Skip to content

Failed

tests / testsuite-clang / simulation_libraries_msl32.Modelica.Magnetic.FundamentalWave.Examples.BasicMachines.SMR_Inverter.mos (from (result.xml))

Failing for the past 9 builds (Since #16 )
Took 1 sec.

Stacktrace

Output mismatch (see stdout for details)

Standard Output

 + Modelica.Magnetic.FundamentalWave.Examples.BasicMachines.SMR_Inverter             ... execution failed

==== Log /tmp/omc-rtest-unknown/simulation/libraries/msl32/Modelica.Magnetic.FundamentalWave.Examples.BasicMachines.SMR_Inverter.mos_temp8338/log-Modelica.Magnetic.FundamentalWave.Examples.BasicMachines.SMR_Inverter.mos
"true
"
""
OpenModelicaModelTesting.Kind.VerifiedSimulation
Modelica.Magnetic.FundamentalWave.Examples.BasicMachines.SMR_Inverter
{"loadInertiaE.phi","loadInertiaE.w","loadInertiaM.phi","loadInertiaM.w","smrE.idq_rr[1]","smrE.idq_rr[2]","smrE.idq_sr[1]","smrE.idq_sr[2]","smrM.stator.electroMagneticConverter.singlePhaseElectroMagneticConverter[1].Phi.re","smrM.stator.electroMagneticConverter.singlePhaseElectroMagneticConverter[2].Phi.im","smrM.stator.strayReluctance.port_p.Phi.im","smrM.stator.strayReluctance.port_p.Phi.re","vfController.x"}
loadModel(Modelica,3.2.1)
/var/lib/jenkins/workspace/OpenModelica_maintenance_v1.13/testsuite/simulation/libraries/msl32/Modelica.Magnetic.FundamentalWave.Examples.BasicMachines.SMR_Inverter.mos_temp8338

== 1 out of 1 tests failed [simulation/libraries/msl32/Modelica.Magnetic.FundamentalWave.Examples.BasicMachines.SMR_Inverter.mos_temp8338, time: 1]