Skip to content

Failed

tests / testsuite-gcc / simulation_modelica_arrays.Bug3187.mos (from (result.xml))

Failing for the past 3 builds (Since #1 )
Took 2 sec.

Stacktrace

Output mismatch (see stdout for details)

Standard Output

 + Bug3187.mos                                                                       ... equation mismatch [time: 2]

==== Log /tmp/omc-rtest-unknown/simulation/modelica/arrays/Bug3187.mos_temp6157/log-Bug3187.mos
true
"Notification: Skipped loading package Complex (3.2.1) using MODELICAPATH /var/lib/jenkins2/ws/OpenModelica_maintenance_v1.14_2/build/bin/../lib/omlibrary (uses-annotation may be wrong).
"
record SimulationResult
    resultFile = "PowerSystems.Examples.Spot.AC1ph_DC.Inverter_res.mat",
    simulationOptions = "startTime = 0.0, stopTime = 0.2, numberOfIntervals = 1000, tolerance = 1e-06, method = 'dassl', fileNamePrefix = 'PowerSystems.Examples.Spot.AC1ph_DC.Inverter', options = '', outputFormat = 'mat', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
"
end SimulationResult;
"Notification: Skipped loading package Complex (3.2.1,default) using MODELICAPATH /var/lib/jenkins2/ws/OpenModelica_maintenance_v1.14_2/build/bin/../lib/omlibrary (uses-annotation may be wrong).
"

Equation mismatch: diff says:
--- /tmp/omc-rtest-unknown/simulation/modelica/arrays/Bug3187.mos_temp6157/equations-expected2019-10-27 11:25:08.539901831 +0000
+++ /tmp/omc-rtest-unknown/simulation/modelica/arrays/Bug3187.mos_temp6157/equations-got2019-10-27 11:25:10.967874924 +0000
@@ -1,11 +1,12 @@
 true
-"Notification: Automatically loaded package Complex 3.2.1 due to uses annotation.
+"Notification: Skipped loading package Complex (3.2.1) using MODELICAPATH /var/lib/jenkins2/ws/OpenModelica_maintenance_v1.14_2/build/bin/../lib/omlibrary (uses-annotation may be wrong).
 "
 record SimulationResult
 resultFile = "PowerSystems.Examples.Spot.AC1ph_DC.Inverter_res.mat",
 simulationOptions = "startTime = 0.0, stopTime = 0.2, numberOfIntervals = 1000, tolerance = 1e-06, method = 'dassl', fileNamePrefix = 'PowerSystems.Examples.Spot.AC1ph_DC.Inverter', options = '', outputFormat = 'mat', variableFilter = '.*', cflags = '', simflags = ''",
 messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
 LOG_SUCCESS       | info    | The simulation finished successfully.
 "
 end SimulationResult;
-""
+"Notification: Skipped loading package Complex (3.2.1,default) using MODELICAPATH /var/lib/jenkins2/ws/OpenModelica_maintenance_v1.14_2/build/bin/../lib/omlibrary (uses-annotation may be wrong).
+"

Equation mismatch: omc-diff says:
Failed 'A' 'S'
Line 2: Text differs:
expected: "Notification: Automatically loaded package Complex 
got:      "Notification: Skipped loading package Complex (

== 1 out of 1 tests failed [simulation/modelica/arrays/Bug3187.mos_temp6157, time: 2]