Skip to content

Console Output

+ make -C testsuite/special/FmuExportCrossCompile/ test
make: Entering directory '/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile'
rm -rf *.json *.xml *.html *.fmu* *.c *.makefile *.log *.o *.libs *.h *.mat *.csv Test_FMUs
../../../build/bin/omc fmuExportCrossCompile.mos

""

""

""

""
{"x86_64-apple-darwin15 docker run docker.openmodelica.org/osxcross-omsimulator:v2.0","arm-linux-gnueabihf docker run docker.openmodelica.org/armcross-omsimulator:v2.0","x86_64-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13","i686-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13-i386","x86_64-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0","i686-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0"}
FmuExportCrossCompile
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record SimulationResult
    resultFile = "/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 0.45, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'FmuExportCrossCompile', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 1.020684777,
    timeBackend = 0.00664583,
    timeSimCode = 0.001814181,
    timeTemplates = 0.013456675,
    timeCompile = 0.6457899789999999,
    timeSimulation = 0.029732461,
    timeTotal = 1.71829631
end SimulationResult;
""

"/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile.fmu"


RoomHeating_OM_RH

d30328d4b7d1fe701e3345a474994d066d527eae375170ce1cf523020611b9c3
22eb7f0b3cd4d20f91fdce75787857e79ac71913a627f02eaffd9b7e671cce69
d076bfe7c3107e375e3c77de96c9bda4fc9c92ea5132bb78198237d8c7cce916
a2426493cec250c25b21a4a33964434df3b895d3e56525ad0b6ff9198022ca3f
855e3cebf33873d59a465e914c0880748b08c6f1cf8a17d3b108bd9980c45480
2310ba3ee5ee723c943e211d899a65b7213e313bdec98fe7dd83d0fd8950e3c7
0d91ec716146a458850c38815badcd621614163aab894ac7914d54d6cbbcb526
a16cb431de3c47ab178952b5c61233d9a73049cad31b4ea7a568770e27dd936f
52fb52e010ce33919607b90ebbc330c9d77ea7826f1c714c6b069ca2512b24d5
779223c5518f3a2f73486634434a779a2e6d91938de953663f98d7faeed63f0a
adc22fcd7ab96d63b266e7c4e6cd070557287d5131afb932864eefc589488ef4
625b278ca4dc4c5cb8bcb2aa44f96f2ffa8891001a1fda443c14d91ffeaac5f0
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'RoomHeating_OM_RH', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "assert            | warning | The following assertion has been violated during initialization at time 0.000000
|                 | |       | fanspeed >= 0.01
assert            | warning | UTRC-FCU-002: FCU air damper should be opened at least 0.10.
LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.383381922,
    timeBackend = 0.015857528,
    timeSimCode = 0.00366085,
    timeTemplates = 0.010688427,
    timeCompile = 0.8040808429999999,
    timeSimulation = 0.086041351,
    timeTotal = 1.303865951
end SimulationResult;
"Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").
"

"/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH.fmu"


WaterTank_Control

0272a12f02cfbe165e9d705dae7b94f4b91eb367d51010762db1d9aee19b1139
a3c93824ff8238e05f4e95cbd105f8eb8afa1fbec66d034a85b06c2a85f549d0
0f62968a2ed3aab4d4101cef2744efca4e22b9cc949dd9112bfef1cc0a304c35
a2dbfe69438caf0637e816020bb340b9198f9d2395667efeae799f36e0956d69
aa203e082cf7a96d0f6bcac89f198b93d0ff5b231da3c00f63e14dfbb865a7a8
1d18bd323817c60200fd53d5cc0130adc63a9416961520a931e77319ba8cd8b9
8a8b5939897373f1e680d7f12f266090f124f5cd8bba9c1a624908d635589f97
79d8fa05a1d4bbdfaecd67bf7e6dd227d6072827840d8cda5c464974af2f1f79
bdfa8ba61df4eea4f11843d98f1e0fde3b92eb470105e59dcd5027ee4a653277
5495bad42344322953b8d357c312ce9524b762354c287fcb716cda0ed2575caa
043c4fedf7e0212d00b572a6ba18c35a66a919e477c9be330dcdafd556376854
cf18979e0cffcd6478b610aebc17583f51674e53fe124a52e8920978e7f30782


record SimulationResult
    resultFile = "/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/WaterTank_Control_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'WaterTank_Control', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.351801049,
    timeBackend = 0.007340251999999992,
    timeSimCode = 0.00131352,
    timeTemplates = 0.013295832,
    timeCompile = 0.5837215450000001,
    timeSimulation = 0.029018344,
    timeTotal = 0.98664002
end SimulationResult;
""

"/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/WaterTank_Control.fmu"


WaterTank_TestSingleWaterTank
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[/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
[/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'WaterTank_TestSingleWaterTank', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.363762868,
    timeBackend = 0.009907107,
    timeSimCode = 0.002450609,
    timeTemplates = 0.008144775,
    timeCompile = 0.925126873,
    timeSimulation = 0.037214031,
    timeTotal = 1.346793281
end SimulationResult;
"[/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
[/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").
"

"/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank.fmu"



unzip -q FmuExportCrossCompile.fmu -d FmuExportCrossCompile.fmutmp
make check-files
make[1]: Entering directory '/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile'
FmuExportCrossCompile.fmutmp/binaries/win32/FmuExportCrossCompile.dll: PE32 executable (DLL) (console) Intel 80386, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/win64/FmuExportCrossCompile.dll: PE32+ executable (DLL) (console) x86-64, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/darwin64/FmuExportCrossCompile.dylib: Mach-O 64-bit x86_64 dynamically linked shared library, flags:<NOUNDEFS|DYLDLINK|TWOLEVEL|NO_REEXPORTED_DYLIBS>
FmuExportCrossCompile.fmutmp/binaries/linux32/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, Intel 80386, version 1 (SYSV), dynamically linked, BuildID[sha1]=fa296d17e288f139311061bf716db1121049233e, not stripped
FmuExportCrossCompile.fmutmp/binaries/linux64/FmuExportCrossCompile.so: ELF 64-bit LSB shared object, x86-64, version 1 (SYSV), dynamically linked, BuildID[sha1]=991a80510b90e4a02b12f354cbc09e00796eabd7, not stripped
FmuExportCrossCompile.fmutmp/binaries/arm-linux-gnueabihf/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, ARM, EABI5 version 1 (SYSV), dynamically linked, BuildID[sha1]=14b0ebd87d15246e6af821dab79612bb63b04d55, not stripped
make[1]: Leaving directory '/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile'
make: Leaving directory '/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile'