Skip to content

Console Output

+ make -C testsuite/special/FmuExportCrossCompile/ test
make: Entering directory '/var/lib/jenkins1/ws/Modelica_Added-citation-metadata/testsuite/special/FmuExportCrossCompile'
rm -rf *.json *.xml *.html *.fmu* *.c *.makefile *.log *.o *.libs *.h *.mat *.csv Test_FMUs
HOME=/var/lib/jenkins1/ws/Modelica_Added-citation-metadata/testsuite/special/FmuExportCrossCompile/../../libraries-for-testing/ ../../../build/bin/omc fmuExportCrossCompile.mos

""

""

""

""

""
{"x86_64-apple-darwin15 docker run docker.openmodelica.org/osxcross-omsimulator:v2.0","arm-linux-gnueabihf docker run docker.openmodelica.org/armcross-omsimulator:v2.0","x86_64-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13","i686-linux-gnu docker run docker.openmodelica.org/build-deps:v1.13-i386","x86_64-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0","i686-w64-mingw32 docker run docker.openmodelica.org/msyscross-omsimulator:v2.0"}
FmuExportCrossCompile
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record SimulationResult
    resultFile = "/var/lib/jenkins1/ws/Modelica_Added-citation-metadata/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 0.45, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'FmuExportCrossCompile', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.124010774,
    timeBackend = 0.004548318,
    timeSimCode = 0.001394438,
    timeTemplates = 0.06877318,
    timeCompile = 0.672734339,
    timeSimulation = 0.02720994,
    timeTotal = 0.898815232
end SimulationResult;
""

"/var/lib/jenkins1/ws/Modelica_Added-citation-metadata/testsuite/special/FmuExportCrossCompile/FmuExportCrossCompile.fmu"


RoomHeating_OM_RH
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: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->Show additional information from the initialization process, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins1/ws/Modelica_Added-citation-metadata/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'RoomHeating_OM_RH', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "assert            | warning | The following assertion has been violated during initialization at time 0.000000
|                 | |       | fanspeed >= 0.01
assert            | warning | UTRC-FCU-002: FCU air damper should be opened at least 0.10.
LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.39451824,
    timeBackend = 0.019385332,
    timeSimCode = 0.003267045,
    timeTemplates = 0.006297298000000001,
    timeCompile = 0.641092028,
    timeSimulation = 0.062195482,
    timeTotal = 1.126859821
end SimulationResult;
"Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->Show additional information from the initialization process, in OMNotebook call setCommandLineOptions(\"-d=initialization\").
"

"/var/lib/jenkins1/ws/Modelica_Added-citation-metadata/testsuite/special/FmuExportCrossCompile/RoomHeating_OM_RH.fmu"


WaterTank_Control
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: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->Show additional information from the initialization process, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins1/ws/Modelica_Added-citation-metadata/testsuite/special/FmuExportCrossCompile/WaterTank_Control_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'WaterTank_Control', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.09054129100000001,
    timeBackend = 0.002487477,
    timeSimCode = 0.000824487,
    timeTemplates = 0.003628258,
    timeCompile = 0.5345900859999999,
    timeSimulation = 0.022777552,
    timeTotal = 0.654958207
end SimulationResult;
"Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->Show additional information from the initialization process, in OMNotebook call setCommandLineOptions(\"-d=initialization\").
"

"/var/lib/jenkins1/ws/Modelica_Added-citation-metadata/testsuite/special/FmuExportCrossCompile/WaterTank_Control.fmu"


WaterTank_TestSingleWaterTank
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[/var/lib/jenkins1/ws/Modelica_Added-citation-metadata/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation tank.valvecontrol <> 0.0, <> on Real numbers is only allowed inside functions.
[/var/lib/jenkins1/ws/Modelica_Added-citation-metadata/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation tank.valvecontrol <> 0.0, <> on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->Show additional information from the initialization process, in OMNotebook call setCommandLineOptions("-d=initialization").


record SimulationResult
    resultFile = "/var/lib/jenkins1/ws/Modelica_Added-citation-metadata/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'WaterTank_TestSingleWaterTank', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.09198571800000001,
    timeBackend = 0.008492876,
    timeSimCode = 0.001985464,
    timeTemplates = 0.003445057,
    timeCompile = 0.61194024,
    timeSimulation = 0.036107177,
    timeTotal = 0.754050702
end SimulationResult;
"[/var/lib/jenkins1/ws/Modelica_Added-citation-metadata/testsuite/special/FmuExportCrossCompile/WaterTank.mo:44:2-44:68:writable] Warning: In relation tank.valvecontrol <> 0.0, <> on Real numbers is only allowed inside functions.
[/var/lib/jenkins1/ws/Modelica_Added-citation-metadata/testsuite/special/FmuExportCrossCompile/WaterTank.mo:46:2-46:70:writable] Warning: In relation tank.valvecontrol <> 0.0, <> on Real numbers is only allowed inside functions.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->Show additional information from the initialization process, in OMNotebook call setCommandLineOptions(\"-d=initialization\").
"

"/var/lib/jenkins1/ws/Modelica_Added-citation-metadata/testsuite/special/FmuExportCrossCompile/WaterTank_TestSingleWaterTank.fmu"


BouncingBall

5adf4820fde6bcf030d70a7bca52211d9f23bfc4ceaa53b8bae7682c7da5c381
72cabdb0a754a458280d7b37c00f0af27c3d4c84e71f4d28650c6fa564be109f
e780e3b7ba6fbc24978199e2f223ac48432e2231103ce1730eaad49d849b2dfb
dbe386c7911cfd49e92dd3fbe5479be7276b4701094ba7d172c7af95fc72a506
6d896083f283e899bac8563657a83afab6415ceed244e870bb99f4e71d13ea48
b4b8aeb386cdbce794a02a1176a569b8a14ea155a234f1b5d6e1245321c963c5
70541c5afdd358232afb384710ec92c44637d15f32788462c7345937549e80ae
8b3595f19f5616139f71940e86f0eb6d2f17adea629535bb4f15bb21debf967e
5d8ee7000c0ced6e3fa92f68547c863dfbbcdaf8bc8534029f27bca11385a5ee
0b71688f16f67416aff7bebac85b181202cb2dbc7cec3c8ef928639f7bd4dff2
8f8561faa730e3674c8332e238cc64ede53241b7b7d713ea5d031640956b4a78
f0f76901f0ddfdd3d0881c1f73326d14c7b6e31e689cde286acbabf94e8e6602


record SimulationResult
    resultFile = "/var/lib/jenkins1/ws/Modelica_Added-citation-metadata/testsuite/special/FmuExportCrossCompile/BouncingBall_res.csv",
    simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 2000, tolerance = 1e-06, method = 'euler', fileNamePrefix = 'BouncingBall', options = '', outputFormat = 'csv', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
",
    timeFrontend = 0.1100808139999999,
    timeBackend = 0.006110898,
    timeSimCode = 0.001904172,
    timeTemplates = 0.003123198,
    timeCompile = 0.523372566,
    timeSimulation = 0.025804002,
    timeTotal = 0.670491721
end SimulationResult;
""

"/var/lib/jenkins1/ws/Modelica_Added-citation-metadata/testsuite/special/FmuExportCrossCompile/BouncingBall.fmu"



unzip -q FmuExportCrossCompile.fmu -d FmuExportCrossCompile.fmutmp
make check-files
make[1]: Entering directory '/var/lib/jenkins1/ws/Modelica_Added-citation-metadata/testsuite/special/FmuExportCrossCompile'
FmuExportCrossCompile.fmutmp/binaries/win32/FmuExportCrossCompile.dll: PE32 executable (DLL) (console) Intel 80386, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/win64/FmuExportCrossCompile.dll: PE32+ executable (DLL) (console) x86-64, for MS Windows
FmuExportCrossCompile.fmutmp/binaries/darwin64/FmuExportCrossCompile.dylib: Mach-O 64-bit x86_64 dynamically linked shared library, flags:<NOUNDEFS|DYLDLINK|TWOLEVEL|NO_REEXPORTED_DYLIBS>
FmuExportCrossCompile.fmutmp/binaries/linux32/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, Intel 80386, version 1 (SYSV), dynamically linked, BuildID[sha1]=c71f1bfb38a9a245444161de691762a082af57b1, not stripped
FmuExportCrossCompile.fmutmp/binaries/linux64/FmuExportCrossCompile.so: ELF 64-bit LSB shared object, x86-64, version 1 (SYSV), dynamically linked, BuildID[sha1]=ead51bdac7db9890bd7e2bbc58d8def6d23df227, not stripped
FmuExportCrossCompile.fmutmp/binaries/arm-linux-gnueabihf/FmuExportCrossCompile.so: ELF 32-bit LSB shared object, ARM, EABI5 version 1 (SYSV), dynamically linked, BuildID[sha1]=0678f63ecd94d2ddc3198ddc62974bf08c43f2de, not stripped
make[1]: Leaving directory '/var/lib/jenkins1/ws/Modelica_Added-citation-metadata/testsuite/special/FmuExportCrossCompile'
make: Leaving directory '/var/lib/jenkins1/ws/Modelica_Added-citation-metadata/testsuite/special/FmuExportCrossCompile'