+ make -C testsuite/special/FmuExportCrossCompile/ test
make: Entering directory '/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_4/testsuite/special/FmuExportCrossCompile'
rm -rf *.json *.xml *.html *.fmu* *.c *.makefile *.log *.o *.libs *.h *.mat *.csv Test_FMUs
../../../build/bin/omc fmuExportCrossCompile.mos

""

""

""

""
{"x86_64-apple-darwin15 docker run docker.openmodelica.org/osxcross-omsimulator:v2.0","arm-linux-gnueabihf docker run docker.openmodelica.org/armcross-omsimulator:v2.0","x86_64-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13","i686-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13-i386","x86_64-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0","i686-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0"}
FmuExportCrossCompile
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record SimulationResult
    resultFile = "/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_4/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 0.45, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'FmuExportCrossCompile', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.337298167,
    timeBackend = 0.002504161,
    timeSimCode = 0.0006992820000000001,
    timeTemplates = 0.002698946,
    timeCompile = 0.372763188,
    timeSimulation = 0.018629699,
    timeTotal = 0.734722385
end SimulationResult;
""

"/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_4/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile.fmu"


RoomHeating_OM_RH

f4dbce5c1982346536e1de0d7833e5a9929a42416fed2731fb68ae534bcc3bed
3bf4db22f408e02847249a6347ebc244f6d90f93d2a77859c1beb3bc94a83c3e
953c71b38228a0f250ed7436e077c627391287be4e07313678a7395724cd13b1
77becd176a17622252ba5097b8bc418f0bb06abd1c74f583bc9cec13e8422059
6a881faee03f0c6a97e0fcb9db95466f9dccb9eeb5b393636eb2a647a4f9dc65
b631b9f3cbd01e6ac80b9e40038207d8b1a7d7e9c71de565cb2a43800637af36
7d9254c4da56139487502b24fee38ce08bfba33a53a0e2792545f9e9a714e2f5
70b3de68cac7508e235fc6a4b029d810803d07be49068fe2475132d684615bdc
b002d251d152c9d2e6dfc501c2dfa32e81e4c254305aec17cbcfed37ac88a8b6
74c126a14ca067b192b67b25ee601138ac8513a1d62f9b7347f5f12a3894bd29
8e86f34975910ef3893e836c79f87d09eacfb1675904dc3fca7b8b232b59827a
8b7160003c0e8037e398099724824bcff2fdb9a81244ebdea760d2691422f801
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_4/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'RoomHeating_OM_RH', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "assert            | warning | The following assertion has been violated during initialization at time 0.000000
|                 | |       | fanspeed >= 0.01
assert            | warning | UTRC-FCU-002: FCU air damper should be opened at least 0.10.
LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.3884619549999999,
    timeBackend = 0.006567217,
    timeSimCode = 0.001398706,
    timeTemplates = 0.005047504,
    timeCompile = 0.410521201,
    timeSimulation = 0.037848053,
    timeTotal = 0.8499377809999999
end SimulationResult;
"Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").
"

"/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_4/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH.fmu"


WaterTank_Control
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record SimulationResult
    resultFile = "/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_4/testsuite/special/FmuExportCrossCompile/WaterTank_Control_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'WaterTank_Control', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.367220173,
    timeBackend = 0.002330044,
    timeSimCode = 0.000478018,
    timeTemplates = 0.003320072,
    timeCompile = 0.366305025,
    timeSimulation = 0.015858497,
    timeTotal = 0.7555976599999999
end SimulationResult;
""

"/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_4/testsuite/special/FmuExportCrossCompile/WaterTank_Control.fmu"


WaterTank_TestSingleWaterTank

59b2534f5a01641a83087d9ad310fda14b6a0d2ffa4fa73aed39c0d97eafb239
cbd8d28fb244c45511a72a1162a8b735a1cee7f4e3669381133dcb6e67056e1b
2e422b1864c52a1d6dbb03d969d3c0a60c256249b0ff32de088619e0f0ebdca6
ccecaea1b9601da3732edfc6b82c2354a181f63b8e05288457f331e667ca76bc
dd393876ea8f516063df2a32622f42ac12e1bb9cb21420c397105f256812dde1
8415162240bd810974b6a744a48464042f3b749b5a43021942e58c86fd1b96a7
694d758dddbd432f29481258ca47ecd80879cfc98e4362ec5472dff145db353b
93a5ae7a023ea26a9ec7a1f94d64360a7c3b4875b2a564bf474b84f32ad48923
1c20bf22079e12a73002b5837d5fa85cf181025ba2e393cbfe430c7693b72d3b
f9724a70905c00eb1741d11045fb881603532c18ddf08561156c21ccb65ab232
0ebdf9fd1b468e20ab655cf777cecb8309abbd12890bfb7d0c3cc65f757d88b5
9726be77b76e9cdc35519b1a2958cf301f6be992b361f3fff9524eefd4c7314b
[/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_4/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
[/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_4/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_4/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'WaterTank_TestSingleWaterTank', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.178877734,
    timeBackend = 0.004956323,
    timeSimCode = 0.001217315,
    timeTemplates = 0.004897523,
    timeCompile = 0.3972914279999999,
    timeSimulation = 0.027284404,
    timeTotal = 0.6146166399999999
end SimulationResult;
"[/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_4/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
[/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_4/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").
"

"/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_4/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank.fmu"



unzip -q FmuExportCrossCompile.fmu -d FmuExportCrossCompile.fmutmp
make check-files
make[1]: Entering directory '/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_4/testsuite/special/FmuExportCrossCompile'
FmuExportCrossCompile.fmutmp/binaries/win32/FmuExportCrossCompile.dll: PE32 executable (DLL) (console) Intel 80386, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/win64/FmuExportCrossCompile.dll: PE32+ executable (DLL) (console) x86-64, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/darwin64/FmuExportCrossCompile.dylib: Mach-O 64-bit x86_64 dynamically linked shared library, flags:<NOUNDEFS|DYLDLINK|TWOLEVEL|NO_REEXPORTED_DYLIBS>
FmuExportCrossCompile.fmutmp/binaries/linux32/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, Intel 80386, version 1 (SYSV), dynamically linked, BuildID[sha1]=a1b06032afb2a666a33a5b5ca069e8e283686053, not stripped
FmuExportCrossCompile.fmutmp/binaries/linux64/FmuExportCrossCompile.so: ELF 64-bit LSB shared object, x86-64, version 1 (SYSV), dynamically linked, BuildID[sha1]=901a1fb248b5c003633dffaa9141293a9857534a, not stripped
FmuExportCrossCompile.fmutmp/binaries/arm-linux-gnueabihf/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, ARM, EABI5 version 1 (SYSV), dynamically linked, BuildID[sha1]=45cfd79ec7a9a5968f397863ef9c8513d45f0cb2, not stripped
make[1]: Leaving directory '/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_4/testsuite/special/FmuExportCrossCompile'
make: Leaving directory '/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_4/testsuite/special/FmuExportCrossCompile'