Skip to content

Failed

tests / testsuite-gcc / simulation_libraries_msl22_Electrical.CauerLowPassOPV2.mos (from (result.xml))

Failing for the past 9 builds (Since #16 )
Took 0 ms.

Stacktrace

Output mismatch (see stdout for details)

Standard Output

 + CauerLowPassOPV2                                                                  ... equation mismatch [time: 0]

==== Log /tmp/omc-rtest-unknown/simulation/libraries/msl22/Electrical/CauerLowPassOPV2.mos_temp3381/log-CauerLowPassOPV2.mos
false
record SimulationResult
    resultFile = "",
    simulationOptions = "startTime = 0.0, stopTime = 60.0, numberOfIntervals = 600, tolerance = 1e-06, method = 'dassl', fileNamePrefix = 'Modelica.Electrical.Analog.Examples.CauerLowPassOPV', options = '', outputFormat = 'mat', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "Simulation Failed. Model: Modelica.Electrical.Analog.Examples.CauerLowPassOPV does not exist! Please load it first before simulation."
end SimulationResult;
"R1.v:"



"R1.i:"



"R2.v:"



"R2.i:"



"R3.v:"



"R3.i:"



"R11.v:"



"R11.i:"



"Op1.out.v:"



"Op1.out.i:"



"Op5.out.v:"



"Op5.out.v:"



"C5.v:"



"C5.i:"




Equation mismatch: diff says:
--- /tmp/omc-rtest-unknown/simulation/libraries/msl22/Electrical/CauerLowPassOPV2.mos_temp3381/equations-expected2019-01-31 14:14:07.533718505 +0000
+++ /tmp/omc-rtest-unknown/simulation/libraries/msl22/Electrical/CauerLowPassOPV2.mos_temp3381/equations-got2019-01-31 14:14:07.813717242 +0000
@@ -1,64 +1,62 @@
-true
+false
 record SimulationResult
-resultFile = "Modelica.Electrical.Analog.Examples.CauerLowPassOPV_res.mat",
+resultFile = "",
 simulationOptions = "startTime = 0.0, stopTime = 60.0, numberOfIntervals = 600, tolerance = 1e-06, method = 'dassl', fileNamePrefix = 'Modelica.Electrical.Analog.Examples.CauerLowPassOPV', options = '', outputFormat = 'mat', variableFilter = '.*', cflags = '', simflags = ''",
-messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
-LOG_SUCCESS       | info    | The simulation finished successfully.
-"
+messages = "Simulation Failed. Model: Modelica.Electrical.Analog.Examples.CauerLowPassOPV does not exist! Please load it first before simulation."
 end SimulationResult;
 "R1.v:"
--0.0
--1.0
--1.0
+
+
+
 "R1.i:"
--0.0
--1.0
--1.0
+
+
+
 "R2.v:"
--0.0
-0.0002537404782735835
-0.4993665996062486
+
+
+
 "R2.i:"
--0.0
-0.0002537404782735835
-0.4993665996062486
+
+
+
 "R3.v:"
-0.0
--0.007364533509801463
--0.4997078631745762
+
+
+
 "R3.i:"
-0.0
--0.007364533509801463
--0.4997078631745762
+
+
+
 "R11.v:"
--0.0
--0.000431059983263338
--0.4997076551161084
+
+
+
 "R11.i:"
--0.0
--0.000431059983263338
--0.4997076551161084
+
+
+
 "Op1.out.v:"
--0.0
-0.007364533509801463
-0.4997078631745762
+
+
+
 "Op1.out.i:"
-0.0
--1.215489199613541
--0.001005723078507992
+
+
+
 "Op5.out.v:"
-0.0
-0.000431059983263338
-0.4997076551161084
+
+
+
 "Op5.out.v:"
-0.0
-0.000431059983263338
-0.4997076551161084
+
+
+
 "C5.v:"
--0.0
-0.007364533509801463
-0.4997078631745762
+
+
+
 "C5.i:"
-0.0
-0.200454800416394
-0.0001658608065300561
+
+
+

Equation mismatch: omc-diff says:
Failed 't' 'f'
Line 1: Text differs:
expected: true
got:      false

== 1 out of 1 tests failed [simulation/libraries/msl22/Electrical/CauerLowPassOPV2.mos_temp3381, time: 0]