Skip to content

Failed

tests / testsuite-gcc / simulation_modelica_resolveLoops.ElectricalCircuit3.mos (from (result.xml))

Failing for the past 9 builds (Since #16 )
Took 0 ms.

Stacktrace

Output mismatch (see stdout for details)

Standard Output

 + ElectricalCircuit3                                                                ... equation mismatch [time: 0]

==== Log /tmp/omc-rtest-unknown/simulation/modelica/resolveLoops/ElectricalCircuit3.mos_temp8640/log-ElectricalCircuit3.mos
false
"Error: Failed to load package Modelica (3.2.1) using MODELICAPATH /var/lib/jenkins/workspace/OpenModelica_maintenance_v1.13/build/lib/omlibrary.
"
true
""
true
""
record SimulationResult
    resultFile = "",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 500, tolerance = 1e-06, method = 'dassl', fileNamePrefix = 'ElectricalCircuit3', options = '', outputFormat = 'mat', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "Failed to build model: ElectricalCircuit3"
end SimulationResult;
"[simulation/modelica/resolveLoops/ElectricalCircuit3.mo:3:3-4:71:writable] Error: Class Modelica.Electrical.Analog.Basic.Ground not found in scope ElectricalCircuit3.
Error: Error occurred while flattening model ElectricalCircuit3
"
{"Error opening file: /var/lib/jenkins/workspace/OpenModelica_maintenance_v1.13/testsuite/simulation/modelica/resolveLoops/ElectricalCircuit3.mos_temp8640/ElectricalCircuit3_res.mat"}

Equation mismatch: diff says:
--- /tmp/omc-rtest-unknown/simulation/modelica/resolveLoops/ElectricalCircuit3.mos_temp8640/equations-expected2019-01-31 14:12:45.562097035 +0000
+++ /tmp/omc-rtest-unknown/simulation/modelica/resolveLoops/ElectricalCircuit3.mos_temp8640/equations-got2019-01-31 14:12:45.654096599 +0000
@@ -1,57 +1,16 @@
-true
-""
+false
+"Error: Failed to load package Modelica (3.2.1) using MODELICAPATH /var/lib/jenkins/workspace/OpenModelica_maintenance_v1.13/build/lib/omlibrary.
+"
 true
 ""
 true
 ""
 record SimulationResult
-resultFile = "ElectricalCircuit3_res.mat",
+resultFile = "",
 simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 500, tolerance = 1e-06, method = 'dassl', fileNamePrefix = 'ElectricalCircuit3', options = '', outputFormat = 'mat', variableFilter = '.*', cflags = '', simflags = ''",
-messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
-LOG_SUCCESS       | info    | The simulation finished successfully.
-"
+messages = "Failed to build model: ElectricalCircuit3"
 end SimulationResult;
-"Notification: Model statistics after passing the front-end and creating the data structures used by the back-end:
-* Number of equations: 65
-* Number of variables: 65
-Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").
-Notification: Model statistics after passing the back-end for initialization:
-* Number of independent subsystems: 2
-* Number of states: 0 ()
-* Number of discrete variables: 0 ('-d=discreteinfo' for list of discrete vars)
-* Number of discrete states: 0 ('-d=discreteinfo' for list of discrete states)
-* Top-level inputs: 0
-Notification: Strong component statistics for initialization (26):
-* Single equations (assignments): 24
-* Array equations: 0
-* Algorithm blocks: 0
-* Record equations: 0
-* When equations: 0
-* If-equations: 0
-* Equation systems (linear and non-linear blocks): 0
-* Torn equation systems: 2
-* Mixed (continuous/discrete) equation systems: 0
-Notification: Torn system details for strict tearing set:
-* Linear torn systems: 2 {(1,100.0%) 2,(1,100.0%) 2}
-* Non-linear torn systems: 0
-Notification: Model statistics after passing the back-end for simulation:
-* Number of independent subsystems: 5
-* Number of states: 2 (capacitor.v,capacitor1.v)
-* Number of discrete variables: 0 ('-d=discreteinfo' for list of discrete vars)
-* Number of discrete states: 0 ('-d=discreteinfo' for list of discrete states)
-* Top-level inputs: 0
-Notification: Strong component statistics for simulation (18):
-* Single equations (assignments): 16
-* Array equations: 0
-* Algorithm blocks: 0
-* Record equations: 0
-* When equations: 0
-* If-equations: 0
-* Equation systems (linear and non-linear blocks): 0
-* Torn equation systems: 2
-* Mixed (continuous/discrete) equation systems: 0
-Notification: Torn system details for strict tearing set:
-* Linear torn systems: 2 {(1,100.0%) 2,(1,100.0%) 2}
-* Non-linear torn systems: 0
+"[simulation/modelica/resolveLoops/ElectricalCircuit3.mo:3:3-4:71:writable] Error: Class Modelica.Electrical.Analog.Basic.Ground not found in scope ElectricalCircuit3.
+Error: Error occurred while flattening model ElectricalCircuit3
 "
-{"Files Equal!"}
+{"Error opening file: /var/lib/jenkins/workspace/OpenModelica_maintenance_v1.13/testsuite/simulation/modelica/resolveLoops/ElectricalCircuit3.mos_temp8640/ElectricalCircuit3_res.mat"}

Equation mismatch: omc-diff says:
Failed 't' 'f'
Line 1: Text differs:
expected: true
got:      false

== 1 out of 1 tests failed [simulation/modelica/resolveLoops/ElectricalCircuit3.mos_temp8640, time: 0]