Skip to content

Console Output

+ make -C testsuite/special/FmuExportCrossCompile/ test
make: Entering directory '/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile'
rm -rf *.json *.xml *.html *.fmu* *.c *.makefile *.log *.o *.libs *.h *.mat *.csv Test_FMUs
../../../build/bin/omc fmuExportCrossCompile.mos

""

""

""

""
{"x86_64-apple-darwin15 docker run docker.openmodelica.org/osxcross-omsimulator:v2.0","arm-linux-gnueabihf docker run docker.openmodelica.org/armcross-omsimulator:v2.0","x86_64-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13","i686-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13-i386","x86_64-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0","i686-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0"}
FmuExportCrossCompile

13f418f74a15f4c906d1b59e99de5e87f48a716423a838a250f4e9503af97cdc
20428a0ebc0ef5e05691f917a92fa06163907b00c16763d1f3b5b198947fb42c
2b1ef1d9d4d8ffc0c07df7f356c8123c7f058ab57c7604ba1d7b234ff979425d
dcf4f704b8c7fd94bc3c967b2726942e63147825fa1536434ff12a4380e8fc84
502bd93b8d5b9b8731f1b00d49e2dda665ea46633a237ecbf0635f8cb5b5a975
44a6686a3544b32ee89180204da6f95a6c7a60bcea8bf2b7a7780a61a96adf03
3b2619d44a5411b8c5237d59043c16a09e74782ea24a74a5f1cddc345860f0ea
637a80b92f116abab4dcd5f1cd41fad66307fbf4e09ac6a003d9b5dc6acda202
68926b32043079a0b2effebfb435bcba6565e5a64c91a16b1a27d829e5868b29
c8f57818a1aa31f7191bfc26007c8b7e5f313cd639a81e2ef8fa663a6af6d807
f39757bd2f866f2574909a2a8f0288d867cebe93dcf6862ec578747c3f947b56
d54d0afc5e5066fc3be4b1b790ceaf1316b952546c1ce3573df518d4e080b600


record SimulationResult
    resultFile = "/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 0.45, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'FmuExportCrossCompile', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.405056882,
    timeBackend = 0.002955734,
    timeSimCode = 0.000844564,
    timeTemplates = 0.007323897,
    timeCompile = 0.481719664,
    timeSimulation = 0.020023016,
    timeTotal = 0.918130986
end SimulationResult;
""

"/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile.fmu"


RoomHeating_OM_RH
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: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'RoomHeating_OM_RH', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "assert            | warning | The following assertion has been violated during initialization at time 0.000000
|                 | |       | fanspeed >= 0.01
assert            | warning | UTRC-FCU-002: FCU air damper should be opened at least 0.10.
LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.762311835,
    timeBackend = 0.011495712,
    timeSimCode = 0.00280425,
    timeTemplates = 0.031600681,
    timeCompile = 0.6686774400000001,
    timeSimulation = 0.074554227,
    timeTotal = 1.551568909
end SimulationResult;
"Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").
"

"/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH.fmu"


WaterTank_Control
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record SimulationResult
    resultFile = "/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/WaterTank_Control_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'WaterTank_Control', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.4903171200000001,
    timeBackend = 0.002902193,
    timeSimCode = 0.0005967790000000001,
    timeTemplates = 0.01550379,
    timeCompile = 0.518101052,
    timeSimulation = 0.018219653,
    timeTotal = 1.045744332
end SimulationResult;
""

"/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/WaterTank_Control.fmu"


WaterTank_TestSingleWaterTank
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[/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
[/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'WaterTank_TestSingleWaterTank', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.318469075,
    timeBackend = 0.011077407,
    timeSimCode = 0.003149638,
    timeTemplates = 0.10418829,
    timeCompile = 0.778963788,
    timeSimulation = 0.086349621,
    timeTotal = 1.302368969
end SimulationResult;
"[/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
[/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation valvecontrol <> 0.0,  <>  on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").
"

"/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank.fmu"



unzip -q FmuExportCrossCompile.fmu -d FmuExportCrossCompile.fmutmp
make check-files
make[1]: Entering directory '/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile'
FmuExportCrossCompile.fmutmp/binaries/win32/FmuExportCrossCompile.dll: PE32 executable (DLL) (console) Intel 80386, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/win64/FmuExportCrossCompile.dll: PE32+ executable (DLL) (console) x86-64, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/darwin64/FmuExportCrossCompile.dylib: Mach-O 64-bit x86_64 dynamically linked shared library, flags:<NOUNDEFS|DYLDLINK|TWOLEVEL|NO_REEXPORTED_DYLIBS>
FmuExportCrossCompile.fmutmp/binaries/linux32/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, Intel 80386, version 1 (SYSV), dynamically linked, BuildID[sha1]=4af37b207e63d377ed40782dcd86f854765d5a6d, not stripped
FmuExportCrossCompile.fmutmp/binaries/linux64/FmuExportCrossCompile.so: ELF 64-bit LSB shared object, x86-64, version 1 (SYSV), dynamically linked, BuildID[sha1]=71cfa805b6f8702da9f513bcbc34e7f74468db32, not stripped
FmuExportCrossCompile.fmutmp/binaries/arm-linux-gnueabihf/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, ARM, EABI5 version 1 (SYSV), dynamically linked, BuildID[sha1]=140324ae35407f274b25e59b42b809e5ccb0d699, not stripped
make[1]: Leaving directory '/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile'
make: Leaving directory '/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.14_2/testsuite/special/FmuExportCrossCompile'