Skip to content

Failed

tests / testsuite-clang / simulation_libraries_msl32.Modelica.Fluid.Examples.TraceSubstances.RoomCO2WithControls.mos (from (result.xml))

Failing for the past 3 builds (Since #7 )
Took 0 ms.

Stacktrace

Output mismatch (see stdout for details)

Standard Output

 + Modelica.Fluid.Examples.TraceSubstances.RoomCO2WithControls                       ... execution failed

==== Log /tmp/omc-rtest-unknown/simulation/libraries/msl32/Modelica.Fluid.Examples.TraceSubstances.RoomCO2WithControls.mos_temp3940/log-Modelica.Fluid.Examples.TraceSubstances.RoomCO2WithControls.mos
"true
"
""
OpenModelicaModelTesting.Kind.SuppressedSimulation
Modelica.Fluid.Examples.TraceSubstances.RoomCO2WithControls
{"volume.medium.Xi[1]","volume.medium.T","volume.mC[1]","ductOut.mCs_scaled[1,1]","ductOut.mCs_scaled[2,1]","ductOut.mediums[1].Xi[1]","ductOut.mediums[1].T","ductOut.mediums[2].Xi[1]","ductOut.mediums[2].T","PID.I.y","ductIn.mCs_scaled[1,1]","ductIn.mCs_scaled[2,1]","ductIn.mediums[1].p","ductIn.mediums[1].Xi[1]","ductIn.mediums[1].T","ductIn.mediums[2].p","ductIn.mediums[2].Xi[1]","ductIn.mediums[2].T"}
loadModel(Modelica,3.2.1)
/var/lib/jenkins/workspace/OpenModelica_maintenance_v1.13/testsuite/simulation/libraries/msl32/Modelica.Fluid.Examples.TraceSubstances.RoomCO2WithControls.mos_temp3940

== 1 out of 1 tests failed [simulation/libraries/msl32/Modelica.Fluid.Examples.TraceSubstances.RoomCO2WithControls.mos_temp3940, time: 0]