Recursive BuildModel Test

BuildModel Results: 83/83 succeeded

Simulation Results: 82/83 succeeded

Total time taken: 449

OpenModelica Version: OMCompiler v1.12.0-dev.569+g2eed74c

Test started: 2017-08-05 07:19:57

Tested Library: ThermoSysPro 3.1( revision 3.1+OSR-18-gdb81ae1 )

BuildModel time limit: 660s

Simulation time limit: 480s

Default tolerance: 1e-06

Flags:
setCommandLineOptions("-d=nogen,initialization,backenddaeinfo,discreteinfo,stateselection,execstat");
setMatchingAlgorithm("PFPlusExt");
setIndexReductionMethod("dynamicStateSelection");

Links are provided if getErrorString() or the simulation generates output. The links are coded with red if there were errors, yellow if there were warnings, and normal links if there are only notifications.

Green cells means success. Red is bad and in general signifies a failure.

ModelSimulateTotal buildModelFrontendBackendSimCodeTemplatesCompile
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50240.291.0217.535.324.0038.95425.27
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC (sim)333.690.8917.3736.063.5838.19625.71
ThermoSysPro.Examples.SimpleExamples.TestAirHumidity0.097886.9143.7260.10070.015840.087863.004
ThermoSysPro.Examples.SimpleExamples.TestBend0.17099.052.6022.9020.10750.21813.24
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1.9898.4883.0831.7270.045480.13263.52
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump10.33558.042.4381.8020.039790.13493.645
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump100.53119.8042.9543.3520.076180.14043.302
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump11 (sim)0.67410.163.3983.2050.032750.2333.31
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump12 (sim)1.1767.4612.4341.7610.034690.10493.158
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump130.47947.1812.391.4350.025320.10373.246
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump21.349.2462.742.9340.03320.13093.43
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump3 (sim)4.6167.1962.2361.4590.047750.18043.349
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump43.447.4322.361.4980.042430.14093.412
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump51.697.372.1131.7520.030310.15423.341
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump61.5539.4422.5843.1630.036990.18583.491
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump7 (sim)66.439.5582.6133.0580.055590.18153.671
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump8 (sim)0.26817.8312.4622.0180.027490.18133.162
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump9 (sim)0.17677.4642.1862.0310.027260.11213.135
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPumpWaterSolution0.10284.9431.6930.090880.082960.067053.033
ThermoSysPro.Examples.SimpleExamples.TestCheckValve3.69310.732.6263.6060.054080.21344.251
ThermoSysPro.Examples.SimpleExamples.TestCompressor (sim)0.088299.0253.4391.3020.035110.79393.5
ThermoSysPro.Examples.SimpleExamples.TestControlValve0.13719.8492.5882.9410.052920.84283.489
ThermoSysPro.Examples.SimpleExamples.TestDiaphragm0.16319.2862.8692.6830.026270.23633.493
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump (sim)4.2227.7172.5281.7090.033270.12253.344
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump1 (sim)4.2567.922.3621.5430.040970.19943.792
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump2 (sim)374.310.462.6783.4610.083460.19274.07
ThermoSysPro.Examples.SimpleExamples.TestDynamicCheckValve0.65459.8712.3272.9050.58920.20523.863
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum10.2619.0647.2360.38961.2086.244
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum111.1319.134.2437.4880.39720.94386.081
ThermoSysPro.Examples.SimpleExamples.TestDynamicOnePhaseFlowPipe2.59811.093.3162.6130.2650.55914.355
ThermoSysPro.Examples.SimpleExamples.TestDynamicReliefValve (sim)6.8479.0922.7792.8570.042420.14953.285
ThermoSysPro.Examples.SimpleExamples.TestDynamicTwoPhaseFlowPipe4.48918.574.4255.7260.33961.8686.233
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating (sim)35.4737.135.82517.381.1432.72410.07
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterWaterExchanger1.47610.362.9832.2580.13990.94194.067
ThermoSysPro.Examples.SimpleExamples.TestFan3.4326.3572.5880.34940.037740.16243.245
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesJunctions0.17696.882.7020.094620.15660.066673.881
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes0.83487.4253.2810.26220.039320.21473.648
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes10.23066.2962.8290.12820.024030.078113.256
ThermoSysPro.Examples.SimpleExamples.TestIdealCheckValve (sim)5.30710.963.0483.8740.059770.20983.792
ThermoSysPro.Examples.SimpleExamples.TestIdealSwitchValve0.72258.9732.4553.0970.028450.12543.287
ThermoSysPro.Examples.SimpleExamples.TestInvSingularPressureLoss0.10869.2352.4952.5340.019770.76353.443
ThermoSysPro.Examples.SimpleExamples.TestJunctions0.63479.6252.4393.5930.048010.17493.39
ThermoSysPro.Examples.SimpleExamples.TestJunctions21.08110.062.7143.5120.05550.20653.587
ThermoSysPro.Examples.SimpleExamples.TestJunctions3 (sim)55.259.4842.5773.0920.046570.17363.616
ThermoSysPro.Examples.SimpleExamples.TestJunctions40.375310.272.6064.2290.028790.12573.301
ThermoSysPro.Examples.SimpleExamples.TestJunctions55.08510.072.5073.5420.059260.23273.745
ThermoSysPro.Examples.SimpleExamples.TestLoopBreaker0.3537.4442.2491.8440.025440.10663.238
ThermoSysPro.Examples.SimpleExamples.TestLumpedStraightPipe4.3089.6682.3183.4130.035860.143.78
ThermoSysPro.Examples.SimpleExamples.TestMassFlowMultiplier0.3657.3492.2191.8440.02290.10383.179
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating0 (sim)1.76910.912.1824.8130.047230.19783.696
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating1 (sim)22.88.9082.2812.8090.049080.17513.615
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating276.5910.122.5553.3370.12270.25443.868
ThermoSysPro.Examples.SimpleExamples.TestPipePressureLoss0.19978.4752.372.6050.033130.23793.248
ThermoSysPro.Examples.SimpleExamples.TestRefP0.22157.3272.3961.4690.025770.11623.343
ThermoSysPro.Examples.SimpleExamples.TestSensors0.2638.9122.5222.7740.025050.13463.477
ThermoSysPro.Examples.SimpleExamples.TestSimpleEvaporatorWaterSteamFlueGases0.39049.8384.2831.330.025070.26553.952
ThermoSysPro.Examples.SimpleExamples.TestSimpleStaticCondenser0.60878.0122.5061.6290.02990.1343.733
ThermoSysPro.Examples.SimpleExamples.TestSingularPressureLoss0.14688.6412.5472.6930.023650.24643.152
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump (sim)1.1757.2492.2321.4530.030690.13123.425
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump10.10849.0212.4092.6580.023930.80853.14
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump21.797.3112.3191.5380.031390.11723.333
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution (sim)0.072734.8121.6660.077260.086350.058052.943
ThermoSysPro.Examples.SimpleExamples.TestStaticCondenser (sim)5.62810.152.5063.3730.051690.20164.037
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum10.54899.1762.3032.6510.033140.70413.506
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum20.62849.4242.3962.8690.037110.73443.423
ThermoSysPro.Examples.SimpleExamples.TestStaticExchangerWaterSteamFlueGases0.35119.4784.2091.1920.027570.25953.81
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchanger0.32238.5192.5521.7090.034630.7513.492
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchangerDTorWorEff0.59867.682.5231.6640.047010.13553.36
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer0.58799.2052.6093.0430.040950.24783.309
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer2 (sim)0.57269.0752.2082.70.031240.78633.369
ThermoSysPro.Examples.SimpleExamples.TestSteamEngine0.35119.2513.1252.3880.031730.14253.583
ThermoSysPro.Examples.SimpleExamples.TestSteamExtractionSplitter0.54999.4492.7243.1920.028410.14053.383
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine3.06914.083.1494.6270.065680.18636.082
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine11.00213.363.2295.5810.041830.18484.346
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine20.396811.233.4193.9420.037570.33223.513
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine30.621412.43.6324.770.051770.17833.784
ThermoSysPro.Examples.SimpleExamples.TestSwitchValve0.19419.1952.8332.9130.021180.25813.19
ThermoSysPro.Examples.SimpleExamples.TestTank1.7639.232.5253.1030.031810.12413.468
ThermoSysPro.Examples.SimpleExamples.TestThreeWayValve (sim)0.74529.9262.6513.7810.03130.13033.353
ThermoSysPro.Examples.SimpleExamples.TestVolumes5.56410.162.8293.5840.05510.19443.524
ThermoSysPro.Examples.SimpleExamples.TestVolumes15.42810.22.7053.6950.06790.26363.491
ThermoSysPro.Examples.SimpleExamples.TestVolumes2 (sim)18.419.8452.7183.3560.05520.2043.532
ThermoSysPro.Examples.SimpleExamples.TestWaterHammer (sim) 9.9242.733.3830.096040.29563.442

Offline version