Skip to content

Failed

tests / testsuite-clang / simulation_modelica_initialization.OverdeterminedInitialization.Fluid.TwoVolumesFullInitial.mos (from (result.xml))

Failing for the past 1 build (Since #7 )
Took 0 ms.

Stacktrace

Output mismatch (see stdout for details)

Standard Output

 + OverdeterminedInitialization.Fluid.TwoVolumesFullInitial                          ... equation mismatch [time: 0]

==== Log /tmp/omc-rtest-unknown/simulation/modelica/initialization/OverdeterminedInitialization.Fluid.TwoVolumesFullInitial.mos_temp4080/log-OverdeterminedInitialization.Fluid.TwoVolumesFullInitial.mos
false
"Error: Failed to load package Modelica (default) using MODELICAPATH /var/lib/jenkins/workspace/OpenModelica_maintenance_v1.13/build/lib/omlibrary.
"
true
""
true
""
{"",""}
"[simulation/modelica/initialization/OverdeterminedInitialization.mo:3:3-3:41:writable] Error: Base class Modelica.Icons.ExamplesPackage not found in scope OverdeterminedInitialization.
Error: Class OverdeterminedInitialization.Fluid.TwoVolumesFullInitial not found in scope .
Error: Error occurred while flattening model OverdeterminedInitialization.Fluid.TwoVolumesFullInitial
"

Equation mismatch: diff says:
--- /tmp/omc-rtest-unknown/simulation/modelica/initialization/OverdeterminedInitialization.Fluid.TwoVolumesFullInitial.mos_temp4080/equations-expected2018-12-11 10:54:27.506325298 +0000
+++ /tmp/omc-rtest-unknown/simulation/modelica/initialization/OverdeterminedInitialization.Fluid.TwoVolumesFullInitial.mos_temp4080/equations-got2018-12-11 10:54:27.578324547 +0000
@@ -1,14 +1,12 @@
+false
+"Error: Failed to load package Modelica (default) using MODELICAPATH /var/lib/jenkins/workspace/OpenModelica_maintenance_v1.13/build/lib/omlibrary.
+"
 true
 ""
 true
 ""
-true
-""
-{"OverdeterminedInitialization.Fluid.TwoVolumesFullInitial","OverdeterminedInitialization.Fluid.TwoVolumesFullInitial_init.xml"}
-"Warning: The model contains alias variables with conflicting start and/or nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts.
-Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: V1.medium.p = V1.p_start (V2.p_start = V1.p_start)
-Warning: The initial conditions are over specified. The following 1 initial equations are redundant, so they are removed from the initialization sytem:
-V1.medium.p = V1.p_start.
-Warning: Iteration variables with default zero start attribute in torn nonlinear equation system:
-V1.ports[2].m_flow:VARIABLE(flow=true min = -100000.0 max = 100000.0 unit = "kg/s" )  "Mass flow rate from the connection point into the component" type: Real  [2]
+{"",""}
+"[simulation/modelica/initialization/OverdeterminedInitialization.mo:3:3-3:41:writable] Error: Base class Modelica.Icons.ExamplesPackage not found in scope OverdeterminedInitialization.
+Error: Class OverdeterminedInitialization.Fluid.TwoVolumesFullInitial not found in scope .
+Error: Error occurred while flattening model OverdeterminedInitialization.Fluid.TwoVolumesFullInitial
 "

Equation mismatch: omc-diff says:
Failed 't' 'f'
Line 1: Text differs:
expected: true
got:      false

== 1 out of 1 tests failed [simulation/modelica/initialization/OverdeterminedInitialization.Fluid.TwoVolumesFullInitial.mos_temp4080, time: 0]