Skip to content

Console Output

+ make -C testsuite/special/FmuExportCrossCompile/ test
make: Entering directory '/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_4/testsuite/special/FmuExportCrossCompile'
rm -rf *.json *.xml *.html *.fmu* *.c *.makefile *.log *.o *.libs *.h *.mat *.csv Test_FMUs
../../../build/bin/omc fmuExportCrossCompile.mos

""

""

""

""
{"x86_64-apple-darwin15 docker run docker.openmodelica.org/osxcross-omsimulator:v2.0","arm-linux-gnueabihf docker run docker.openmodelica.org/armcross-omsimulator:v2.0","x86_64-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13","i686-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13-i386","x86_64-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0","i686-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0"}
FmuExportCrossCompile
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record SimulationResult
    resultFile = "/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_4/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 0.45, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'FmuExportCrossCompile', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.835001617,
    timeBackend = 0.005830113,
    timeSimCode = 0.001462396,
    timeTemplates = 0.180749159,
    timeCompile = 0.965785671,
    timeSimulation = 0.089708672,
    timeTotal = 2.078740578
end SimulationResult;
""

"/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_4/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile.fmu"


RoomHeating_OM_RH
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: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_4/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'RoomHeating_OM_RH', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "assert            | warning | The following assertion has been violated during initialization at time 0.000000
|                 | |       | fanspeed >= 0.01
assert            | warning | UTRC-FCU-002: FCU air damper should be opened at least 0.10.
LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.617931036,
    timeBackend = 0.014664578,
    timeSimCode = 0.00296302,
    timeTemplates = 0.004227942,
    timeCompile = 0.5650446119999999,
    timeSimulation = 0.063489821,
    timeTotal = 1.268495339
end SimulationResult;
"Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").
"

"/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_4/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH.fmu"


WaterTank_Control
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record SimulationResult
    resultFile = "/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_4/testsuite/special/FmuExportCrossCompile/WaterTank_Control_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'WaterTank_Control', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.913823053,
    timeBackend = 0.006068375,
    timeSimCode = 0.001249078,
    timeTemplates = 0.004365238,
    timeCompile = 0.499190739,
    timeSimulation = 0.019469228,
    timeTotal = 1.444286504
end SimulationResult;
""

"/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_4/testsuite/special/FmuExportCrossCompile/WaterTank_Control.fmu"


WaterTank_TestSingleWaterTank
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[/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_4/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
[/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_4/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_4/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'WaterTank_TestSingleWaterTank', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.743760178,
    timeBackend = 0.015706591,
    timeSimCode = 0.002781639,
    timeTemplates = 0.037845807,
    timeCompile = 0.799049033,
    timeSimulation = 0.108760828,
    timeTotal = 1.708072351
end SimulationResult;
"[/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_4/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
[/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_4/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").
"

"/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_4/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank.fmu"



unzip -q FmuExportCrossCompile.fmu -d FmuExportCrossCompile.fmutmp
make check-files
make[1]: Entering directory '/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_4/testsuite/special/FmuExportCrossCompile'
FmuExportCrossCompile.fmutmp/binaries/win32/FmuExportCrossCompile.dll: PE32 executable (DLL) (console) Intel 80386, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/win64/FmuExportCrossCompile.dll: PE32+ executable (DLL) (console) x86-64, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/darwin64/FmuExportCrossCompile.dylib: Mach-O 64-bit x86_64 dynamically linked shared library, flags:<NOUNDEFS|DYLDLINK|TWOLEVEL|NO_REEXPORTED_DYLIBS>
FmuExportCrossCompile.fmutmp/binaries/linux32/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, Intel 80386, version 1 (SYSV), dynamically linked, BuildID[sha1]=333ff22502c844a29b921b941e97856eb0e02272, not stripped
FmuExportCrossCompile.fmutmp/binaries/linux64/FmuExportCrossCompile.so: ELF 64-bit LSB shared object, x86-64, version 1 (SYSV), dynamically linked, BuildID[sha1]=0364cf6e16cf7f2589ec6bdd038bc8fa765c82b2, not stripped
FmuExportCrossCompile.fmutmp/binaries/arm-linux-gnueabihf/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, ARM, EABI5 version 1 (SYSV), dynamically linked, BuildID[sha1]=cda64a09227d8b127daa64be5072019dd1c40fa4, not stripped
make[1]: Leaving directory '/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_4/testsuite/special/FmuExportCrossCompile'
make: Leaving directory '/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_4/testsuite/special/FmuExportCrossCompile'