Skip to content

Console Output

+ make -C testsuite/special/FmuExportCrossCompile/ test
make: Entering directory '/var/lib/jenkins/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile'
rm -rf *.json *.xml *.html *.fmu* *.c *.makefile *.log *.o *.libs *.h *.mat *.csv Test_FMUs
../../../build/bin/omc fmuExportCrossCompile.mos

""

""

""

""
{"x86_64-apple-darwin15 docker run docker.openmodelica.org/osxcross-omsimulator:v2.0","arm-linux-gnueabihf docker run docker.openmodelica.org/armcross-omsimulator:v2.0","x86_64-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13","i686-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13-i386","x86_64-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0","i686-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0"}
FmuExportCrossCompile

b156e0d9e6623b9d636e782c9adf3680032c0462296285ef1c0f1f27e2b7b463
1f2123daab2fedb49eec2f28486a77e590ca26084452656331b5a99d82a5b3b9
71ba9b91de8691a8d656df1296a95ca48657c4846c3afaf878954b06c529553a
ae42015fcf3ece1a042149d3934c1c720a6b65452abb3621e2a811b99507c5b7
98c6d28f8a9a0623239b01536043dace24b73d50ef902245095cffa8701743e1
c1e552943860238f655d85fa0090cdec23bc620cf04deebe8cb89608f4db274e
2fd056ea5b9c67eb359ac66195248c5e8efb54f93a2ecba6db3d6731c2c36806
c50634098fb4b0fd65d1cab659a3d26c44133ff86411c611a2991d47bdb8ef5e
9a6ef04a471ca7284207b3e35e8d64162c903d69a7a0ddd092b69cf7c6850429
1fce08ad50b46c1ebbbddad7a5fb090b706013519e12acae999164a121614771
3758ae02043c276e80443777c6e81b3fea83df73c317f392b4455fda6c80bc2e
ac24410cd9c987be41d90fd28ae280af6fecb24bfb99d7fa5c85a42ac872f4e7


record SimulationResult
    resultFile = "/var/lib/jenkins/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 0.45, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'FmuExportCrossCompile', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.287272215,
    timeBackend = 0.003029086,
    timeSimCode = 0.000799613,
    timeTemplates = 0.002357982,
    timeCompile = 0.4917449349999999,
    timeSimulation = 0.027389376,
    timeTotal = 0.8127824769999999
end SimulationResult;
""

"/var/lib/jenkins/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile.fmu"


RoomHeating_OM_RH
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: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'RoomHeating_OM_RH', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "assert            | warning | The following assertion has been violated during initialization at time 0.000000
|                 | |       | fanspeed >= 0.01
assert            | warning | UTRC-FCU-002: FCU air damper should be opened at least 0.10.
LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.330919385,
    timeBackend = 0.010630821,
    timeSimCode = 0.002071283,
    timeTemplates = 0.002877531,
    timeCompile = 0.5935616530000001,
    timeSimulation = 0.05358111499999996,
    timeTotal = 0.993782869
end SimulationResult;
"Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").
"

"/var/lib/jenkins/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH.fmu"


WaterTank_Control
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record SimulationResult
    resultFile = "/var/lib/jenkins/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/WaterTank_Control_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'WaterTank_Control', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.289819886,
    timeBackend = 0.003461893,
    timeSimCode = 0.0006569270000000001,
    timeTemplates = 0.001901079,
    timeCompile = 0.480972965,
    timeSimulation = 0.026601288,
    timeTotal = 0.803559587
end SimulationResult;
""

"/var/lib/jenkins/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/WaterTank_Control.fmu"


WaterTank_TestSingleWaterTank
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[/var/lib/jenkins/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
[/var/lib/jenkins/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'WaterTank_TestSingleWaterTank', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.27758488,
    timeBackend = 0.007912947,
    timeSimCode = 0.001944102,
    timeTemplates = 0.002616045,
    timeCompile = 0.521917975,
    timeSimulation = 0.038277702,
    timeTotal = 0.850407583
end SimulationResult;
"[/var/lib/jenkins/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
[/var/lib/jenkins/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").
"

"/var/lib/jenkins/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank.fmu"



unzip -q FmuExportCrossCompile.fmu -d FmuExportCrossCompile.fmutmp
make check-files
make[1]: Entering directory '/var/lib/jenkins/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile'
FmuExportCrossCompile.fmutmp/binaries/win32/FmuExportCrossCompile.dll: PE32 executable (DLL) (console) Intel 80386, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/win64/FmuExportCrossCompile.dll: PE32+ executable (DLL) (console) x86-64, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/darwin64/FmuExportCrossCompile.dylib: Mach-O 64-bit x86_64 dynamically linked shared library, flags:<NOUNDEFS|DYLDLINK|TWOLEVEL|NO_REEXPORTED_DYLIBS>
FmuExportCrossCompile.fmutmp/binaries/linux32/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, Intel 80386, version 1 (SYSV), dynamically linked, BuildID[sha1]=ae5e1646c5cf9d42e724170e386f4885e7bdb295, not stripped
FmuExportCrossCompile.fmutmp/binaries/linux64/FmuExportCrossCompile.so: ELF 64-bit LSB shared object, x86-64, version 1 (SYSV), dynamically linked, BuildID[sha1]=c32d92004fb37da50949718714f9635a6472a884, not stripped
FmuExportCrossCompile.fmutmp/binaries/arm-linux-gnueabihf/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, ARM, EABI5 version 1 (SYSV), dynamically linked, BuildID[sha1]=7777050228f48b4384f4fa007e6516958d45130e, not stripped
make[1]: Leaving directory '/var/lib/jenkins/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile'
make: Leaving directory '/var/lib/jenkins/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile'