Skip to content

Failed

tests / testsuite-gcc / simulation_libraries_3rdParty_ThermoSysPro.ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution.mos (from (result.xml))

Failing for the past 6 builds (Since #16 )
Took 0 ms.

Stacktrace

Output mismatch (see stdout for details)

Standard Output

 + ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution.mos [simulation checking]... equation mismatch [time: 0]

==== Log /tmp/omc-rtest-unknown/simulation/libraries/3rdParty/ThermoSysPro/ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution.mos_temp2459/log-ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution.mos
false
"Error: Failed to load package Modelica (3.2.1) using MODELICAPATH /home/jenkins/workspace/OpenModelica_maintenance_v1.13/build/lib/omlibrary.
"
false
"Error: Failed to load package ThermoSysPro (default) using MODELICAPATH /home/jenkins/workspace/OpenModelica_maintenance_v1.13/build/lib/omlibrary.
"
record SimulationResult
    resultFile = "",
    simulationOptions = "startTime = 0.0, stopTime = 1000.0, numberOfIntervals = 500, tolerance = 1e-06, method = 'dassl', fileNamePrefix = 'ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution', options = '', outputFormat = 'mat', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "Simulation Failed. Model: ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution does not exist! Please load it first before simulation."
end SimulationResult;
""
{"Error opening file: /home/jenkins/workspace/OpenModelica_maintenance_v1.13/testsuite/simulation/libraries/3rdParty/ThermoSysPro/ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution.mos_temp2459/ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution_res.mat"}

Equation mismatch: diff says:
--- /tmp/omc-rtest-unknown/simulation/libraries/3rdParty/ThermoSysPro/ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution.mos_temp2459/equations-expected2019-01-25 00:37:40.240076816 +0000
+++ /tmp/omc-rtest-unknown/simulation/libraries/3rdParty/ThermoSysPro/ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution.mos_temp2459/equations-got2019-01-25 00:37:40.312076004 +0000
@@ -1,25 +1,13 @@
-true
-""
-true
-""
+false
+"Error: Failed to load package Modelica (3.2.1) using MODELICAPATH /home/jenkins/workspace/OpenModelica_maintenance_v1.13/build/lib/omlibrary.
+"
+false
+"Error: Failed to load package ThermoSysPro (default) using MODELICAPATH /home/jenkins/workspace/OpenModelica_maintenance_v1.13/build/lib/omlibrary.
+"
 record SimulationResult
-resultFile = "ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution_res.mat",
+resultFile = "",
 simulationOptions = "startTime = 0.0, stopTime = 1000.0, numberOfIntervals = 500, tolerance = 1e-06, method = 'dassl', fileNamePrefix = 'ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution', options = '', outputFormat = 'mat', variableFilter = '.*', cflags = '', simflags = ''",
-messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
-assert            | warning | The following assertion has been violated at time 200.000000
-|                 | |       | staticCentrifugalPumpWaterLiBr.deltaP >= 0.0
-assert            | warning | Variable violating min constraint: 0.0 <= staticCentrifugalPumpWaterLiBr.deltaP, has value: -86.9556
-LOG_SUCCESS       | info    | The simulation finished successfully.
-"
+messages = "Simulation Failed. Model: ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution does not exist! Please load it first before simulation."
 end SimulationResult;
-"[ThermoSysPro 3.1/WaterSolution/Connectors.mo:3:3-43:25:writable] Warning: Connector .ThermoSysPro.WaterSolution.Connectors.WaterSolutionInlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
-[ThermoSysPro 3.1/WaterSolution/Connectors.mo:45:3-85:26:writable] Warning: Connector .ThermoSysPro.WaterSolution.Connectors.WaterSolutionOutlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
-[ThermoSysPro 3.1/WaterSolution/Connectors.mo:3:3-43:25:writable] Warning: Connector .ThermoSysPro.WaterSolution.Connectors.WaterSolutionInlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
-[ThermoSysPro 3.1/WaterSolution/Connectors.mo:45:3-85:26:writable] Warning: Connector .ThermoSysPro.WaterSolution.Connectors.WaterSolutionOutlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
-[ThermoSysPro 3.1/Properties/WaterSteam/Common.mo:703:3-754:22:writable] Warning: pro.x was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
-[ThermoSysPro 3.1/Properties/WaterSteam/Common.mo:1185:3-1241:26:writable] Warning: pro.x was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
-[ThermoSysPro 3.1/WaterSolution/Connectors.mo:45:3-85:26:writable] Warning: Connector .ThermoSysPro.WaterSolution.Connectors.WaterSolutionOutlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
-[ThermoSysPro 3.1/WaterSolution/Connectors.mo:3:3-43:25:writable] Warning: Connector .ThermoSysPro.WaterSolution.Connectors.WaterSolutionInlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
-Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").
-"
-{"Files Equal!"}
+""
+{"Error opening file: /home/jenkins/workspace/OpenModelica_maintenance_v1.13/testsuite/simulation/libraries/3rdParty/ThermoSysPro/ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution.mos_temp2459/ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution_res.mat"}

Equation mismatch: omc-diff says:
Failed 't' 'f'
Line 1: Text differs:
expected: true
got:      false

== 1 out of 1 tests failed [simulation/libraries/3rdParty/ThermoSysPro/ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution.mos_temp2459, time: 0]