Skip to content

Console Output

+ make -C testsuite/special/FmuExportCrossCompile/ test
make: Entering directory '/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile'
rm -rf *.json *.xml *.html *.fmu* *.c *.makefile *.log *.o *.libs *.h *.mat *.csv Test_FMUs
../../../build/bin/omc fmuExportCrossCompile.mos

""

""

""

""
{"x86_64-apple-darwin15 docker run docker.openmodelica.org/osxcross-omsimulator:v2.0","arm-linux-gnueabihf docker run docker.openmodelica.org/armcross-omsimulator:v2.0","x86_64-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13","i686-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13-i386","x86_64-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0","i686-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0"}
FmuExportCrossCompile

432568d8050b4977fa653648273445f1fd57ad89f9a913e3062ae830f16aea2e
1aea9fa6bde67d8bbb30bd13e9d3f5493f59f4bab11a0a72b35a45d4a31c3938
461953de6ba5a2f06c4c1f254165d45d689d3a2b7a3139a0e5a20cbe363112fe
4a0bab25481b4dfe86ad93a195eed70ba3f4124b716c633448bc5cf2aab0281e
88202e55c9d05e3be59d6e5dced2dfeafec131a5015301352d083b86a742e8e4
6be028cd8319ee39f5bfc45accf04263adf50e46a1191cc0664e17b2c11bc9d7
711206d4f903e5cd70bdc2f99cc563c40b57ac9248a42a73047aaee8a9bf1a0f
06c923298373a99c2ebb83b591831e9ac49c8ee0e620f7833a25de98ad10e7c8
8d0b0e6500e79b46428bee7692fe986a9c0838ed52ce14e49826398a0779d472
2e00d5697a1c8671a312305517ceaf897bbd3cf83e7f26bae5c7d832c90e0c60
283c6dfa1a76b0102f8bc33d55c6db539c49225be3b23782f458b205193076cf
5d86ff07c57bd2861f1e09c8fe2bf43adbd181f8e10ecff4e5b9883de21a4697


record SimulationResult
    resultFile = "/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 0.45, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'FmuExportCrossCompile', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.455609826,
    timeBackend = 0.003095591,
    timeSimCode = 0.0008400360000000001,
    timeTemplates = 0.017851618,
    timeCompile = 0.603340294,
    timeSimulation = 0.028521517,
    timeTotal = 1.109412259
end SimulationResult;
""

"/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile.fmu"


RoomHeating_OM_RH
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: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'RoomHeating_OM_RH', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "assert            | warning | The following assertion has been violated during initialization at time 0.000000
|                 | |       | fanspeed >= 0.01
assert            | warning | UTRC-FCU-002: FCU air damper should be opened at least 0.10.
LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.536647357,
    timeBackend = 0.008259975000000001,
    timeSimCode = 0.001857066,
    timeTemplates = 0.019539246,
    timeCompile = 0.624995432,
    timeSimulation = 0.044815421,
    timeTotal = 1.236226036
end SimulationResult;
"Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").
"

"/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH.fmu"


WaterTank_Control

991fbd1157510125ddc4ebca4d6dbd7ca1f6b4441a16dc47b8da50a656622204
cbe4020a1acff319b07bc120d55fbde01c2f0c572d62214ca260ab841d5f0a9e
4218ebedfebee391080ad8ff90b7e1b3b88500bee3ef3631d81b8792399b1afc
cc31a9e6408770883013598cccaa2af5871dadf64858828a27ee42471e26b279
888da9ad3c65d42a31f684c9685373c746bd56ecec233a47e95de532b139bb71
06d01916f3a5d776a0d768119db0b642fee1d5bf702ea8101d46abbea6ec371b
46973d0729c26e77127ab101fa5498d1f572a64ef1c78f3a899c195fd29ee5c2
21ecf53bc695819cb4e768621bf6f52af30a1b66038ec1e246bd0bb4ea273b9b
1ca9b75693a6fd460095d85d1a0da8052e2e04b989daddf502b7828a47064d69
bbf2ffcd2d5be2acc150c8460004bd46610a85acd57a9130975a9d4f47f1a225
819126b47df87b08da037fbfa6a276c11da5dc749b19dbd14ca81419bebfb777
3f4b22f662c0ed09aae6d4a2ae6253d1120b7a3d3f5023409f73525052832a5f


record SimulationResult
    resultFile = "/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/WaterTank_Control_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'WaterTank_Control', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.495210548,
    timeBackend = 0.004408414,
    timeSimCode = 0.0009172220000000001,
    timeTemplates = 0.020346281,
    timeCompile = 0.570093057,
    timeSimulation = 0.01800165,
    timeTotal = 1.109119039
end SimulationResult;
""

"/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/WaterTank_Control.fmu"


WaterTank_TestSingleWaterTank

6c3e2c5233a9fa9dc42fc360352efb766fe77574bb2462267ad63dd436477963
440ae7bbcb185fc2276686f79eecc409b2705f5246d2c6e5d673be54c57c033a
bd4b511c584c14d600ff9ba0b83a68a786effb179fab94cccbe6e05dd834801a
7719cac5f28590a633888ccc7261ca6c0d0ec516c50f427e2caf2a8487feca3b
4cc1d93d6ae8f60ad5f68f898ba1220106e36c96cc3c45aed28b5aadda3fdb75
51ff9a3c5b81b1fdb870042c7c3efebc2aece61dbfd241054b24e51ea8fdec02
96405294d90ec987147dad53ae36e35b83a7a790c52dc85a2d6f9eedee69afb3
698ab0e5b3017b3e9a8d020777f8e3d3dd21527d88c60ef3454085d5255a09d3
a4ed539e8a7a00b4fbacc6a402848003b7dc8c8157321214d7de0cab138a39b7
8aff36042b01b7118bfe3337ebcb32103e701fe120533eba40ab5f225a888ab1
9702b9748943e4af3787af59d45b155d80d1125df411cf16d6e2b39084473eb5
205f425eb402e845de9759e68136bfdb483b85516b294c6f3af231cebaf8a74c
[/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
[/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'WaterTank_TestSingleWaterTank', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.484276614,
    timeBackend = 0.006146347000000001,
    timeSimCode = 0.001639227,
    timeTemplates = 0.020637959,
    timeCompile = 0.554230001,
    timeSimulation = 0.03365342900000001,
    timeTotal = 1.100737196
end SimulationResult;
"[/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
[/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").
"

"/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank.fmu"



unzip -q FmuExportCrossCompile.fmu -d FmuExportCrossCompile.fmutmp
make check-files
make[1]: Entering directory '/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile'
FmuExportCrossCompile.fmutmp/binaries/win32/FmuExportCrossCompile.dll: PE32 executable (DLL) (console) Intel 80386, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/win64/FmuExportCrossCompile.dll: PE32+ executable (DLL) (console) x86-64, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/darwin64/FmuExportCrossCompile.dylib: Mach-O 64-bit x86_64 dynamically linked shared library, flags:<NOUNDEFS|DYLDLINK|TWOLEVEL|NO_REEXPORTED_DYLIBS>
FmuExportCrossCompile.fmutmp/binaries/linux32/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, Intel 80386, version 1 (SYSV), dynamically linked, BuildID[sha1]=233a285367da22b29057234bb790482844cff3b9, not stripped
FmuExportCrossCompile.fmutmp/binaries/linux64/FmuExportCrossCompile.so: ELF 64-bit LSB shared object, x86-64, version 1 (SYSV), dynamically linked, BuildID[sha1]=dbcd4ab57201e3c501c93f9fdbe9e2434e074d5e, not stripped
FmuExportCrossCompile.fmutmp/binaries/arm-linux-gnueabihf/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, ARM, EABI5 version 1 (SYSV), dynamically linked, BuildID[sha1]=c386193814e954003789cba6ecad89c6702f8089, not stripped
make[1]: Leaving directory '/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile'
make: Leaving directory '/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile'