Skip to content

Console Output

+ make -C testsuite/special/FmuExportCrossCompile/ test
make: Entering directory '/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_4/testsuite/special/FmuExportCrossCompile'
rm -rf *.json *.xml *.html *.fmu* *.c *.makefile *.log *.o *.libs *.h *.mat *.csv Test_FMUs
../../../build/bin/omc fmuExportCrossCompile.mos

""

""

""

""
{"x86_64-apple-darwin15 docker run docker.openmodelica.org/osxcross-omsimulator:v2.0","arm-linux-gnueabihf docker run docker.openmodelica.org/armcross-omsimulator:v2.0","x86_64-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13","i686-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13-i386","x86_64-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0","i686-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0"}
FmuExportCrossCompile

1fff4c5ff98a08dd1ea4668e6c300438f7f83a80e9edf1181d02f7b323be5875
16b4153025b0a03b29d337f9bdd0ced75af79b2277ebf8cca4f1cd427388b666
b9ab24f2066a2706d16d65386c604ae0729b3bcaf6f5872b6f984b1046ecbe18
ad4177203b97a8fb524bbdf8fac9d5f8afea74810a95a1c75fac49673f0086bb
3447d8bdc271ac6b734d25f4b1f62f68ee66ec99891d5300e33b1633cdeff830
71b85d4129b719913fd9ac1b1ad0f68906c515eca78720cf1c6327420fe53cdb
8023d22169930625f9497e350c110ca9cd606a7e2718240c9692a7ab2243f597
6c392fcff345c1fe24d29d2804a23243695ab431f55d3bcc6e34b5d526c4e063
efb51367936809e9cce988de02c3c0ff46fbcd92f6ce17e6bf6b68b923f2dc24
dec9d0cba958985393c387971a6c529ffb4152c2a615d7a841de5aa67d9d82f8
db293d603bd4724aa1c1e55cc75d1fd84b98279710af61f477468639232b84a7
f7c87c767aa2122f9f6551113b70700e009818748dae579bc92922971908fe2f


record SimulationResult
    resultFile = "/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_4/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 0.45, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'FmuExportCrossCompile', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.4023956999999999,
    timeBackend = 0.003999772,
    timeSimCode = 0.001136832,
    timeTemplates = 0.006462471,
    timeCompile = 0.4611584990000001,
    timeSimulation = 0.02041414,
    timeTotal = 0.895710974
end SimulationResult;
""

"/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_4/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile.fmu"


RoomHeating_OM_RH
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: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_4/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'RoomHeating_OM_RH', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "assert            | warning | The following assertion has been violated during initialization at time 0.000000
|                 | |       | fanspeed >= 0.01
assert            | warning | UTRC-FCU-002: FCU air damper should be opened at least 0.10.
LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.41792057,
    timeBackend = 0.006881037,
    timeSimCode = 0.001542573,
    timeTemplates = 0.007218329000000001,
    timeCompile = 0.4110975419999999,
    timeSimulation = 0.043118525,
    timeTotal = 0.88787656
end SimulationResult;
"Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").
"

"/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_4/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH.fmu"


WaterTank_Control
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record SimulationResult
    resultFile = "/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_4/testsuite/special/FmuExportCrossCompile/WaterTank_Control_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'WaterTank_Control', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.4547425450000001,
    timeBackend = 0.004545706,
    timeSimCode = 0.000927169,
    timeTemplates = 0.109165436,
    timeCompile = 0.658797699,
    timeSimulation = 0.04027411,
    timeTotal = 1.268589641
end SimulationResult;
""

"/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_4/testsuite/special/FmuExportCrossCompile/WaterTank_Control.fmu"


WaterTank_TestSingleWaterTank
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[/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_4/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
[/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_4/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_4/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'WaterTank_TestSingleWaterTank', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.411296255,
    timeBackend = 0.005288650000000001,
    timeSimCode = 0.001324705,
    timeTemplates = 0.003848288,
    timeCompile = 0.46945499,
    timeSimulation = 0.021877945,
    timeTotal = 0.9131656420000001
end SimulationResult;
"[/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_4/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
[/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_4/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").
"

"/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_4/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank.fmu"



unzip -q FmuExportCrossCompile.fmu -d FmuExportCrossCompile.fmutmp
make check-files
make[1]: Entering directory '/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_4/testsuite/special/FmuExportCrossCompile'
FmuExportCrossCompile.fmutmp/binaries/win32/FmuExportCrossCompile.dll: PE32 executable (DLL) (console) Intel 80386, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/win64/FmuExportCrossCompile.dll: PE32+ executable (DLL) (console) x86-64, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/darwin64/FmuExportCrossCompile.dylib: Mach-O 64-bit x86_64 dynamically linked shared library, flags:<NOUNDEFS|DYLDLINK|TWOLEVEL|NO_REEXPORTED_DYLIBS>
FmuExportCrossCompile.fmutmp/binaries/linux32/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, Intel 80386, version 1 (SYSV), dynamically linked, BuildID[sha1]=89de599aebf42854d00de98a0654292a66f1fa89, not stripped
FmuExportCrossCompile.fmutmp/binaries/linux64/FmuExportCrossCompile.so: ELF 64-bit LSB shared object, x86-64, version 1 (SYSV), dynamically linked, BuildID[sha1]=ea66067b920e02964bc88de755228e488511bf5e, not stripped
FmuExportCrossCompile.fmutmp/binaries/arm-linux-gnueabihf/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, ARM, EABI5 version 1 (SYSV), dynamically linked, BuildID[sha1]=bfe4e62118cf7c3ec76709b24a0c7bb24a6805b3, not stripped
make[1]: Leaving directory '/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_4/testsuite/special/FmuExportCrossCompile'
make: Leaving directory '/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_4/testsuite/special/FmuExportCrossCompile'