Recursive BuildModel Test

BuildModel Results: 83/83 succeeded

Simulation Results: 82/83 succeeded

Total time taken: 393.1

OpenModelica Version: OMCompiler v1.13.0-dev.63+g453e1c7

Test started: 2017-10-02 07:51:58

Tested Library: ThermoSysPro 3.1( revision 3.1+OSR-18-gdb81ae1 )

BuildModel time limit: 660s

Simulation time limit: 480s

Default tolerance: 1e-06

Flags:
setCommandLineOptions("-d=nogen,initialization,backenddaeinfo,discreteinfo,stateselection,execstat");
setMatchingAlgorithm("PFPlusExt");
setIndexReductionMethod("dynamicStateSelection");

Links are provided if getErrorString() or the simulation generates output. The links are coded with red if there were errors, yellow if there were warnings, and normal links if there are only notifications.

Green cells means success. Red is bad and in general signifies a failure.

ModelSimulateTotal buildModelFrontendBackendSimCodeTemplatesCompile
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50 (sim)23493.1917.3737.853.2649.1225.61
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC (sim)29089.5316.8135.774.4457.73324.78
ThermoSysPro.Examples.SimpleExamples.TestAirHumidity (sim)0.18047.7914.0030.10320.019330.087093.625
ThermoSysPro.Examples.SimpleExamples.TestBend (sim)0.137410.372.9913.2530.026680.78393.333
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump (sim)2.0749.3242.7432.0650.051620.12664.355
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1 (sim)0.37269.3472.6712.3320.038190.23294.091
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump10 (sim)0.470810.192.7153.3330.031450.15753.969
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump11 (sim)0.739310.92.8113.6580.64730.15123.668
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump12 (sim)1.7748.8173.1451.6870.025750.1743.802
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump13 (sim)1.6288.0442.3861.6650.026310.11913.865
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump2 (sim)1.3899.1682.4183.1460.032860.12593.464
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump3 (sim)4.2638.1792.5841.3770.044420.16814.025
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump4 (sim)3.1967.8442.4251.3690.04240.37143.656
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump5 (sim)1.5787.3812.2351.6110.030730.11373.416
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump6 (sim)1.49910.82.6673.2330.031870.2114.678
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump7 (sim)20.6211.613.0014.350.053390.18174.057
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump8 (sim)0.22619.2372.7841.8430.042440.15864.449
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump9 (sim)0.18288.7663.161.430.029760.11224.053
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPumpWaterSolution (sim)0.1136.1551.9350.14920.076820.056453.955
ThermoSysPro.Examples.SimpleExamples.TestCheckValve (sim)3.87112.533.2493.3060.074740.21455.715
ThermoSysPro.Examples.SimpleExamples.TestCompressor (sim)0.089289.5453.3831.8150.039020.3074.019
ThermoSysPro.Examples.SimpleExamples.TestControlValve (sim)0.12459.5152.63.110.021710.27343.527
ThermoSysPro.Examples.SimpleExamples.TestDiaphragm (sim)0.18079.352.5652.9440.021050.46463.373
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump (sim)4.6678.2062.7381.7450.039870.13263.598
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump1 (sim)5.0948.7742.1941.350.036320.13745.11
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump2 (sim)12.3111.612.6063.9170.046950.16374.9
ThermoSysPro.Examples.SimpleExamples.TestDynamicCheckValve (sim)0.7949.7992.5412.8110.041280.29744.145
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum (sim)11.0919.153.6797.1720.59131.0476.682
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum1 (sim)11.2519.514.4757.1510.53170.91776.455
ThermoSysPro.Examples.SimpleExamples.TestDynamicOnePhaseFlowPipe (sim)2.812.193.3482.4450.16540.51815.745
ThermoSysPro.Examples.SimpleExamples.TestDynamicReliefValve (sim)6.1539.3252.3583.5230.038440.14293.283
ThermoSysPro.Examples.SimpleExamples.TestDynamicTwoPhaseFlowPipe (sim)4.65916.483.4585.1980.35180.91646.572
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating (sim)34.7835.595.69415.951.0272.76710.17
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterWaterExchanger (sim)1.94310.222.9531.9650.086490.2734.987
ThermoSysPro.Examples.SimpleExamples.TestFan (sim)4.1967.913.180.38470.04210.12194.202
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesJunctions (sim)0.23016.8012.7760.2620.020640.10433.658
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes (sim)1.2547.0662.6930.41660.050.38133.557
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes1 (sim)0.32026.6492.7670.30260.022910.075643.499
ThermoSysPro.Examples.SimpleExamples.TestIdealCheckValve (sim)2.98610.382.7993.630.051010.21853.702
ThermoSysPro.Examples.SimpleExamples.TestIdealSwitchValve (sim)0.23029.0912.2562.6880.030390.78143.354
ThermoSysPro.Examples.SimpleExamples.TestInvSingularPressureLoss (sim)0.09718.4022.3312.6260.019670.31733.346
ThermoSysPro.Examples.SimpleExamples.TestJunctions (sim)0.91429.9262.2733.2090.05620.17864.276
ThermoSysPro.Examples.SimpleExamples.TestJunctions2 (sim)1.09610.612.4373.3770.054980.19234.576
ThermoSysPro.Examples.SimpleExamples.TestJunctions3 (sim)58.479.922.8093.4920.07440.17233.436
ThermoSysPro.Examples.SimpleExamples.TestJunctions4 (sim)0.376710.382.4274.3290.02890.11933.496
ThermoSysPro.Examples.SimpleExamples.TestJunctions5 (sim)4.0389.9512.5373.5480.058790.19933.627
ThermoSysPro.Examples.SimpleExamples.TestLoopBreaker (sim)0.32847.0632.0171.7610.024770.1083.17
ThermoSysPro.Examples.SimpleExamples.TestLumpedStraightPipe (sim)4.1329.1282.3592.5590.034880.51943.675
ThermoSysPro.Examples.SimpleExamples.TestMassFlowMultiplier (sim)0.30658.8462.1021.8280.024430.10874.814
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating0 (sim)1.69612.43.0484.7290.05340.26694.317
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating1 (sim)21.610.382.3223.2320.11480.36314.368
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating2 (sim)77.5510.42.6743.5430.077430.27413.86
ThermoSysPro.Examples.SimpleExamples.TestPipePressureLoss (sim)0.12889.1242.3843.2630.068750.099013.405
ThermoSysPro.Examples.SimpleExamples.TestRefP (sim)0.27147.2892.4221.4610.025730.11663.282
ThermoSysPro.Examples.SimpleExamples.TestSensors (sim)0.29729.3422.2672.5570.037560.74133.783
ThermoSysPro.Examples.SimpleExamples.TestSimpleEvaporatorWaterSteamFlueGases (sim)0.41699.6124.3731.2830.02720.50693.443
ThermoSysPro.Examples.SimpleExamples.TestSimpleStaticCondenser (sim)0.61177.6172.4861.6060.030240.19523.318
ThermoSysPro.Examples.SimpleExamples.TestSingularPressureLoss (sim)0.11869.1162.3032.5020.020030.62623.683
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump (sim)1.2057.2652.0941.7870.085610.11673.207
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump1 (sim)0.12168.8972.3972.6460.022890.6873.164
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump2 (sim)1.9337.1362.1121.5670.033040.12663.318
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution (sim)0.062714.671.5350.080730.085250.067052.928
ThermoSysPro.Examples.SimpleExamples.TestStaticCondenser (sim)1.5669.8492.3583.4320.051810.18873.85
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum1 (sim)0.58889.3032.282.5620.031610.79653.65
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum2 (sim)0.60418.212.2212.5720.028180.23973.166
ThermoSysPro.Examples.SimpleExamples.TestStaticExchangerWaterSteamFlueGases (sim)0.442410.064.2971.2130.027290.25594.307
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchanger (sim)0.30978.1972.7131.7420.037850.17363.548
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchangerDTorWorEff (sim)0.56479.9022.5812.2640.032830.13974.911
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer (sim)0.50210.732.4313.9150.029170.20634.173
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer2 (sim)0.575110.672.6413.1580.029250.11774.743
ThermoSysPro.Examples.SimpleExamples.TestSteamEngine (sim)0.29610.133.3972.6370.029930.15053.932
ThermoSysPro.Examples.SimpleExamples.TestSteamExtractionSplitter (sim)0.55379.0362.5362.690.02930.12563.675
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine (sim)2.88811.93.2664.5730.048850.18193.853
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine1 (sim)0.967512.233.1755.1770.043280.16523.688
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine2 (sim)0.353210.163.0093.3880.032150.29663.451
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine3 (sim)0.693911.13.1073.9590.19750.17013.68
ThermoSysPro.Examples.SimpleExamples.TestSwitchValve (sim)0.17778.1652.252.5170.024280.24823.154
ThermoSysPro.Examples.SimpleExamples.TestTank (sim)1.7049.4672.4313.3880.032790.19233.442
ThermoSysPro.Examples.SimpleExamples.TestThreeWayValve (sim)0.79459.3722.662.9270.05160.13413.634
ThermoSysPro.Examples.SimpleExamples.TestVolumes (sim)4.90910.42.7313.6330.058550.19653.795
ThermoSysPro.Examples.SimpleExamples.TestVolumes1 (sim)5.08610.282.8933.2880.055180.18813.873
ThermoSysPro.Examples.SimpleExamples.TestVolumes2 (sim)17.239.8962.6413.3540.048950.19163.682
ThermoSysPro.Examples.SimpleExamples.TestWaterHammer (sim) 10.713.0193.5030.14920.20773.851

Offline version