a90a
731a25f1036d17163d5496e4e25bbbff03ce7a8108c5ed09416c8c3f484ed778


record SimulationResult
    resultFile = "/var/lib/jenkins/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/WaterTank_Control_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'WaterTank_Control', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.343212227,
    timeBackend = 0.002409474,
    timeSimCode = 0.00052737,
    timeTemplates = 0.002961541,
    timeCompile = 0.3459193989999999,
    timeSimulation = 0.016725104,
    timeTotal = 0.711852809
end SimulationResult;
""

"/var/lib/jenkins/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/WaterTank_Control.fmu"


WaterTank_TestSingleWaterTank

0f99b698bf37fa9f114bde0626eed8cc3c8f11fb89d1ead43da017bd6520af96
51347fefcd61de593e3b6a3b67d7d71e6ee1596e94b2e0f19ea4f1b57d1b0054
ec17bb5d3e7345d1edad4f8a0a037b51bd2ba629717b3c038524aabfbf5c29f6
2f7a22493693932bf1003c4179cd6d987e3f287814824ba394428e530a3a6509
d11a0816389cf87928b436477c6157f55fe03b85e6348127b330b5dee3b4333d
9c008c9e8326ae436b60d41229f10b66dc4cf31c8495211cf15a3bd28b18ced0
43cda47e39f6e6cb0c2f0218e885a31fd666167f9b499354bea7d726de7d35e3
438b9cd67b2377d2b652aab391e5c22f28ed943c67c0bbefb52492affd80ac5d
9039093b105265dfb392ea7b9ef13493bf50d009bad8fa246fac457ae4971aa0
6945247564ca86877a0cb9ec56dfe948a063303b1098098086f102b7d7d3b12e
e856da4f81c3737c82575d34c8f32784c84a447a09f4721839f59f1615a87990
f703a85f0e63cbc50c426d604292dbb72e2e6ecacc1f3cdfd14f54b70e1af042
[/var/lib/jenkins/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
[/var/lib/jenkins/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'WaterTank_TestSingleWaterTank', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.361099853,
    timeBackend = 0.005411782,
    timeSimCode = 0.001329186,
    timeTemplates = 0.003550436,
    timeCompile = 0.385102713,
    timeSimulation = 0.026100839,
    timeTotal = 0.7826921910000001
end SimulationResult;
"[/var/lib/jenkins/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
[/var/lib/jenkins/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").
"

"/var/lib/jenkins/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank.fmu"



unzip -q FmuExportCrossCompile.fmu -d FmuExportCrossCompile.fmutmp
make check-files
make[1]: Entering directory '/var/lib/jenkins/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile'
FmuExportCrossCompile.fmutmp/binaries/win32/FmuExportCrossCompile.dll: PE32 executable (DLL) (console) Intel 80386, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/win64/FmuExportCrossCompile.dll: PE32+ executable (DLL) (console) x86-64, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/darwin64/FmuExportCrossCompile.dylib: Mach-O 64-bit x86_64 dynamically linked shared library, flags:<NOUNDEFS|DYLDLINK|TWOLEVEL|NO_REEXPORTED_DYLIBS>
FmuExportCrossCompile.fmutmp/binaries/linux32/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, Intel 80386, version 1 (SYSV), dynamically linked, BuildID[sha1]=87c5ffcb25c20567a5a1bdf18d8f20224a26e8a2, not stripped
FmuExportCrossCompile.fmutmp/binaries/linux64/FmuExportCrossCompile.so: ELF 64-bit LSB shared object, x86-64, version 1 (SYSV), dynamically linked, BuildID[sha1]=58f7250914f727b91994b2e44b3318a52fe5c5c5, not stripped
FmuExportCrossCompile.fmutmp/binaries/arm-linux-gnueabihf/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, ARM, EABI5 version 1 (SYSV), dynamically linked, BuildID[sha1]=248640dbdc8b215deec24a8b1a34be4d59fc8bf0, not stripped
make[1]: Leaving directory '/var/lib/jenkins/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile'
make: Leaving directory '/var/lib/jenkins/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile'