Skip to content

Console Output

+ make -C testsuite/special/FmuExportCrossCompile/ test
make: Entering directory '/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile'
rm -rf *.json *.xml *.html *.fmu* *.c *.makefile *.log *.o *.libs *.h *.mat *.csv Test_FMUs
../../../build/bin/omc fmuExportCrossCompile.mos

""

""

""

""
{"x86_64-apple-darwin15 docker run docker.openmodelica.org/osxcross-omsimulator:v2.0","arm-linux-gnueabihf docker run docker.openmodelica.org/armcross-omsimulator:v2.0","x86_64-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13","i686-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13-i386","x86_64-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0","i686-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0"}
FmuExportCrossCompile
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record SimulationResult
    resultFile = "/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 0.45, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'FmuExportCrossCompile', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.331170628,
    timeBackend = 0.002363833,
    timeSimCode = 0.000658335,
    timeTemplates = 0.003067884,
    timeCompile = 0.345704799,
    timeSimulation = 0.016558027,
    timeTotal = 0.6996455150000001
end SimulationResult;
""

"/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile.fmu"


RoomHeating_OM_RH
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: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'RoomHeating_OM_RH', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "assert            | warning | The following assertion has been violated during initialization at time 0.000000
|                 | |       | fanspeed >= 0.01
assert            | warning | UTRC-FCU-002: FCU air damper should be opened at least 0.10.
LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.418092803,
    timeBackend = 0.006565675,
    timeSimCode = 0.001415064,
    timeTemplates = 0.004819339000000001,
    timeCompile = 0.383905549,
    timeSimulation = 0.040269662,
    timeTotal = 0.855161137
end SimulationResult;
"Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").
"

"/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH.fmu"


WaterTank_Control
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record SimulationResult
    resultFile = "/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/WaterTank_Control_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'WaterTank_Control', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.365489407,
    timeBackend = 0.0023242,
    timeSimCode = 0.000480331,
    timeTemplates = 0.003052906,
    timeCompile = 0.369647907,
    timeSimulation = 0.016797316,
    timeTotal = 0.757883769
end SimulationResult;
""

"/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/WaterTank_Control.fmu"


WaterTank_TestSingleWaterTank

75c4b4092f186b68bdf364800e90723e312062f6c79763a0e10a40187ac8d7dd
a83e836b4f31a73b263fcd98bd561fac8f22d590df3394c30fb402a62ef93677
6d3a0cec4f1b34d2f329807a7244a1f62aa26636a877f547e3035620640fce96
07c35b08e81ac7320e830ac741b61bbc57ee1dd931b88de1779a7c59b086c64a
60d53fc3eecd2a8b189907bad02fc2914e04dc4b2ffb15b34b0bf181996a9ef8
d04eca17767c27be5d6d814567424cdc28041f3eda7275b5879b404ce527f5f5
b19ddef51ab9a772848e1afbbf4a3513ae6123d266c4e5bfb73eacea88daa2b9
beffdfa2196b8d3555c988d26e4a169142a391c65575b0c9fc17854491ba02ec
7a0b97790b566bebc94747777ada95ddb7f46c8f0fa1005fcbfba1dd0ed40710
d07a16a47cb49fce26552c453ecba5b0569932eb69ac0316337fb763f4c836f0
ee19079e53c42382e39850d02e51e1fe5a6b43c69d303377383df3d1b9c13459
3c4856a64f96ecdb276097eb424be9b08e1dec9f4c9c3e257566787965709f4e
[/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
[/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'WaterTank_TestSingleWaterTank', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.177484328,
    timeBackend = 0.004921491,
    timeSimCode = 0.001271125,
    timeTemplates = 0.004922703,
    timeCompile = 0.3541869879999999,
    timeSimulation = 0.027454034,
    timeTotal = 0.5703418979999999
end SimulationResult;
"[/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
[/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").
"

"/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank.fmu"



unzip -q FmuExportCrossCompile.fmu -d FmuExportCrossCompile.fmutmp
make check-files
make[1]: Entering directory '/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile'
FmuExportCrossCompile.fmutmp/binaries/win32/FmuExportCrossCompile.dll: PE32 executable (DLL) (console) Intel 80386, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/win64/FmuExportCrossCompile.dll: PE32+ executable (DLL) (console) x86-64, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/darwin64/FmuExportCrossCompile.dylib: Mach-O 64-bit x86_64 dynamically linked shared library, flags:<NOUNDEFS|DYLDLINK|TWOLEVEL|NO_REEXPORTED_DYLIBS>
FmuExportCrossCompile.fmutmp/binaries/linux32/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, Intel 80386, version 1 (SYSV), dynamically linked, BuildID[sha1]=8f29cac9203e4128d6174b37595f5df8c79454aa, not stripped
FmuExportCrossCompile.fmutmp/binaries/linux64/FmuExportCrossCompile.so: ELF 64-bit LSB shared object, x86-64, version 1 (SYSV), dynamically linked, BuildID[sha1]=8c6b5ffbef160017cd7e1f561a275d696f9179e0, not stripped
FmuExportCrossCompile.fmutmp/binaries/arm-linux-gnueabihf/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, ARM, EABI5 version 1 (SYSV), dynamically linked, BuildID[sha1]=4937c67e56a9be3dd385d638e9a25c99f54486a6, not stripped
make[1]: Leaving directory '/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile'
make: Leaving directory '/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile'