Skip to content

Console Output

+ make -C testsuite/special/FmuExportCrossCompile/ test
make: Entering directory '/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile'
rm -rf *.json *.xml *.html *.fmu* *.c *.makefile *.log *.o *.libs *.h *.mat *.csv Test_FMUs
../../../build/bin/omc fmuExportCrossCompile.mos

""

""

""

""
{"x86_64-apple-darwin15 docker run docker.openmodelica.org/osxcross-omsimulator:v2.0","arm-linux-gnueabihf docker run docker.openmodelica.org/armcross-omsimulator:v2.0","x86_64-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13","i686-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13-i386","x86_64-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0","i686-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0"}
FmuExportCrossCompile
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record SimulationResult
    resultFile = "/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 0.45, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'FmuExportCrossCompile', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.673149368,
    timeBackend = 0.004088684,
    timeSimCode = 0.001098543,
    timeTemplates = 0.009412778,
    timeCompile = 0.580836981,
    timeSimulation = 0.030802924,
    timeTotal = 1.299587496
end SimulationResult;
""

"/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile.fmu"


RoomHeating_OM_RH
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: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'RoomHeating_OM_RH', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "assert            | warning | The following assertion has been violated during initialization at time 0.000000
|                 | |       | fanspeed >= 0.01
assert            | warning | UTRC-FCU-002: FCU air damper should be opened at least 0.10.
LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.57678522,
    timeBackend = 0.01309497,
    timeSimCode = 0.002532673,
    timeTemplates = 0.005258109,
    timeCompile = 0.754657433,
    timeSimulation = 0.08448161,
    timeTotal = 1.436943987
end SimulationResult;
"Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").
"

"/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH.fmu"


WaterTank_Control
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record SimulationResult
    resultFile = "/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/WaterTank_Control_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'WaterTank_Control', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.722333705,
    timeBackend = 0.004872492,
    timeSimCode = 0.0009731430000000001,
    timeTemplates = 0.014007017,
    timeCompile = 0.705052343,
    timeSimulation = 0.019750026,
    timeTotal = 1.467151317
end SimulationResult;
""

"/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/WaterTank_Control.fmu"


WaterTank_TestSingleWaterTank

c2beac4c4bb568b0b090c23b88d186b81e8e6d7f6a622bb81d97b815780715d0
be6692de02fd0a022622c43958bfeee714c4489cc72ccb64919427840a621b87
cff6aeba033974cc85e7250ce231b1f77245474257e01a37b8c5596e644fdb4f
1d50002454932b57409e9d1eec751bd60b6e7487e50deb799aa2e479f28efc1e
ad47993ecd3a7d1f0b841fb6027fb0099cad2177d9f0dd28209840182f39e166
60cbaae4671eba5c79e834d802cf26e76c107e09ca12b947d29533f2536d0762
80b2963830e6c2b4ed10577aea74c1ba7d0e4b82b4885baef2c53ea8b51eab12
ae99eeccd430609ec330e9c06e8d5a24aeaef84e3c0e447fd28b2c168de74a64
f2cc9eacbe5097e28d8a1eef26e41e13d043032f4d968c7db818cd924880f830
25e236d7e5067f985af01e643525536e0e117a809447862376c677dfcbc22f17
81c640acbddfff857c0c00ba924030fb977085f8feee643100075f2d75a79e8f
e4f9fe36da65772f2d11e9792900324d39466083901a50a5241505a0b088497a
[/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
[/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'WaterTank_TestSingleWaterTank', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.543911422,
    timeBackend = 0.014139954,
    timeSimCode = 0.004016371,
    timeTemplates = 0.007832072000000001,
    timeCompile = 0.6785632699999999,
    timeSimulation = 0.032232347,
    timeTotal = 1.280871179
end SimulationResult;
"[/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
[/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").
"

"/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank.fmu"



unzip -q FmuExportCrossCompile.fmu -d FmuExportCrossCompile.fmutmp
make check-files
make[1]: Entering directory '/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile'
FmuExportCrossCompile.fmutmp/binaries/win32/FmuExportCrossCompile.dll: PE32 executable (DLL) (console) Intel 80386, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/win64/FmuExportCrossCompile.dll: PE32+ executable (DLL) (console) x86-64, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/darwin64/FmuExportCrossCompile.dylib: Mach-O 64-bit x86_64 dynamically linked shared library, flags:<NOUNDEFS|DYLDLINK|TWOLEVEL|NO_REEXPORTED_DYLIBS>
FmuExportCrossCompile.fmutmp/binaries/linux32/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, Intel 80386, version 1 (SYSV), dynamically linked, BuildID[sha1]=5e1d7ced75230401a91725e47cfe6e8082f4d87b, not stripped
FmuExportCrossCompile.fmutmp/binaries/linux64/FmuExportCrossCompile.so: ELF 64-bit LSB shared object, x86-64, version 1 (SYSV), dynamically linked, BuildID[sha1]=2310bb42dad43638989b186ced673d6c453972e7, not stripped
FmuExportCrossCompile.fmutmp/binaries/arm-linux-gnueabihf/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, ARM, EABI5 version 1 (SYSV), dynamically linked, BuildID[sha1]=879641467618a3f62e2d116baa9ac0cc950c1b45, not stripped
make[1]: Leaving directory '/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile'
make: Leaving directory '/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14/testsuite/special/FmuExportCrossCompile'